hit counter script
Download Print this page
Electrolux E32AF75JPS Service Data Sheet
Electrolux E32AF75JPS Service Data Sheet

Electrolux E32AF75JPS Service Data Sheet

Standard - automatic defrost freezer models (r134a)
Hide thumbs Also See for E32AF75JPS:

Advertisement

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
Capacitor Run or
70°F (21°C) Ambient
Induction Run
Operating Time
40 to 50%
-3° to 3° F
Freezer Temperature
-19° to -16° C
Low Side Pressure
6 to 12 psig
(cut-in)
41 to 83 kPa
Low Side Pressure
-1 to 3 psig
(cut-out)
-4 to 21 kPa
High Side Pressure
85 to 100 psig
(last 1/3 cycle)
575 to 670 kPa
Wattage (last 1/3 cycle)
100 to 120
Amps (running)
.9 to 1.1
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cabinet Size
Cut-in
Cut-out
19'
21° F (-6° C)
42° F (6° C)
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
2.3
1100 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max) 60 Hertz
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Thermostat
Models with orange wire close at 8.96° F (-12.8° C)
Heater Wattage
165
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
1
Green/Yellow
2
Yellow
3
Black
4
Light Blue
IMPORTANT: PLEASE RETURN THIS SHEET TO IT'S
ORIGINAL LOCATION
SERVICE DATA SHEET - 297299800
90°F (32°C) Ambient
STANDARD - AUTOMATIC DEFROST FREEZER
55 to 65%
-3° to 3° F
-19° to -16° C
IMPORTANT SAFETy NOTICE
6 to 12 psig
The information provided herein is designed to assist qualified
41 to 83 kPa
repair personnel only. Untrained persons should not attempt to
-1 to 3 psig
make repairs due to the possibility of electrical shock. Disconnect
-4 to 21 kPa
power cord before servicing.
120 to 135 psig
810 to 910 kPa
IMPORTANT
110 to 130
If any green grounding wires are moved during servicing,
1.0 to 1.2
they must be returned to their original position and properly
secured.
Heater
CAUTION:
Watts
Ohms
shielded from torch flame. Do not allow torch to contact
550
24
insulation; it will char at 200°F.
Amps
NOTE:
Products come equipped with an Electronic Defrost
0.13 Running
Control. To initiate defrost, press and hold air filter and alarm
reset key simultainiously for three seconds. To terminate defrost,
press and hold air filter and alarm reset key simultainiously for
three seconds
Connects to:
Ground
Water Valve
Line
Neutral
MODELS (R134a)
All electrical parts and wiring must be
ICE MAKER INFORMATION
Test Cycling
Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill
The water fill adjustment
Adjustment
screw will change the
fill time. One full turn is
Motor
Gear
equal to 20cc (.68 oz.).
The correct fill is 95 to
105cc (3.2 to 3.6 oz.).
Mounting
Plate
When a water valve is
Screws
replaced, the fill volume
must be checked.
Mounting
Plate
Screw
Timing
Gear
LINE
POWER
ICE MA KER
BRN
B LK
P-3
THER MAL
CUT-OUT
MOTOR
HO LD
SW ITCH
YEL
RED
T HERMOSTAT
BLK
MOLD HEATER
GRN / yEL
P-1
WATER FILL
MOL D
MOUN TING
S WITCH
PLATE
MAKER
ICE
Water Fill Volume
NEUT RAL
P-4
BLU
SHUT-OF F
SWITCH
LT. BLU
P-2

Advertisement

loading

Summary of Contents for Electrolux E32AF75JPS

  • Page 1 SERVICE DATA SHEET - 297299800 PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT ICE MAKER INFORMATION CONTROL SETTING Capacitor Run or 70°F (21°C) Ambient 90°F (32°C) Ambient STANDARD - AUTOMATIC DEFROST FREEZER Test Cycling Induction Run MODELS (R134a) Operating Time 40 to 50% 55 to 65%...

This manual is also suitable for:

Ei32af65js