SYSTEM HARDWARE DESCRIPTION

System 1010BX is housed inside a cylindrical explosion-proof NEMA-7 aluminum, epoxy painted
case. The main metering compartment front and rear sections are sealed with an O-Ring with
separate threaded covers. The front section houses the main electronics and the optional
Magnetic Touch-Panel User Interface with a 2x16 character LCD Alphanumeric Display view-
able through a tempered glass window. The rear section contains terminal blocks for the fused
power input and data I/O wiring. The primary instrumentation output is an isolated 4-20 mA
current loop. The meter includes a conventional RS-232 I/O port.
The main metering compartment is connected to the secondary housing by an aluminum pipe
that provides a pass-through for flow transducer and temperature sensor cabling. The second-
ary housing provides screw-on wire clamp terminals for flow and temperature sensors. To
maintain the NEMA-7 explosion-proof rating, all cabling and the transducer physical and elec-
trical design must be in compliance with hazardous area specifications.

SPECIFICATIONS

Temperature:
Operational and Storage
Power Consumption
G-Force Rating
For Hazardous Area Use
Provisions for User Menu Access
Options
1.4

STANDARD FEATURES

Same features as the 1010 family of NEMA 4X flow computers except constructed in a
compact NEMA-7 explosion-proof housing.
Flexible Setup options using either Magnetic Wand or a PC connected to RS-232 port.
Integral 2x16 Character LCD panel display shows real-time data and Installation Menu
for Magnetic Wand programming.
Flexible mounting - either on pipe or located up to 300 feet (100m) from the transducers.
For distances greater then 300 feet, please contact Controlotron Customer Service.
Operating Temperature
Electronics: 14ºF to 122ºF (-10ºC to 50ºC)
LCD display: 14ºF to 122ºF (-10ºC to 50ºC)
Storage Temperature
Electronics: -4ºF to 140ºF (-20ºC to 60ºC)
*Transducers temperature ratings depend on the individual
transducer type(s).
110/220 VAC, less than 10 watts.
Instrument survives 3' drop onto 1" plywood (standard indus-
trial drop test). Mechanical design supports operation in a high
vibration environment.
Explosion-proof case designed for installation in Division 1/Zone
1 hazardous environments when installed per our instructions.
Agency approvals: CE (for EM) and FM/CENELEC pending. In-
ternational approvals pending.
Magnetic triggers (4-Arrows + Enter).
RS-232 interface for menu access and Datalogger dump.
Stainless Steel Case
Dial-up Modem
One RTD temperature sensing channel (measures clamp-on
liquid temperature
Blind System (programming vial serial link only)