General information about «HoneyWell N1000» integration module Purpose of document HoneyWell N-1000 integration module. Configuration and operation guide is a reference and information manual. It is meant for configuration specialists and operators of HoneyWell N-1000 module. This module is a part of access control...
63 time zones 8 programmable card formans Protection 1 controller. Setting up HoneyWell N-1000 integration module HoneyWell N-1000 integration module set up procedure Setting up HoneyWell N-1000 integration module is performed in the following succession: Setting up connection of HoneyWell N-1000 ACS...
Apply 3 ( ). Setting up connection of HoneyWell N-1000 ACS Intellect Server is completed. Setting up HoneyWell N-1000 controllers Setting up controllers of HoneyWell N-1000 ACS is carried out on the setting panel of N1000 panel object. This object is...
Page 6
Setting up controller of HoneyWell N-1000 ACS is carried out the following way: Go to setting panel of N1000 panel object. Set connection parameters of controller: Set controller address in Panel address 1 ( ). From Panel type dropdown list select type of connected controller ( ).
Page 7
If it’s necessary to control double-pass set the corresponding checkbox ( ). Ignore violations checkbox if there is no need to store user violations ( ). Free exit checkbox if it’s necessary to ask access while passing to exit ( ). Permanent code-reading checkbox if it’s necessary to read card code permanently and regardless of exit impulse duration ( ).
Setting up access point parameters. Setting up access point readers. Setting up HoneyWell N-1000 access point parameters Setting up access point parameters is carried out on setting panel of N1000 door object. This object is created on the...
Apply in order to save changes ( ). Setting up access point parameters is completed. Setting up HoneyWell N-1000 access point readers Setting up access point readers is carried out on setting panel of N1000 reader object. This object is created on the basis...
Apply in order to save changes ( ). Setting up access point reader is completed. Setting up HoneyWell N-1000 relays Setting up HoneyWell exits Creation and setting up of exits Setting up exits is carried out on setting panel of N1000 exit object.
Setting up exits is carried out the following way: Go to setting panel of N1000 exit object. Set address of exit in Exit address 1 ( ). Impulse setting group set parameters of exit impulse: Duration field set the period during which power supply (impulse) will be given to exit ( ); From the corresponding dropdown list select time zone during which power supply will be given to exit automatically ( ).
Click Apply in order to save changes ( ). Setting up exit groups is completed. Setting up HoneyWell N-1000 entrances Creation and setting up of entrances Setting up entrances is carried out on setting panel of N1000 entrance object. This object is created on the basis of...
Set entrance address in Address 1 ( ). From Entrance dropdown list select type of entrance ( ). Bypass setting group set parameters of entrances disconnection: Duration field set period during which entrance will be disconnected ( ); From corresponding dropdown list select time zone during which entrance disconnects automatically ( ). Set delay of bounce of entrance contacts (in seconds) in the corresponding field ( ).
Apply in order to save changes ( ). Setting up of entrances groups is completed. Setting up HoneyWell N-1000 relay interlock Setting up relay or relay groups interlocks is carried out on setting panel of N1000 interaction object. This object is...
Click Apply in order to save changes ( ). Setting up interlock is completed. Sending commands to HoneyWell N-1000 controller Sending commands to controller is carried out from setting panel of N1000 command object. This object is created on the...
Set command in the line ( ). Note. Description of commands is given in official reference documentation for HoneyWell N1000 system. Click Send command 2 ( ). Sending command to controller is completed. Configuration registration Registration of maximal configuration Registration of maximal configuration is carried out on setting panel of...
Open passage through access point for some time Close the door Close passage through access point Open the door Open passage through access point Controlling HoneyWell N-1000 entrances or entrance group Controlling entrances or entrance group of HoneyWell N-1000 ACS is carried out in...
Repair TZ control Repair controlling entrance (entrance group) using TZ Bypass for time Enable bypass of entrance (entrance group) for some time Controlling HoneyWell N-1000 exits or exit group Controlling exits or exit group of HoneyWell N-1000 ACS is carried out in...
Page 19
Repair TZ control Repair controlling exit (exit group) using TZ Send impulse Send impulse to exit (all exits of the group)