PLC-XC56 Expand Serial Command Functional Specifications Overview 1.1 This Functional Specification defines communication functions for PLC-XC56 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the commands are defined as Expand Serial Commands.
PLC-XC56 Expand Serial Command Functional Specifications Notes for communication 1. Expand Serial Command is defined as one command / one line that starts with “C” and ends with carriage return (0x0D) 2. There are two types of commands: Functional Execution Command and Status Read Command.
PLC-XC56 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Item CF_BRIGHT_%1[CR] Set Brightness value CF_CONT_%1[CR] Set Contrast value CF_COLOR_%1[CR] Set Color value CF_TINT_%1[CR] Set Tint value CF_SHARP_%1[CR] Set Sharpness value CF_GAMMA_%1[CR] Set Gamma value CF_WBAL-R_%1[CR] Set White Balance Red value CF_WBAL-G_%1[CR]...
PLC-XC56 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_BRIGHT[CR] Get Brightness value CR_CONT[CR] Get Contrast value CR_COLOR[CR] Get Color value CR_TINT[CR] Get Tint value CR_SHARP[CR] Get Sharpness value CR_GAMMA[CR] Get Gamma value CR_WBAL-R[CR]...
PLC-XC56 Expand Serial Command Functional Specifications CR_HPOS[CR] Get setting status of Horizontal Position 6.6 Lamp Status Read Command Table Status read command Item CR_LAMPREPL[CR] Get the information for Lamp replacement time CR_LAMPH[CR] Get lamp total running time CR_LAMPCORRESPH[CR] Get corresponding lamp use time CR_LAMPMODE[CR] Get Lamp Mode status CR_LAMPSTS[CR]...
PLC-XC56 Expand Serial Command Functional Specifications CR_TEMPFAIL[CR] Get temperature when sensors detect abnormal temperature 7. Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter determination error (digit number error, including invalid value, etc.) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (command for Optional function which is not installed)
PLC-XC56 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format PC issues commands in format as below: Pattern1 : “CF_COMMAND” [CR] Pattern2 : “CF_COMMAND_”%1 [CR] CF_ : Header COMMAND : Character line %1 : Parameter (Character line) _ : Space (To separate COMMAND and Parameter) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-XC56 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1”[CR] "000~063” --------------- Directly select Brightness setting value "UP” ----------------------- Current Brightness setting value + 1 "DN” ----------------------- Current Brightness setting value – 1 Set Brightness value of user control Projector does not save the value set with this command so that it returns its Details original when projector turning into Stanby mode or ALL is OFF.
PLC-XC56 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1”[CR] “000~015” ---------------- Directly select Sharpness setting value “UP” ------------------------ Current Sharpness setting value + 1 “DN” ------------------------ Current Sharpness setting value - 1 Set Sharpness value of user control Projector does not save the value set with this command so that it returns its Details original when projector turning into Stanby mode or ALL is OFF.
PLC-XC56 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1”[CR] “000” ------ Xlow “001” ------ Low “002” ------ Mid “003” ------ High Set Color Temperature. (Available only in the normal Power ON status) The value set by this command will not be saved to the projector. Therefore, when Details turning into Stanby-mode or ALL is OFF, the value returns to original setting.
PLC-XC56 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command “CF_IMAGE_%1”[CR] “DYNAMIC” ------ Dynamic (Fixed value to enable projection with a sharp, powerful picture tone) “STAND” ---------- Standard (Image adjust value is set to factory default) “REAL” ------------ Real (Fixed value to display graphic image with natural tone) “CINEMA”...
PLC-XC56 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1”[CR] “0000~0031” --------------- Directly select Fine Sync setting value “UP” -------------------------- Current Fine Sync setting value + 1 “DN” -------------------------- Current Fine Sync setting value - 1 Set Fine Sync value of PC signal Projector does not save the value set with this command so that it returns its Details...
PLC-XC56 Expand Serial Command Functional Specifications 8.5.4 CF_H – POS Command Command “CF_H-POS_%1”[CR] “0000~nnnn” --- Directly select Horizontal Position setting value “nnnn” shows maximum value, it is current Total Dots value - Display Dots value “UP” -------------- Current Horizontal Position setting value + 1 “DN”...
PLC-XC56 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1”[CR] “0100”~”nnnn” --- Directly select Display Line setting value “nnnn” shows maximum value, it is current Total Line value – Vertical Position value “UP” -------------- Current Display Line setting value + 1 “DN”...
PLC-XC56 Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1 Command Command “CF_INPUT1_%1_”[CR] “ANALOG” ----------Select Analog RGB Input “YPBPR” ------------- Select Component “SCART” ------------- Select SCART Select Computer 1 input and source specified by %1 at the same time. Details This command is available in normal Power ON status. Acceptable “000”[CR] Response...
PLC-XC56 Expand Serial Command Functional Specifications “VIDEO” --------- Select Video Input When %1 is S-VIDEO “S-VIDEO” ------ Select S-Video Input Select Input specified by %1 and also Source specified by %2 at once Details This command is available in normal Power ON status. Acceptable “000”[CR] Response...
PLC-XC56 Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE_%1”[CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
PLC-XC56 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1”[CR] “RST” Reset total lamp running time Details This command is available in normal Power ON status. Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.8.2 CF_LAMPMODE Command Command “CF_LAMPMODE_%1”[CR] “NORMAL”...
PLC-XC56 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1”[CR] “000-063” -------------------------- Directly select Volume setting value “UP” --------------------------------- Current Volume setting value +1 “DN” --------------------------------- Current Volume setting value -1 Control Volume value The same operation of Volume Up/Down as projector and RC, and directly select Volume setting value.
PLC-XC56 Expand Serial Command Functional Specifications 8.10.4 CF_AUTOSETUPPCADJ Command Command “CF_AUTOSETUPPCADJ_%1”[CR] “ON” ------------------- Set Auto PC ADJ. function to ON “OFF” ------------------ Set Auto PC ADJ. function to OFF Set/Cancel Auto PC adj. function This command is available in normal Power ON status. Details Note) It is unable to set Keystone, PC ADJ.
PLC-XC56 Expand Serial Command Functional Specifications 8.10.10 CF_CEIL Command Command “CF_CEIL_%1”[CR] “ON” ------------------------ Set Ceiling to ON “OFF” ----------------------- Set Ceiling to OFF Set/Cancel Ceiling setting. The value set by this command is stored in EEPROM and its setting is effective Details even after ALL is OFF This command is available in normal Power ON status.
PLC-XC56 Expand Serial Command Functional Specifications 8.10.14 CF_P-MANETIME Command Command “CF_P-MANETIME_%1”[CR] “01” ~ ”30” ----------------------- Directly select setting time by the minute “UP” ------------------------------- Plus one minute (01 → 02 → ÿ e ÿ e ÿ e → 30 → 01) ÿ...
PLC-XC56 Expand Serial Command Functional Specifications 8.10.18 CF_PJPINCODE Command Command “CF_PJPINCODE_%1”[CR] “0000” – “9999” ---------Set PJ PIN CODE directly Set PJ PIN CODE to release PJ LOCK. PIN CODE cannot be changed by this command. -When PJ LOCK is in operation PIN CODE is correct ------------------------- Command is valid (Acceptable) PIN CODE is incorrect ----------------------- Command is invalid(Error Code”102”) PIN CODE is out of %1 range ------------- Command is invalid (Error Code “? “)
PLC-XC56 Expand Serial Command Functional Specifications 8.10.21 CF_CCAPTIONCOLOR Command Command “CF_CCAPTIONCOLOR_%1”[CR] “COLOR” ------- Select Color “WHITE” -------- Select White Select color of Closed caption. The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF. Details This command is available in normal Power ON status.
PLC-XC56 Expand Serial Command Functional Specifications 8.10.26 CF_FDEFAULT Command Command “CF_FDEFAULT_%1”[CR] “RST” Set the value to Factory Default Details This command is available in normal Power ON status. Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 38 / 65...
PLC-XC56 Expand Serial Command Functional Specifications 8.11 Other Command 8.11.1 CF_KEYENU Command Command “CF_KEYENU_%1”[CR] “RIGHT” ------------------------- Shift Pointer on OSD Menu to right “LEFT” --------------------------- Shift Pointer on OSD Menu to left “UP” ------------------------------ Shift Pointer on OSD Menu to right “DN”...
PLC-XC56 Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command “CF_FREEZE_%1”[CR] “ON” ------------------------ Set Freeze to ON “OFF” ----------------------- Set Freeze to OFF “UP” ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e ) “DN”...
PLC-XC56 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_Command” [CR] Command : Character Line When projector receives the appropriate command, it returns a character line as the required data “000ÿ...
PLC-XC56 Expand Serial Command Functional Specifications 9.4.3 CR_COLOR Command Command “CR_COLOR”[CR] Details Get Color value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error Code”[CR] 9.4.4 CR_TINT Command Command “CR_TINT”[CR] Details Get Tint value of user control Acceptable “000_%a”[CR] “000”~“063” Response “Error Code”[CR] ----- When the command is invalid due to Unacceptable...
PLC-XC56 Expand Serial Command Functional Specifications 9.4.9 CR_WBAL – B Command Command "CR_WBAL-B”[CR] Details Get White Balance Blue value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error Code”[CR] 9.4.10 CR_COLTEMP Command Command "CR_COLTEMP”[CR] Details Get Color Temp. setting value Acceptable “000_%a”[CR] “000”...
PLC-XC56 Expand Serial Command Functional Specifications 9.4.13 CR_IMAGE Command Command “CR_IMAGE”[CR] Get image setting status Details Required data “CUSTOM1” to “CUSTOM4” is the same as “Image1” to “Image4” displayed when selecting IMAGE on OSD menu Acceptable “000_%a”[CR] “DYNAMIC” --------------------------------------- Dynamic “STAND”...
PLC-XC56 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC”[CR] Details Get Fine Sync value Acceptable “000_%a”[CR] “0000”~“0031” Response “Error Code”[CR] ----- When the command is invalid due to Unacceptable condition such as Input source 9.5.2 CR_TDOTS Command Command...
PLC-XC56 Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command “CR_DDOTS”[CR] Details Get Display Dots value Acceptable “000_%a”[CR] “0256”~“nnnn” Response (nnnn = Total Dots – Horizontal Position value) “Error Code”[CR] -------- When the command is invalid due to Unacceptable condition such as Input source 9.5.7 CR_DLINE Command Command...
PLC-XC56 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS”[CR] Get currently selected signal Details Returns auto-detected signal in Auto mode Only available for Video input. (N/A when Input is computer) Acceptable “000_%a”[CR] “1080I60” -------------- 1080i 60Hz “1080I50”...
PLC-XC56 Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST”[CR] Details Get selectable System titles Acceptable “000_%1_%2_..._%x” [CR] - When Input is PC-Analog “XGA1” ------------ XGA1is selectable “1080I ” ----------- 1080i is selectable Projector does not return Auto,Mode1-5 When there is no signal, it returns Error Code “101” -When Input is PC-Digitalÿ...
PLC-XC56 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get information of Lamp Replacement time Acceptable “000_%1”[CR] “1Y” -------------------------- Over lamp replacement time “1N” -------------------------- Within lamp replacement time “1” means the number of lamps. Response (1 lamp model→...
PLC-XC56 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command “CR_LAMPSTS”[CR] Details Get Lighting status of lamp Acceptable “000_%1”[CR] “n**** ” A number of * should be among 1-4. First character shows how many lamps are incorporated in projector. (1,2 or 4 ) Secound character shows follwing status in order of lamp number.
PLC-XC56 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME”[CR] Details Get Volume value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error Code” [CR] 9.10.2 CR_MUTE Command Command “CR_MUTE”[CR] Details Get sound mute setting status Acceptable “000_%a”[CR] “ON”...
PLC-XC56 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG”[CR] Details Get selected language Acceptable “000_%a”[CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
PLC-XC56 Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
PLC-XC56 Expand Serial Command Functional Specifications 9.11.15 CR_SECURITY Command Command “CR_SECURITY” [CR] Details Get Security Mode setting status Acceptable “000_%1[CR] “ON” ------------- PJ Lock setting on Menu is ON-1 or ON-2 Response “OFF” ------------PJ Lock setting on Menu is OFF Unacceptable “Error Code”...
PLC-XC56 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command “CR_STATUS”(CR) Get status of Projector behavior. Details This command affects the same as ”CR0” of Basic Serial command, but this has an error code. Acceptable “000_%1”[CR] “00”= Power ON “80”= Stand by...
PLC-XC56 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER”[CR] Details Get status of Presentation Timer Acceptable “000_%a”[CR] “ON” -------------------- Presentation timer is in operation Response “STOP” ----------------- Presentation timer is paused “OFF” ------------------- Presentation timer is not operating Unacceptable “Error Code”...
PLC-XC56 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP”[CR] Get current temperature inside a projector. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%1_%2_%3”[CR] %1= Sensor 1 temperature (Outside temperature) %2= Sensor 2 temperature (Inside temperature1) %3= Sensor 3 temperature (Inside temperature2) %1,%2 are consists of 6 bites fixed...
PLC-XC56 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL”[CR] Get the temperature inside a projector when abnormal temperature occurs. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%a_%b_%c”[CR] %a ------------------ Sensor 1 temp.