Quick Links

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
AT MID-POINT CONTROL SETTING
type a with run/start
65°F (18°c) ambient
capacitor
Operating Time
N/A
Temperature
34º F to 45º F
30 to 45 psig
Low Side Pressure (cut-in)
208 to 310 kPa
-2 to 4 psig
Low Side Pressure (cut-out)
-14 to 28 kPa
High Side Pressure
90 to 120 psig
(last 1/3 cycle)
621 to 827 kPa
Wattage (last 1/3 cycle)
85 to 125
Amps (running)
.75 to 1.2
Base Voltage
115 vac (127 vac max)
cOndenser Fan mOtOr
Watts
rpm
3.1
1100 CW Opposite Shaft
evapOratOr Fan mOtOr
1.7 each
9000
service data sheet
reFriGeratOr draWers - r134a
90°F (32°c) ambient
impOrtant saFety nOte
30 to 50%
The information provided herein is designed to assist qualified
34º F to 45º F
repair personnel only. Untrained persons should not attempt to
30 to 45 psig
208 to 310 kPa
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
-2 to 4 psig
-14 to 28 kPa
impOrtant
130 to 175 psig
896 to 1207 kPa
If any green grounding wires are removed during servicing,
85 to 125
they must be returned to their original position and properly
.75 to 1.2
secured.
amps
cautiOn
0.03 Running
all electrical parts and wiring must be shielded from torch
flame. dO nOt allow torch to touch insulation; it will char
.02 each
at 200°F and flash ignite (burn) at 500°F. excessive heat will
distort the plastic liner.
nOte
Your Electrolux refrigerator drawers has been designed for
built-in installation. Your refrigerator drawers do not require
additional air space for top, sides or rear. The front grille must
nOt be obstructed.
To ease unit installation and removal, it is recommended that
the cabinet rough opening dimensions be increased by at least
¼ inch over the dimensions given for your unit.
impOrtant: pLease return this sheet tO
it's OriGinaL LOcatiOn.
241958200
WarninG
double drawer refrigerator drawers are designed to be
built-in only. they can not be used for free-standing.
all screws supplied with the anti-tip Kit are for mounting
the bracket directly to wall studs. these screws will not
work if used with sheetrock (dry wall) or anything other
than wall studs.
unit dimensions
Width
Height
23
13
/
inch
34-35 inches
16
Depth
26
3
/
inch
4

Advertisement

loading

Summary of Contents for Electrolux R134A

  • Page 1 200°F and flash ignite (burn) at 500°F. excessive heat will distort the plastic liner. nOte Your Electrolux refrigerator drawers has been designed for built-in installation. Your refrigerator drawers do not require additional air space for top, sides or rear. The front grille must nOt be obstructed.