Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions
for the disassembly of HPE products to remove components and materials requiring selective treatment, as defined by
Directive 2012/19/EU of the European Parliament and of the Council on Waste Electrical and Electronic Equipment
(WEEE).
1.0 Items Requiring Selective Treatment
1.1 Items listed below are classified as requiring selective treatment.
1.2 Enter the quantity of items contained within the product which require selective treatment in the right column, as
applicable.
Item Description
Printed Circuit Boards (PCB) or Printed Circuit
Assemblies (PCA)
Batteries
Mercury-containing components
Liquid Crystal Displays (LCD) with a surface
greater than 100 sq cm
Cathode Ray Tubes (CRT)
Capacitors / condensers (Containing PCB/PCT)
Electrolytic Capacitors / Condensers measuring
greater than 2.5 cm in diameter or height
External electrical cables and cords
Gas Discharge Lamps
Plastics containing Brominated Flame Retardants
weighing > 25 grams (not including PCBs or PCAs
already listed as a separate item above)
Components and parts containing toner and ink,
including liquids, semi-liquids (gel/paste) and toner
Components and waste containing asbestos
MF877-00
Template Revision C, 30-July-2018
Copyright 2018 Hewlett Packard Enterprise Development LP
HPE instructions for this template are available at
Notes
With a surface greater than 10 sq cm
All types including standard alkaline and lithium
coin or button style batteries
For example, mercury in lamps, display backlights,
scanner lamps, switches, batteries
Includes background illuminated displays with gas
discharge lamps
Include the cartridges, print heads, tubes, vent
chambers, and service stations.
MF877-01
Quantity
of items
included
in product
8
2
0
0
0
0
14
0
0
0
0
0
Page 1

Advertisement

loading

Summary of Contents for HP ProLiant DL380 Gen10 Plus

  • Page 1 Marketing Name / Model [List multiple models if applicable.] HPE ProLiant DL380 Gen10 Plus Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions for the disassembly of HPE products to remove components and materials requiring selective treatment, as defined by Directive 2012/19/EU of the European Parliament and of the Council on Waste Electrical and Electronic Equipment (WEEE).
  • Page 2 Quantity of items Item Description Notes included in product Components, parts and materials containing refractory ceramic fibers Components, parts and materials containing radioactive substances 2.0 Tools Required List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed.
  • Page 3 1. Remove top cover of systems by hood latch. 2. Remove Fan cage module, Air baffle and Riser cage from system. 1. Remove top cover of systems. MF877-00 Page 3 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 4 3. Remove lithium battery from the system by medium flat head screw driver. 4. Remove Mega-cell HSTNS-BB05 from the system MF877-00 Page 4 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 5 5_a. Use Torx driver with T15 to unlock screws 5_b. Remove bracket with PCA from LFF system \ Remove HDD cage with PCA from SFF system. 6. Remove the power supply(s) from system. MF877-00 Page 5 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 6 7_a. Use Torx driver with T15 to unlock thumbscrew. 7_b. Remove the system board with tray from system. MF877-00 Page 6 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 7 8_a. Use Torx driver with T15 to unlock screws. 8_b. Remove the riser card (PCA) 2. Remove Fan cage module and Riser cage from system. MF877-00 Page 7 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 8 9_a. Use Torx driver with T15 to unlock screws. 9_b. Remove HDD BP (PCA) from bracket [LFF system] \ Remove HDD BP (PCA) from HDD cage [SFF system]. MF877-00 Page 8 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 9 10_a. Use Torx driver with T15, 5 mm socket screwdriver and 8 mm socket screwdriver to unlock screws. 10_b. Remove System board (PCA) from tray. MF877-00 Page 9 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 10 10_a. Use Torx driver with T15, 5 mm socket screwdriver and 8 mm socket screwdriver to unlock screws. 10_b. Remove System board (PCA) from tray. Remove Electrolytic Capacitors (C801: 25mm*55mm and C237, C238, C241:10mm*25mm) from power supply HSTNS-PD40, HSTNS-PD40-1. MF877-00 Page 10 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP...
  • Page 11 Remove Electrolytic Capacitor(C102: 25mm*25mm) from HSTNS-PL40, HSTNS-PL40-1 Remove Electrolytic Capacitor (BC1: 25mm*60 mm and C106/C107/C108 10mm*25mm) from power supply HSTNS-PC40, HSTNS-PC40-1. MF877-00 Page 11 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 12 Remove Electrolytic Capacitor (C801:25mm*60mm and C237/C238/C241:10mm*25) from power supply HSTNS- PD41, HSTNS-PD41-1. Remove Electrolytic Capacitor (C102: 30mm*30mm) from power supply HSTNS-PL41, HSTNS-PL41-1. MF877-00 Page 12 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 13 Remove Electrolytic Capacitor (BC1: 25mm*60 mm and C106/C107/C108: 10mm*25mm) from power supply HSTNS-PC41, HSTNS-PC41-1. Remove Electrolytic Capacitor (C801: 25mm*60mm and C212/C233/C238: 10mm*25mm) from power supply HSTNS-PD44, HSTNS-PD44-1. MF877-00 Page 13 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 14 Remove Electrolytic Capacitor (C102: 30mm*30mm) from power supply HSTNS-PL45, HSTNS-PL45-1. Remove Electrolytic Capacitor (C101,C105,C106,C114,C115: 8mm*20mm) from power supply HSTNS-PL46-1. MF877-00 Page 14 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 15 Remove Electrolytic Capacitor from power supply HSTNS-PF46-1. Remove Electrolytic Capacitors (C201,202: 10mm*38.5mm, C200: 26mm*43mm , C250,251: 13mm*50mm) from power supply HSTNS-PR62. MF877-00 Page 15 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...
  • Page 16 Remove Electrolytic Capacitor (C102: 30mm*30mm) from power supply HSTNS-PL62. Remove Electrolytic Capacitor (C12:1.60mm*25mm, C328:18mm*30mm) from power supply HSTNS-PD70. MF877-00 Page 16 Template Revision C, 30-July-2018 Copyright 2018 Hewlett Packard Enterprise Development LP HPE instructions for this template are available at MF877-01...