Electromagnetic flowmeter
Introduction
ProcessMaster
Wafer FEM630
This manual describes how to configure an Ethernet
connection for the following electromagnetic
flowmeters:
• ProcessMaster Wafer FEM630
EtherNet/IP, Modbus TCP, Webserver
Valid from firmware version 01.09.00
Measurement made easy
For more information
Additional documentation on ProcessMaster,
HygienicMaster FEX600 series is available for
download free of charge at www.abb.com/flow.
Alternatively, simply scan this code:

Advertisement

Table of Contents
loading

Summary of Contents for ABB ProcessMaster Wafer FEM630

  • Page 1 Wafer FEM630 This manual describes how to configure an Ethernet Additional documentation on ProcessMaster, connection for the following electromagnetic HygienicMaster FEX600 series is available for flowmeters: download free of charge at www.abb.com/flow. • ProcessMaster Wafer FEM630 Alternatively, simply scan this code:...
  • Page 2: Table Of Contents

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A Contents Safety .
  • Page 3: Safety

    ABB Automation Products GmbH and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/...
  • Page 4: Connecting Ethernet To The Flowmeter

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A 4 Connecting Ethernet to the flowmeter Ethernet card –...
  • Page 5: Power Over Ethernet (Poe)

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A Power over Ethernet (PoE) The PoE card supplies power through the Ethernet...
  • Page 6: Preparing The Ethernet Cat5E Cable

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …Connecting Ethernet to the flowmeter Preparing the EtherNet Cat5e cable M12 plug (option)
  • Page 7: Rj45 Connector (Option)

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A RJ45 connector (option) WARNING Various Options for RJ45 connection are available from the...
  • Page 8: Wiring With Different Network Topologies

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …Connecting Ethernet to the flowmeter Wiring with different network topologies A –...
  • Page 9: Parameterization For Start-Up

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A Parameterization for start-up On initial start, do the steps that follow: 1 Make sure that the transmitter is connected to the Ethernet.
  • Page 10: Ethernet Card Status Leds

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …Installation Ethernet card status LEDs The 6 LEDs on the Ethernet card indicate the status of each port and the network.
  • Page 11: Webserver For Device Configuration

    5 Webserver for device 6 Web page access configuration Password The default password is password. The system will prompt you The built-in webserver allows for device configuration using a web browser. You must log in to access the device. The device to set a new password.
  • Page 12: Webpage Certificates

    The device generates a default certificate. The certificate has A more complex PKI structure is supported, with intermediate the properties that follow: certificates. • Issuer: ABB Device Root CA -----BEGIN CERTIFICATE----- • Subject: my-hostname.my-domain <Endpoint certificate for server> • Serial: Randomly generated •...
  • Page 13: Device To Network

    Device to network 8 EtherNet/IP Device profile You can configure the IP address and the hostname of the device. The device supports the DHCP function. The device corresponds to the profile 0x43, Generic Device, The device is shipped with DHCP enabled. (keyable).
  • Page 14: Menu Structure In Hmi

    If it's part of the subnet, the first block of numbers should be identical to HOST IP - for example, 192.168.1.10 NTPServer1 IP address factory default: 000.000.000.000 NTPServer2 IP address factory default: 000.000.000.000 Host name factory default: ABB-Flow Domain name factory default: my-domain DNS1 IP address automatically set with DHCP = ON: 000.000.000.000 DNS2 IP address Webserver Access "disabled, Read only,...
  • Page 15 Menu Settings Description ModbusTCP Access disabled, Read only, Full Factory Default is disabled IEEE Format enabled, disabled factory default: Enabled Data link layer Chassis MAC Example: 00-24-59-11-00-69 address P1 MAC address P2 MAC address P1 auto negotiation enabled, disabled enabled P1 speed set P1 duplex set P1 speed status...
  • Page 16: Set The Ip-Address And Local Host Name

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A 10 Set the IP-Address and Local Host name Addressing via Rockwell's BOOTP/DHCP Server The device must be given an IP address before communication...
  • Page 17: Ethernet/Ip Interface

    11 EtherNet/IP interface The Assemblies (100-107 and 110) can be implicitly transferred. 104 (Extended_Device_Status) A summary of these assemblies is shown below. Device_Status Mass_flowrate_exceeds_limits_0_0 100 (Flow) 101 (Totalizer) 102 (Diag 103 (All Process Values) Inputs) Volume_flowrate_exceeds_limits_0_1 Volume_Flow Totalizer_Qv_ Conductivity Volume_Flow Simulation_is_on_0_2 Flowrate_to_zero_0_3 Mass_Flow...
  • Page 18 P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …EtherNet/IP interface 110 (Output) 102 (Diag Values)
  • Page 19 104 (Extended Device Status) Data Type Display Bytes Access 104 (Extended Device Status) Data Type Display Bytes Access Device_Status BYTE Read Only Electrode short circuit BOOL Decimal Read Only detection_4_0 Mass_flowrate_exceeds_ BOOL Decimal Read Only limits_0_0 Electrode open circuit BOOL Decimal Read Only detection_4_1...
  • Page 20 P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …EtherNet/IP interface EtherNet/IP Alarms FEP63x / FEH63x / FEW53x Error messages of the FEP63x / FEH63x / FEW53x are displayed...
  • Page 21 Table 11 Ethernet/IP Alarms FEP63x / FEH63x / FEW53x 104 (Extended_Device_Status) Data Type Display Bytes Access Device_Status BYTE Read Only Mass_flowrate_exceeds_limits_0_0 BOOL Decimal Read Only Volume_flowrate_exceeds_limits_0_1 BOOL Decimal Read Only Simulation_is_on_0_2 BOOL Decimal Read Only Flowrate_to_zero_0_3 BOOL Decimal Read Only Maintenance_interval_is_reached_0_4 BOOL Decimal...
  • Page 22: Ethernet/Ip Interface Details

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A 12 EtherNet/IP interface details Service Code Service Name...
  • Page 23 [Message Router] 0x02 [Assembly] 0x04 The Assembly Object binds attributes of multiple objects, that Service Code Service Name data can be sent or received from any object over a single 0x0E connection. Assembly objects can be used to bind input or 0x01 output data.
  • Page 24 P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …EtherNet/IP interface details [Connection Manager] 0x06 [File] 0x37...
  • Page 25 [DLR] 0x47 [QoS] 0x48 The Device Level Ring (DLR) object provides the configuration Quality of Service (QoS) is a common term for mechanisms for and status information interface for the DLR protocol. The DLR handling data streams with different priorities or other delivery protocol is a Layer 2 protocol that enables the use of an characteristics.
  • Page 26 P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …EtherNet/IP interface details [Port] 0x55 [TCP/IP Interface] 0xF5...
  • Page 27 [Ethernet Link] 0xF6 Service Code Service Name 0x0E The Ethernet Link Object manages connection-specific 0x01 counters and status information for an IEEE 802.3 0x10 communication interface. Each device supports exactly one instance of the Ethernet Link Object for each IEEE 802.3 0x02 communication interface in the module.
  • Page 28 P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A …EtherNet/IP interface details Attr ID Name...
  • Page 29: Ethernet/Ip Unit Overview

    13 EtherNet/IP unit overview Group name Code Ethernet/IP The following units are available in the device. The unit codes imperial gallons per day igal/d 1440 correspond to the Common Industrial Protocol (CIP™) Vol 1, Ed oil barrels per second bbl/s 143F 3.25 Appendix D.
  • Page 30: Ethernet Card Firmware Update

    P R O C E S S M A S T E R W A F E R F E M 6 3 0 | C O M / F E M 6 3 0 / E / M B - E N R E V . A 14 Ethernet card firmware update To update the Ethernet card firmware, log on to the flowmeter’s webserver.
  • Page 31: Cyber Security

    Cyber Security Version and checksum for the current Ethernet card firmware Device firmware is not available for download from the ABB library. Please refer to your local ABB Service Organization if a firmware update is required.
  • Page 32 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.