NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S 2 MEASUREMENTS AND ADJUSTMENTS 2.1. Adjustment of primary latch switch, secondary latch switch and short switch. 1. Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL.
NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S 3 PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE 3.2.1. Measurement with the outer panel removed. Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted.
NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S 4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOOTING Purpose: Simple way (3/37 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below.
NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S 6.2. PARTS LIST NOTE: 1. When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part. 2. Important safety notice: Components identified by mark have special characteristics important for safety.
NN-SD997S / NN-SD987S / NN-SD967S / NN-SN977S / NN-SN957S / NN-SN947S 6.5. DOOR ASSEMBLY Ref. No. Part No. Part Name & Description Pcs/Set Remarks F30186P40AG DOOR KEY A F301A8P00SAP DOOR A (U) SD997S APH/CPH,SD987S/SB APH F301A8P30SAP DOOR A (U) SD967S APH...