Operating and Installation
Instructions
Ventilation Hood
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 039 140

Advertisement

Table of Contents
loading

Summary of Contents for Miele DAS 2620

  • Page 1 Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 039 140...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS ............Caring for the environment ................13 Guide to the ventilation hood ................14 Description of functions ................... 16 Operation......................17 Turning on the fan....................17 Selecting the power level ..................17 Delayed shut-down ..................... 17 Turning off the blower..................
  • Page 3 Contents Technical data ....................34 Optional accessories for recirculation mode............34...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS Safety with children  Children must be kept away from the ventilation hood unless they are constantly supervised.  Children must not be allowed to clean or service the hood.  Please supervise children in the vicinity of the hood and do not let them play with it.
  • Page 6  Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions. Contact Miele’s Technical Service Department for examination, repair or adjustment.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  Do not use a power bar or extension cord to connect the ventilation hood to electricity. These are a fire hazard and do not guarantee the required level of appliance safety.  To ensure safe operation, only use the ventilation hood after it has been properly installed.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS Correct use  WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: - a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. - b) Always turn the hood on when cooking at a high heat.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS – 4) You can fight the fire with your back to an exit. *Based on “Kitchen Fire Safety Tips” published by NFPA.  The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop. - When using the ventilation hood over a gas cooktop, ensure that any burners in use are always covered by cookware.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 11  When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Always observe local building code requirements when selecting duct material.  Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
  • Page 12 IMPORTANT SAFETY INSTRUCTIONS Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer.
  • Page 13: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 14: Guide To The Ventilation Hood

    Guide to the ventilation hood...
  • Page 15 Guide to the ventilation hood a Vent collar b Controls c Charcoal filters Optional accessories for recirculation mode d Grease filter e Pull-out canopy f Overhead lighting g Control for switching the blower on and off h Controls for setting the blower power i Button for switching the lighting on and off j Drop-down front panel The front panel of the pull-out canopy can be fitted with one that matches your...
  • Page 16: Description Of Functions

    Description of functions The following functions are available on your ventilation hood, depending on the model: Extraction mode Air entering through the intake is cleaned by the grease filters and conducted out of the building. Recirculation mode (only with conversion kit and charcoal filters as optional accessories, see “Technical data”) The air is drawn in and cleaned first by...
  • Page 17: Operation

    Operation It also reduces the risk of residues Turning on the fan accumulating in the ventilation hood Switch the fan on as soon as you start and any resulting odors. cooking. This is to ensure that vapors are captured right from the start. Turning off the blower ...
  • Page 18: Power Management

    Operation  Press the  button to turn power Power management management off. The ventilation hood is equipped with a The 1 and B indicators will flash. power management system. Power management helps to save energy. It  To turn it on, press the  button. ensures that the blower power level is The 1 and B indicators will be reduced automatically and that the...
  • Page 19: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 20: Cleaning And Care

    Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
  • Page 21: Grease Filter

    Cleaning and care  Pull out the canopy. Grease filter  Risk of fire An oversaturated grease filter is a fire hazard. Clean the grease filter at regular intervals. The re-usable metal grease filter in the appliance removes solid particles from the kitchen vapors (grease, dust, etc.), preventing soiling of the ventilation hood.
  • Page 22: Replacing The Grease Filter

    Ensure the spray arm is not obstructed.  Use a commonly available household dishwashing detergent.  In a Miele dishwasher use the “Normal” program. Depending on the detergent used, cleaning the filter in a dishwasher may cause the inside filter surfaces to ...
  • Page 23: Odorfree Charcoal Filter

    Replace the charcoal filters when they Charcoal filters are available to order via no longer absorb kitchen odors the Miele website or from your Miele effectively, and at least every 6 months. dealer. Disposing of charcoal filters The charcoal filters are listed under ...
  • Page 24: Installation

    *INSTALLATION* Installation Before installation Installation materials  Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT 1 non-return flap SAFETY INSTRUCTIONS” chapter. for fitting into the exhaust socket on the Information is subject to change. Please motor unit (not needed for recirculation refer to our website to obtain the most mode).
  • Page 25: Installation Materials For Recirculation Mode

    *INSTALLATION* Installation 4 M4 x 8 mm screws DML 2000 installation kit for installing a hinged front panel to match kitchen cabinetry (not supplied; available as an optional accessory) 5 (9)* screws, 4 x 15 mm Installation materials for recirculation mode You need the following optional accessories for recirculation mode. 4 screws, 4 x 30 mm 8 (12)* screws, 4 x 15 mm DKFS 31-x installation kit...
  • Page 26: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions Diagram 1: DAS 2620 in a 23 ⁵/₈" (600 mm) wide cabinet. The drawing is not to scale...
  • Page 27 *INSTALLATION* Installation Diagram 2: DAS 2920 in a 35 ⁷/₁₆" (900 mm) wide cabinet The drawing is not to scale See diagram 1 for side view.
  • Page 28 *INSTALLATION* Installation Diagram 3: DAS 2920 in a 23 ⁵/₈" (600 mm) wide cabinet or in a 35 ⁷/₁₆" (900 mm) wide cabinet with side compartments The drawing is not to scale See diagram 1 for side view. Footnotes for diagrams 1 to 3: a Vented or recirculation with DUU 150 conversion kit b DML 2000 bracket (accessory) for installing a front panel * In this installation situation, the deflector plate is flush with the front edge of the...
  • Page 29: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 30: Air Venting

    “Appliance dimensions”). This applies If the exhaust is ducted through an in particular when using flat ducting. outside wall, a Miele wall vent or roof vent (available as an optional - The ducting should be as short and accessory) is recommended. Both of straight as possible.
  • Page 31: Condensate

    *INSTALLATION* Installation Condensate Miele will not accept warranty claims for any functional defects or damage If the ducting is to run through cool caused by inadequate ducting. rooms or ceiling space, for example, the significant variations in temperature Reducing Collar between the different areas can cause condensate to form.
  • Page 32: Electrical Connection

    CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 33: Customer Service

    In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 34 Technical data Fan motor 350 W Overhead lighting 3 W Total connected load 353 W Supply voltage, frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 2.5 ft (0.75 m) Weight DAS 2620 33.1 lbs (15 kg) DAS 2920 37.5 lbs (17 kg) Optional accessories for recirculation mode You need the following installation kits for recirculation mode: - DUU 150 or DUU 151 - DKFS 31-900 P or DKFS 31-R (reactivatable).
  • Page 35 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...