This document is composed by 2 section:
Section
Name
1
Instruction
2
Updating
ABB SACE
DOCUMENTATION CONTENTS
Description
Main features and functions of PR010/T unit
Additional information and/or correction of Instruction
inserted subsequently
ABB
SACE PR010/T
RH0025002

Advertisement

Table of Contents
loading

Summary of Contents for ABB SACE PR010/T

  • Page 1 DOCUMENTATION CONTENTS This document is composed by 2 section: Section Name Description Instruction Main features and functions of PR010/T unit Additional information and/or correction of Instruction Updating inserted subsequently ABB SACE SACE PR010/T RH0025002...
  • Page 2 SACE PR010/T test unit instructions ABB SACE SACE PR010/T RH0025002 L2551...
  • Page 3: Table Of Contents

    Protection unit ....... 14 ABB SACE SACE PR010/T RH0025001 L2551...
  • Page 4 Notes ........20 ABB SACE SACE PR010/T RH0025001...
  • Page 5: Safety Notes

    The manufacturer declines all liability for damage to the unit caused by incorrect or improper usage. ABB SACE also declines all liability for any ensuing damage or injury. Do not use the unit in damp or wet environments. If in doubt about the safety of the unit, take it out of service to prevent inadvertent usage.
  • Page 6: Definitions, Abbreviations

    By connecting to a PC (using the disc supplied by ABB SACE, or SW downloaded from the ABB Internet site) it is possible to upgrade the software of the SACE PR010/T unit. The unit can also save important test results, which may then be downloaded to a PC following a request for a test report.
  • Page 7: Putting Into Service

    3.2 Putting into service To put the SACE PR010/T unit into service, proceed as follows: • Fit the batteries in the corresponding battery compartment (13), taking care to check the polarity first. • Connect the external power supply to the 12 Vdc outlet (11).
  • Page 8: Functions

    4. Functions 4.1 Test Functions The SACE PR010/T test unit tests protection units by monitoring both their HW and SW components. In particular, the unit performs the following tests: • Trip test: by means of SACE TT1 unit • Protection functions test •...
  • Page 9: Communication Functions Test

    ESC key to cancel the last entry/action. 4.3 Parameter reading function If the SACE PR010/T test unit is connected to releases with internal bus, it is possible to read the main parameters of the protection units.
  • Page 10: Protection Unit Interface

    4.6 Test report The SACE PR010/T test unit can save the main test results in order to compile a test report. The unit can store up to five test reports. After the test reports have been downloaded in the PC it is advisable to delete them from the PR010/T so as to have enough free memory available for new reports.
  • Page 11 Test report example: TEST REPORT WITH SACE PR010/T SW Version: 3.2 ******************************** Date: 03/05/00 Hour: 13:55 Operator: Belometti Relay S.Nr.: M0047C03B Relay type: PR112 Relay version: LSIG CB type: E1B800 CT rated current: 250 A Neutral: ******************************** Protection: Threshold [In]: 0.400...
  • Page 12: Special Functions

    5. Software 5.1 Description When the SACE PR010/T test unit is first switched on, it runs an initialisation test. If the test result is successful, the software version and battery charge status are displayed on the screen. To open one of the sub-menus from the main menu, position the cursor using the...
  • Page 13: Report Downloading

    Sub-menus 2. "Report download", 3. "PR010/T Config." and 4. "SW updating" are the same for all the protection units. 5.1.1 Report downloading The SACE PR010/T test unit can download a test report onto a PC which contains all the information indicated under the heading "Test report". 5.1.2 Test unit configuration The test unit configuration can be customized.
  • Page 14: Sw Updating Procedure

    5.2.1 SW updating procedure 1. Switch on the SACE PR010/T test unit. 2. Connect the SACE PR010/T test unit (connector 3) to one of the PC's serial ports (COM1... COM4) using the cable supplied. 3. Run the "SD-TU Interface.exe" program.
  • Page 15: Test Report Downloading Procedure

    The maximum transmission duration is about one minute. 8. If the file is not successfully downloaded, the SACE PR010/T unit will display the message: 9. ’END report download’ 10. ’Press ESC to restart’...
  • Page 16: Test Report Erasing

    If no key is pressed for at least 5 minutes the display switches off automatically to minimise electrical consumption. 6.2 Power supply The SACE PR010/T test unit is a portable instrument operated by 6 rechargeable batteries and/or an external power supply. When installing the rechargeable batteries in the PR010/T unit, pay attention to the polarity indications in the space provided for the batteries.
  • Page 17: Inputs/Outputs

    The test unit may also be connected to the external power supply. 6.3 Inputs/Outputs The SACE PR010/T test unit uses a set of signals to perform its various testing, programming and reading functions. The main characteristics of these signals are as follows: Output voltage range: - 5 …...
  • Page 18: Mechanical Specifications

    Maximum relative humidity: 90%, (non-condensing) MTBF: 15 years @ 30°C 6.5 Standard equipment The SACE PR010/T test unit is supplied in a special case, complete with the following accessories: 1. SACE PR010/T test unit complete with rechargeable batteries 2. SACE TT1 TRIP TEST unit 3.
  • Page 19: Applicable Standards

    6.6 Applicable standards The SACE PR010/T test unit bears the CE quality mark and fully complies with all major international standards on electromagnetic compatibility (EMC). Emissions: IEN55022 class B Electrostatic discharge: IEC/EN 61000-4-2 Radiated immunity: IEC/EN 61000-4-3 Conducted immunity: IEC/EN 61000-4-6 (1kV) 6.7 Error messages and troubleshooting table...
  • Page 20 "Press ESC to return" signal is outside the established range. Check the connection between the SACE PR010/T test unit and device under test. The following error messages are displayed on the SACE PR010/T unit: Troubleshooting guide Faults Causes and errors...
  • Page 21 The PR111 adapter is Replace with the spare one damaged supplied A cable for the Isomax Use the correct cable for the series is connected to an circuit breaker Emax circuit breaker, or vice versa ABB SACE SACE PR010/T RH0025002 L2551 19/20...
  • Page 22: Notes

    In view of ongoing revisions to Standards and the latest developments in technology and materials, the characteristics (mechanical, electrical and electronic) and overall dimensions indicated in this handbook are only deemed legally binding subject to confirmation by ABB SACE. The test unit does not need recalibrating.
  • Page 23 COMPATIBILITY BETWEEN WINDOWS OPERATING SYSTEMS AND SD-TEST UNIT INTERFACE Operating Installation Operating Notes System requirements requirements Windows XP Any user Any user or earlier Windows 7 Administrator Any user Use with “non administrator” profile user can be obtained by installing the latest SD- Test Bus Interface version available (from file 1SDC200002X0005 15.zip or more recent) Windows 10...