PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 1. Overview ・ This Functional Specification defines communication with PJ-Net organizer for PLC-XM100 / XM100L / XM150 / XM150L. ・ Supporting Firmware Ver. 1.x of the projector. ・ Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 3. Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_SHARP_%1 [CR] Set value of Sharpness CF_GAMMA_%1 [CR]...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CF_PJPINCODE_%1[CR] Enter PJ PIN code to cancel PJ lock CF_SHUTRCPROT_%1[CR] Set valid / invalid of RC use on Shutter control function Set valid / invalid use of key on the top panel on Shutter CF_SHUTKEYPROT_%1[CR] control function CF_SHUTH_%1[CR]...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_SHARP [CR] Get value of Sharpness...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CR_IDSLOT1[CR] Get ID information of Input1 CR_IDSLOT2[CR] Get ID information of Input2 CR_IDSLOT3[CR] Get ID information of Input3 CR_IDSLOT4[CR] Get ID information of Input4 6.5 Screen Status Read Command Table Status Read command Item CR_SCREEN [CR] Get selected screen size CR_VSCALE[CR]...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CR_P-MANETIME [CR] Get setting time for Power Management CR_STANDBYMODE [CR] Get selected mode of Standby function CR_ON-STA [CR] Get ON Start setting status CR_POINTER[CR] Get setting status of Pointer CR_PTIMEMODE[CR] Get setting mode of P-timer CR_PTIMER[CR] Get status of P-timer CR_PTIME[CR]...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-031”--------------- Directly specify setting value of Sharpness “UP”--------------------- Increment setting value of Sharpness by 1 “DN”--------------------- Decrement setting value of Sharpness by 1 Set user controlled value of Sharpness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ------------------------------ Xlow “001”------------------------------- Low “002”------------------------------- Mid “003”------------------------------- High Set Color Temperature The value set by this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.11 CF_PROGV Command Command “CF_PROGV_%1” [CR] “ON” ----------------- Set Progressive scan to On. “FILM” --------------- Set Progressive scan to Film. “OFF” ---------------- Set Progressive scan to OFF. “UP” ------------------ Switch setting forward direction (OFF→ON→FILM→OFF) “DN”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.13 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4 “STR5”---- Store current adjusted value to Image 5 “STR6”---- Store current adjusted value to Image 6...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.11 CF_PCMODEFREE Command Command “CF_PCMODEFREE_%1” [CR] “1” --------------------------- Set Mode1 to Free status “2” --------------------------- Set Mode2 to Free status “3” --------------------------- Set Mode3 to Free status “4” --------------------------- Set Mode4 to Free status “5”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT 1 Command Command “CF_INPUT1_%1” [CR] “DIGITAL” -------------------------- Select PC Digital Input “ANALOG” ------------------------- Select PC Analog Input “SCART” --------------------------- Select SCART Input “HDCP” ---------------------------- Select DVI HDCP Input Select Input 1 as well as Source specified in %1 (Available only in the normal Details Power ON status) Acceptable...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.9 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Corner correction. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “NORMAL” ------------------------ Set Lamp status to Normal mode “ECO1” ------------------------------- Set Lamp status to Eco1 mode “ECO2” ------------------------------- Set Lamp status to Eco2 mode “AUTO” ----------------------------- Set Lamp status to Auto mode Select Lamp mode (Available only in the normal Power ON status) Details The value set by this command is stored in EEPROM and the setting remains...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000-063” --------------------------- Directly specify value of Volume. “UP” --------------------------------- Increment setting value of Volume by 1 “DN” --------------------------------- Decrement setting value of Volume by 1 Control level of Volume (Available only in the normal Power ON status) Set Volume Up/Down the same way as RC and also directly specify value of Volume.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.4 CF_DISP Command Command “CF_DISP_%1” [CR] “ON” ----------------------------- Set Display to On “CNTDWNOFF” --------------- Set Display to Count down Off “OFF” --------------------------- Set Display to Off “UP” --------------- Switch forward (On → Count down Off → Off → On → ---) “DN”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.14 CF_RSENS Command Command “CF_RSENS_%1” [CR] “ALL” ----------------------------------- Select top, front and back receiver of projector “FRONTTOP” ------------------------ Select front and top receivers of projector “BACKTOP” -------------------------- Select only back and top receivers of projector “FRONTBACK”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.21 CF_PTIMER Command Command “CF_PTIMER_%1” [CR] “START” -------------------------- Start P-timer “STOP” ---------------------------- Stop P-timer “RESTART” ---------------------- Resume P-timer “RST” ------------------------------ Reset P-timer “EXIT” ----------------------------- Exit P-timer function Select the status of P-timer. Details (Available only in the normal Power ON status) Acceptable “000”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.24 CF_PJPINCODE Command Command “CF_PJPINCODE_%1” [CR] “0000 – 9999” ------------- Directly specify PJ PIN code Enter PIN code to cancel PIN code lock (Available only in the normal Power ON status) PIN code can not be changed. (Only PIN code lock is canceled.) *When PIN code Lock is enabled: PIN code is matched ------------------------- Command is valid (Acceptable) PIN code is mismatched -------------------- Command is invalid (Error code “102”)
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.27 CF_SHUTH Command Command “CF_SHUTH_%1” [CR] “005”-“180”----------Specify setting time directly “UP” ------------------ Add 1 minute “DN” ------------------Decrease 1 minute Set time of operating shutter management function. (Valid only when in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.4 CR_TINT Command Command “CR_TINT” [CR] Details Get user controlled value of Tint Acceptable “000_%1” [CR] “000 – 063” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input). “?”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.9 CR_WBAL-B Command Command “CR_WBAL-B” [CR] Details Get user controlled Blue value of White Balance Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.10 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input) “?”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.5 CR_V-POS Command Command “CR_V-POS” [CR] Details Get value of Vertical Position Acceptable “000_%1” [CR] “0000 – nnnn” (nnnn = Total Line – Display area V) Response “Error Code” [CR] ------ When command is not available in the Unacceptable given condition (such as being selected input “?”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-50 is not selected, get the current signal. Acceptable “000_%1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.9 CR_PCSTORE Command Command “CR_PCSTORE” [CR] Get Free or Stored status of MODE1 - 5 in PC Adjust. Details Data consists of 10 bytes and each byte represents MODE1-10. (F:Free, S:Stored) Acceptable “000_%1” [CR] “FFFFFFFFFF”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case for PC-Analog/PC-Digital/AV HDCP signals) Acceptable “000_%1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog; “XGA1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command Command “CR_NMSLOT1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “30” --------------- On-board (DVI-D and D-Sub) Response Available source: DIGITAL, ANALOG, SCART, HDCP Unacceptable “Error Code”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7 CR_CORNERTESTPAT Command Command “CR_CORNERTESTPAT”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME” [CR] Get volume value by user control Details * When input signal is Network, error code “101” is returned. Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.5 CR_LOGO Command Command “CR_LOGO” [CR] Details Get setting status of Logo Acceptable “000_%1” [CR] “DFLT” ----------------------------- Default Logo is enabled Response “USER” --------------------------- User is enabled “OFF” ------------------------------ Logo is disabled Unacceptable “Error Code” [CR] 9.11.6 CR_LOGOLOCK Command Command “CR_LOGOLOCK”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.15 CR_RSENS Command Command “CR_RSENS” [CR] Details Get selected location of infrared remote receiver of remote control Acceptable “000_%1” [CR] “ALL” -------- Select top, front and back receiver of projector “FRONTTOP” ----- Select front and top receiver of projector “BACKTOP”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.20 CR_ON-STA Command Command “CR_ON-STA” [CR] Details Get setting status of Power ON Start Acceptable “000_%1” [CR] “ON” -------------------------- Power ON Start is ON Response “OFF” ------------------------ Power ON Start is OFF Unacceptable “Error Code” [CR] 9.11.21 CR_POINTER Command Command “CR_POINTER”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.25 CR_KEYDIS Command Command “CR_KEYDIS” [CR] Details Get status of RC/KEY (valid or invalid) Acceptable “000_%1” [CR] “NONE” -------------------------- RC and KEY, both are valid Response “RC” ------------------------------- RC is invalid “KEY” ----------------------------- KEY is invalid Unacceptable “Error Code”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.30 CR_SHUTKEYPROT Command Command “CR_SHUTKEYPROT” [CR] Details Get status if Shutter can be controlled by key on the top panel Acceptable “000_%1” [CR] “ON” ------------- Shutter is not controllable by key on the top panel Response “OFF”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.