ELECTRICAL CIRCUIT
Power
See Diagram
Blk
Blu
Compressor
Pink
Temp Warning
Cold
Red
Alarm
Control
Buzzer
Off
On
Red
Door
Switch
Power On
EC40
SYSTEM SCHEMATIC
Condenser
High Side
Process Tube
Drier
Capillary
Low Side Process Tube
SS1
IMPORTANT
If any green grounding
wires are removed dur-
Wh
ing
servicing,
must be returned to
their original position
and properly secured.
WIRING DIAGRAM
Run
Capacitor
Interior
Light
Compressor
Controller
Evaporator
Compressor
Suction
Tube
Discharge
IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
they
should not attempt to make
repairs due to the possibility of
electrical
shock.
power cord before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three inches
of clearance must be provided on all sides of the freezer for air circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
Blu
Wh
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
C26
TEMPERATURE CONTROL
8.5°F cut in, -3.5°F cut-out @ number 1 setting.
PERFORMANCE (Control at number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
216803200
SERVICE DATA SHEET
MANUAL DEFROST
UPRIGHT FREEZER
Disconnect
70°F
2 to 8°F
30-40%
of cycle)
105-120
1
3
14-0
of cycle), PSIG
110-125
1
3
90°F
2 to 8°F
45-60%
110-125
14-0
155-170
PD644

Advertisement

loading

Summary of Contents for Frigidaire FFU17C3AW1

  • Page 1 This product is designed for “free standing installation only” and three inches of clearance must be provided on all sides of the freezer for air circulation. The freezer should be positioned on a solid floor, and the front of the...
  • Page 2 CIRCUIT ÉLECTRIQUE Courant électrique Voir schéma Blanc Noir Bleu Compresseur Rose Avertissement temp. Commande Rouge Alarme de froid Sonnerie Arrêt Marche Rouge Interrupteur Lampe de porte intérieure Circuit fermé FEC40 SCHÉMA DU SYSTÈME Condenseur Tube de traitement côté haute pression Déshydrateur d'aspiration Capillaire...