Operating Instructions for the DA 337 i Ventilation System ö] To prevent accidents and machine damage, read these Operating Instructions installation or use. M.-Nr. 05 473 690...
Page 3
Caring for the environment The transport and protective packing are environmentally friendly for dispo- sal and can normally be recycled. Please recycle. Old appliances contain materials that can be recycled. Please contact your local recycling center about the possi- bility of recycling these materials. Make sure that the appliance presents no danger to children while waiting for disposal by removing the power cord...
Page 4
– For electric cooktops: 18" (45 cm) – For gas cooktops: – For a Miele open grill: 26" (65 cm) Do not install this exhaust hood over cooktops burning solid fuel. 26" (65 cm)
Page 5
Any fittings, sealant, or materials used to install the ductwork must be made of approved non-flammable materials. Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room ventilating ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, in- active chimney or vent flue.
Page 6
with a close fit- ting lid, cookie sheet, or metal tray, then turn off the burner. If the flames do not go out immediately, You may be burned. , including wet dishcloths or towels - a violent steam explosion will occur. –...
Page 7
When connecting the hood to an ex- ternal vent, make sure that there is adequate ventilation in the room where the exhaust hood is to be used. When using the hood in the same area as other appliances requiring room air (e.g.
Page 9
(Four fan speed selection) This control activates the Delayed Shut Down feature. The fan turns off auto- matically after either 5 or 15 minutes. The indicator next to the grease filter button lights up when the grease filter needs to be cleaned. Use this button to: –...
Page 10
Description of the functions The hood works The air is drawn in, cleaned by an exter- nal filter and then passed through an in- ternal filter before being directed out- side. The hood has a "Installation"). This flap is closed when the hood is off.
Page 11
Operation Pull the deflector plate out about 2” (5 cm). The hood will then begin to operate at power level ”II”. Depending on how much the air needs to be filtered, there are four power le- vels available. For normal cooking a low to medium level is usually suffi- cient.
Page 12
Use the On/Off button to turn the fan Push the deflector plate back in. The next time the deflector plate is pulled out the hood will operate at power level ”II”. The overhead lighting for the cooktop can be turned on or off independently of the fan.
Page 13
The timer for the grease filters is preset for 30 hours of use. After 30 hours the grease filter indicator will light. The grease filters must be cleaned at this time, and reset as follows: Hold the grease filter button for 4 seconds.
Page 14
You can set the filter timer to suit the type of cooking you do. – Select a short time if you grill or fry frequently. – Select a longer time if you do not grill or fry often. – if you only cook occasionally, pro- gram a shorter time so the filters will be cleaned more often.
Page 15
The active charcoal filter is needed for recirculation mode. It is not used for vented extraction. The hood is preset for vented extrac- tion, the filter hour counter for the ac- tive charcoal filter is set to ”unlimited”. For recirculation mode the filter timer needs to be set to the required time: Use the On/Off button to turn the fan off.
Page 16
Cleaning and care Before servicing or cleaning the hood, disconnect it from the power supply by either removing the fuse, unplugging it, or manually ”tripping” the circuit breaker. Ensure current is not supplied to the appliance while maintenance or re- pair work is performed.
Page 17
To remove the external filter pull the deflector plate out slightly. Turn the fan off. Holding the external filter at the front tilt it approximately 1” (3 cm) down- wards and then pull it towards you to remove it. Pull the deflector plate out to its full extension.
Page 18
Internal filter: Insert the filter into the hood so that it hooks into position at the back, then push it upwards at the front and make sure it engages in position on the left and right hand sides. Twist the grease filter catch as shown.
Page 19
The active charcoal filter is inserted into a slot on the front of the appliance housing. Replacement active charcoal filters can be ordered from the Miele Tech- nical Service Department at 1-800-999-1360. Please quote part number 28 9961 34...
Page 20
Before changing the light bulbs, dis- connect the hood from the power supply by either removing the fuse, unplugging it, or manually ”tripping” the circuit breaker. Make sure that power is not re- stored to the appliance while main- tenance or repair work is performed. When in use the halogen bulbs become extremely hot and can cause burns.
Page 21
After Sales Service In the event of a problem which you can not fix yourself, please contact: – Your Miele dealer – The Miele Technical Service Depart- ment, (see address on back cover). When contacting the Technical Service Department, please quote the model...
Page 23
– 18” (450 mm) above electric cooktop – 26” (650 mm) above gas cooktops – 26” (650 mm) above a Miele open grill A distance of 26” (650 mm) is rec- ommended for all installations to allow more work space under the hood.
Page 24
Miele Technical Service Department in the appropriate width to suit the cabinet (Miele DT 60, DT 70). Millimeters ....Inches 10 ......3 /8 15 .
Page 27
for securing the vent ducting to the vent connection. for exhaust ducting of a 5” (125 mm). for fitting into the vent connection. (1 x right, 1x left) to support the ap- pliance in the cabinet. for installing the appliance in a 27 (70 cm) wide cabinet.
Page 28
1. Non-return flap (if needed) 2. Reducing collar (if needed) 3. Fit the runners in the cabinet 4. Hang and align the cabinet door 5. Position the appliance in the cabinet 6. Align the height of the appliance 7. Align the depth of the appliance 8.
Page 29
The appliance is designed for vent ducting 6” (150 mm) diameter. If a 5” (125 mm) diameter is required: Place the reducing collar supplied on the vent socket and turn it to se- cure it in position (see ”Connection for air extraction”). Place the reducing collar for a 5”...
Page 30
(Standard cabinet: 23 wide, 16 mm thick cabinet wall sides) Hold the runner against the cabinet so that the lower edge of the runner is flush with the cabinet. The first row of screws must be aligned with the pencil marks. The ”16 mm"...
Page 31
Lift the venting hood into the cabinet, making sure that the supports on the venting hood are sitting on the run- ners in the cabinet. Push it into the cabinet as far as it will go. The supports will slide under the anti- tip device Insert the adjusting screws on the...
Page 32
To move the appliance further out of the cabinet: Loosen screws and tighten screws Tighten screws again to secure it into position. To move the appliance further into the cabinet: Loosen screws and tighten screws Tighten screws again to secure it in position.
Page 33
Measure the gap ”T” to be covered between the rear of the appliance and the wall. Use a knife to trim the spacer strip supplied to measurement ”T”. Stick the spacer strip to the under- side of the appliance. Turn the side cover caps upwards and press into position.
Page 34
If the hood can not be installed for air extraction the appliance must be con- nected for recirculation. The following parts, available through your Miele Dealer or from the Miele Technical Service Department are necessary for using the appliance in re- circulation mode: –...
Page 35
The runners have to be adapted as shown above. Screw the runners to the cabinet with the "19 mm" marking facing upwards as shown above. The runners are secured to the spacer blocks. Screw the spacer block to the cabinet with the lower edge flush with the bottom of the cabinet using the 4.0 x 16 mm screws.
Page 36
caps suplied. When installed in a 27 ” (70 cm) wide cabinet the runners are fitted with the cover When installed in a 27 wide cabinet, the runners are fitted with the cover caps supplied. Cut the inserts to the required depth and fit into the sides of the cover caps.
Page 37
1/8" per foot (1cm per meter) to prevent condensation dripping into the appliance. – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used. to reduce the – If the exhaust is ducted into an inac-...
Page 38
Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Ductwork with a diameter of less than 6"...
Page 39
Ensure that power supply is OFF during installation. If you have any questions as to how to connect this hood to your build- ing power supply, please call Miele or consult a licensed electrician. WARNING THIS APPLIANCE MUST BE GROUNDED...
Page 40
Level II ..250 cfm (430 m Level III..350 cfm (600 m Intensive level..400 cfm (680 m Miele Active Charcoal Filter DKF 8, Art.Nr. 28.9961.34...
Page 44
Alteration rights reserved / 44 / 000 US/CDN - 2600 This paper consists of cellulose bleached without the use of chlorine...