Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 10 646 590...
Contents IMPORTANT SAFETY INSTRUCTIONS .............. 4 Caring for the environment ................ 13 Guide to the appliance .................. 14 Description of functions .................. 16 Operation...................... 17 Turning on the blower.................... 17 Selecting the power level ..................17 Delayed shut-off ....................18 Turning off the blower....................
Page 3
Contents Technical data ..................... 46...
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions. Contact Miele’s Technical Service Department for examination, repair or adjustment.
Page 6
Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults. Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safety of the appliance.
IMPORTANT SAFETY INSTRUCTIONS If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: –...
Page 8
IMPORTANT SAFETY INSTRUCTIONS – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. –...
Page 9
IMPORTANT SAFETY INSTRUCTIONS Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place. Please note that the heat rising from the stovetop during cooking can cause the ventilation hood to become very hot.
Page 10
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Page 11
Wear gloves to protect your hands from being cut. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
Page 12
Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
Guide to the appliance a Exhaust connection for vented mode/recirculation b Controls c Grease filters d Expandable fume deflector e Overhead LED ClearView lighting f OdorFree Charcoal filter Optional accessory for recirculation mode g On / Off button for fan h Buttons for setting the fan power i On / Off button for the Overhead LED ClearView lighting j Drop-down front panel...
Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the (Recirculation mode hoods require a model: Recirculation kit an OdorFree Charcoal Filter (available as optional Vented mode accessories), see "Technical Data" for more information.) Air entering through the intake is cleaned by the grease filters and Air entering through the intake is first...
Operation – the lighting button again. Turning on the blower If automatic switch-off is not activated, Pull out the fume deflector. For the 1 and B displays will flash. optimum extraction with minimum noise levels, always pull out the fume ...
Operation Delayed shut-off It is advisable to run the blower for a few minutes after cooking has finished to neutralize any lingering vapors and odors in the air. Turning off the blower Push in the fume deflector to switch off the blower.
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during vented mode, the hood cannot operate efficiently, causing increased operating noise levels.
Stainless steel surfaces can also be cleaned using a non-abrasive Before cleaning or servicing the stainless steel cleaner, available from hood, disconnect it from the power Miele. supply, see "IMPORTANT SAFETY INSTRUCTIONS". To prevent the surfaces from quickly becoming dirty again, we recommend...
Cleaning and care Grease filter The reusable metal grease filter in the appliance removes solid particles from the kitchen vapors (grease, dust, etc.) preventing soiling of the hood. A dirty filter is a fire hazard! When removing the grease filter, do Cleaning intervals not tilt it downwards at an angle.
Page 22
Select a program with a wash Place the grease filter in the front of temperature between 120°F (50°C) and 150°F (65°C). In a Miele the fume deflector, press it upwards dishwasher use the "Normal" and push it in together with the fume program.
Disposing of the OdorFree Charcoal Charcoal filters are available to order via Filter the Miele web store (see the back of Used OdorFree Charcoal Filters can this manual for details) or from your be disposed of with normal Miele dealer.
The bulbs should be replaced with the following: Bulb type ......LED, GU10 Power ..........3W Replacement bulbs are available from Miele. Pull out the fume deflector, and remove the grease filter as described above. Turn off the blower and the lighting.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section.
Page 27
Installation a 2 brackets for securing the hood in the wall unit. 8 screws ³/₁₆" x ⁹/₁₆" (4 x 15 mm) b 1 spacer strip for securing the hood in the wall unit. for concealing the gap between the rear of the appliance and the wall. c Recirculation kit for recirculation 8 screws M4 x ¹/₂"...
Installation Appliance dimensions DA 3466 a Vented mode; consider accessories when measuring cabinet height and cut- outs (e.g. muffler). b Recirculation mode with conversion kit DUU 151. c For Canada: When installing the ventilation hood with a DAR 3000 drop-down frame, make sure that you note the different wall unit height (please refer to the...
Page 29
Installation DA 3486 a Vented mode; consider accessories when measuring cabinet height and cut- outs (e.g. muffler). b Recirculation mode with conversion kit DUU 151. c For Canada: When installing the ventilation hood with a DAR 3000 drop-down frame, make sure that you note the different wall unit height (please refer to the dimensions given in the DAR 3000 Installation diagram).
Page 30
Installation DA 3496 a Vented mode; consider accessories when measuring cabinet height and cut- outs (e.g. muffler). b Recirculation mode with conversion kit DUU 151. c For Canada: When installing the ventilation hood with a DAR 3000 drop-down frame, make sure that you note the different wall unit height (please refer to the dimensions given in the DAR 3000 Installation diagram).
Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
Installation Installation recommendations – To achieve optimum vapor extraction, the hood must be centered over the cooktop, not to the side. – The cooktop should be no wider than the hood. Preferably, it should be narrower for better extraction. – The mounting area must be easily accessible.
Page 33
Installation a Example: Installation without a front panel installed and with the front edge of the fume deflector flush with the front edge of the cabinetry. b Example: Installation with a front panel to match the cabinetry This installation requires dimension b for the front panel plus ³/₁₆"...
Page 34
Installation Secure the spacer strip underneath the sides of the cabinetry, flush with the rear wall. The brackets are designed for ⁵/₈" and ³/₄" (16 and 19 mm) thick unit sides. Orientate the bracket so that the vertical depth matches the thickness of the unit side.
Page 35
Installation To avoid scratching the fume deflector, do not remove the protective film between the fume deflector and the casing until the hood has been placed in the cabinetry Installation of the hood is carried out without the grease filter placed in position.
Page 36
Installation Secure the hood to the brackets from below using two screws on each Attach the retaining bracket to the side. rear panel. The casing needs a stable attachment to the rear panel. If this is not guaranteed, the casing can incline forward and damage the fume deflector when it is being pulled out and pushed in.
Installation Attaching the front panel The front of the fume deflector can be fitted with a front panel to match existing cabinetry. The front panel must not exceed approx. 2.8 lbs. (1300 g). This applies to front panels with a depth of up to approx.
Installation Aligning the fume deflector Installing the grease filter The position of the fume deflector can be brought forward by up to approx. 1 ³/₈" (35 mm) using the adjusting screws on either side of the fume deflector. This allows the fume deflector to be aligned to the front of the cabinetry on either side.
Installation Exhaust air connection Place the exhaust ducting on the exhaust collar for the hood. Insert the non-return flap, if required. See "Connection for air extraction" Make sure that it opens easily and for further instructions on fitting the closes again by itself.
The DUU 151 conversion kit, available from Miele, is required for operating the hood in recirculation mode. You will also need a charcoal filter (see "Technical data").
Installation Power supply Refer to the notes in "Electrical connection" and "IMPORTANT SAFETY INSTRUCTIONS" before connecting to the electricity supply. Connect the hood to the electrical supply.
CSA C22.1-12, please consult a licensed electrician Canadian Electrical Code, Part I. or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
Air venting – Make sure that all connections are WARNING: Danger of toxic fumes. secure and airtight. Gas cooking appliances release carbon monoxide that can be Remember that any constriction of harmful or fatal if inhaled. the airflow will reduce extraction To reduce the risk of fire and to performance and increase operating properly exhaust air, the exhaust...
Air venting Condensate trap Reducing Collar (optional accessory) If you would like to reduce the In addition to insulating the exhaust environmental impact of your ventilation duct, we recommend installing a system by limiting the CFM output the condensate trap to collect and Reducing Collar can be installed.
Miele This service is available in USA only. dealer or Miele Technical Service. The telephone number for Miele is listed MieleCare, our Extended Service at the back of these instructions. Contract program, gives you the...
Voltage, Frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 2.5 ft (0.75 m) Weight DA 3466 27.6 lbs (12.5 kg) DA 3486 29.8 lbs (13.5 kg) DA 3496 32 lbs (14.5 kg) Optional accessories for recirculation mode: Recirculation kit DUU 151 and charcoal filter DKF 13-1...
Page 47
Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive Phone: 800-843-7231 Vaughan, ON L4K 4V8 609-419-4298 Fax: www.miele.ca www.mieleusa.com...
Page 48
DA 3466 DA 3486 DA 3496 en-US M.-Nr. 10 646 590 / 00...