Permanently lubricated tank mounted air compressor (44 pages)
Summary of Contents for Craftsman 919.167341
Page 1
• Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D27741 Rev 1 8/15/03...
Page 2
HOW TO ORDER REPAIR PARTS ...... back cover ltl__1 ;| ;[_I_ hi" FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
Page 3
Model No. 919-167341 Max. Developed Bore 2.375" Stroke 1.35" Voltage-Single Phase 120V/60HZ Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig E.'ff.,1 =l_lk'd _=-ll]lm]::lmll_l::[,."]mm]=l_ll_lill[o _]_: "] This manual contains information that is important for you to know and understand.
Page 4
I I _ I _o] P, tl IP'.*1 +IIn1[..'9'.*I _1 _ &'d _t _.[.,-]ll[,_[IZe.]llT[o _] _ .[.,_ Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen HOw To Prevent It Failure to properly drain Drain tank daily or after each use.
Page 6
WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions, powered device, If it is not used properly Never operate compressor with it may cause electric shock.
Page 7
WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns, hot for several minutes after operation.
Page 8
WARNING: RISK OF SERIOUS INJURY OR PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR (Fire, Inhalation, Damage to Vehicle Surfaces) WHAT CAN HAPPEN HOW TO PREVENT IT Oil can leak or spill and could result in Always place compressor on e protective mat when transporting fire or breathing hazard;...
Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
E_."_:'] =h_ I :] _'4 Contents of Carton Install the four screws, two on each side. 1 - Air Compressor Tighten securely. Handle Assemble Wheels 1 - Grip Handle 4 - Self Tapping Screw It will be necessary to Wheels brace or support one side of the unit when installing the wheels 2 - Shoulder Bolts, 3/8-16...
Page 11
HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration dry and well ventilated area.
Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
Page 13
Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of vanous controls and adjustments. Save this manua[for future reference. Outlet Pressure Gauge: The outlet Description of Operation...
Motor Overload Protector: The Air Compressor Pump (not shown): Compresses air into the motor has an automatic reset thermal air tank. Working air is not available overload protector. If the motor until the compressor has raised the overheats for any reason, the air tank pressure above that overload protector will shut off the motor.
Page 15
How to Start: Open the drain valve fully (counter-clockwise) to permit air Turn the On/Auto/Off lever to to escape and prevent air "AUTO" and allow tank pressure pressure build up in the air tank during the break-in period. to build. Motor will stop when tank pressure reaches "cut-out"...
Page 16
Customer Responsibilities Before Daily ol after Every Every aach each Yearly hours "_ours Check Safety Valve • Drain Tank • Air Filter •(1) • Air compressor pump intake and exhaust valves • 1- more frequent in dusty or humid conditions Risk of Unsafe TO Check Safety...
Page 17
After the water has been drained, water and squeeze dry. close the drain valve (clockwise). Replace air filter. The air compressor can now be Replace filter cover. stored. NOTE: If the air filter is extremely NOTE: If drain valve is plugged, dirty it will need to be replaced.
Page 18
All maintenance and repair Outlet Tube operations not listed must be performed by Trained Service Technician. Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or Using an adjustable wrench disconnect electrical supply to the...
Page 19
12. Replace the outlet tube and Remove the outlet pressure tighten nuts. gauge, tank pressure gauge, and quick connect (if equipped) from 13. Replace shrouds and console. the regulator. 14. Perform the Break-in Procedure. See "Break-in Procedure" in the Remove the regulator. Operation section.
Page 20
Before you store the air compressor, Risk of Bursting. Water will make sure you do the following: condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and perform scheduled maintenance as necessary.
d:{ollJ :| il ::F,."] -" [oIo]l III _[I Risk of Unsafer Operation. Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
Page 22
PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated )ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
Page 23
PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Motor will start automatically Tank pressure exceeds pressure switch "cut-in"...
Page 24
._ I-'I_o]_V_l *_ -'! _o] -II m] ¥,__:_,__ Air Compressor Model Number 919.167341 D27741 24_ENG...
Page 25
3/8" ACG-18 Saddle Mount Cup (2) 91895680 Screw 1/4 - 20 x .75 (2) ACG-408 Fastener Assembly LA-3027 Label, Drain Tank LA-3069 Label, Craftsman D23402 Label, Performance D23565 Label, Star Rating Z-D26612 Pressure Switch A0-0027-2 Standpipe SSP-480 Nipple 1/4-18 NPT x 2.50...
Page 26
Air Compressor Model Number 919.167341 Torque 7-10 Ft-Lbs The picture shown is for reference only. It may differ from actual unit, 8_80 _ Torque 42-48 ln-Lbs " Terque100-1201n-Lbs 70_ _ _773 Torque 100-120 ImLbs D27741 26_ ENG...
Page 27
Air Compressor Model Number 919.167341 PART NUMBER DESCRIPTION SSF-586 Screw 1/4-20 UNC x .75 AC-0108 SSF-615 Screw 1/4-20 UNC Z-AC-0140 Eccentric Bearing Z-D26712 Motor >X Cylinder Sleeve Connecting Rod Assembly > 79-2 Compression Ring >X 79-3 ACG-29 Connecting Rod Cap >X 79-4 SSF-3158-1...
GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opei6n, Io reparar& o reemplazar& sin eosto alguno.
Page 29
Modelo N ° 919_167340 Max. HP desarrollado Di&metro interior 2,375 po (60,4 mm) Carrera 1,35 po (34,3 mm) Tensi6n monofasica 120V/60HZ Circuito mfnimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 33 Galones (124,9 Iitros) Presi6n de corte de entrada Presi6n de corte de salida SCFM a 40 psig 8,6 Calibre de Iibras...
Page 30
GUARDE ESTAS INSTRUCCIONES LA OPERACI()N O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODR|AN OCASIONAR SERIAS LESIONES Y DAI_IOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. ',,I = ll [_ ;{+ ADVERTENCIA: RIESGO DE EXPLOSI()N O INCENDIO &COMO PREVENIRLO? &QUE...
Page 31
',,I::41 [ _ r,{+ ADVERTENCIA: RIESGO DE EXPLOSION TANQUE AIRE: SIGUIENTES CONDICIONES PODRiAN, CAUSAR DEBlUTAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSION VIOLENTA, DAI_IOS A LA PROPIEDAD O SERIAS LESIONES. &QUE PUEDE OCURRIR? _.COMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamenta o despu_s en el tanque,...
Page 32
ADVERTENCIA: RIESGO DE DESCARGA ELECTRICA &QUEPUEDE OCURRIR? &COMO PREVENIRLO? Su compresor de aire est& accionado per Jam&s opere e! compresor a la intemperie cuando est& Iloviendo o en condiciones electricidad. Come cualquier otto dispositivo humedad. et6ctrico impulsado electricamente, si no se Io utiliza adecuadamente, podria causarle Nunca opere el compresor...
Page 33
ADVERTENCIA: RIESGO DE QUEMADURAS _QU I_ PUEDE OCURRIR? _COMO PREVENIRLO? Jamds toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmed+atamente despues del compresor o los tubos de saI+da del escape, de la operaci6n, el compresor permanecer_...
Page 34
'.,l =1 al[_ r.{q ADVERTENCIA: RIESGO DE DAI_OS A LA PROPIEDAD TRANSPORTAR EL COMPRESOR (Fuego, inhalacibn, daho a la superficie de veh_culos) &QUE PUEDE OCURRIR? &COMO PREVENIRLO? El aceite puede derramarse y ello podr_a Deposite el compresor sobre una alfombrilla resultar en serias lesiones o la muerte debido aI protectora cuando lo transporte,...
Page 35
Presibn minima de corte: Cuando el Familiadcese con los siguiantes t_rminos, motor est& apagado, la presiSn del tanque antes de oparar la unidad: de aire baja a medida que usted contint_a CFM: (Cubic feet per minute) Pies cQbicos usando su accesorio. Cuando la presi6n pot minuto.
Page 36
Contenido de la caja Inserte la mango en la montura del compresor y alinee los orificios de 1- Compresor de aire los dos tomillos a cada lado. 1- Manija Instale los cuatro tomillos, dos a 1- Agarradera de manija cada lado. 4- Tomillo Autorroscante _u_efirmemen_.
Page 37
COMO PREPARAR LA UNIDAD Aseg0rese de que el tomaconie_te que sera utilizado tenga la misma Ubicacibn del comp_sor de aire con&:juraci6n que el enchufe de conexi6n a tierra Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. Ver Iimpi&...
Page 38
Cables de extensibn eldctrica Proteccibn del voltaje y del circuito No se recomienda la utilizacion de cables Acerca del voltaje y la minima cantidad de de extensi6n el_ctrica. El uso de cables circuitos requeridos, refierase al cuadro de extensi6n el_ctrica originar& una caida de especificaciones.
Page 39
Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones Conserve este manual para referencias futuras.
Page 40
Valvula reguladora: Cuando el Protecci6n pera sobrecarga del motor: compresor El motor tieae un protector de sobrecarga Bite se termico de reposicion autom&tica. Si el encueatra motor se sobrecalienta pot alguna razon, funcionando, el protector de sobrecarga apagar& el valvule motor.
Page 41
Mueva la palanca On/Auto/Off ala Cdmo poner en marcha: posici6n "ON/AUTO". El compresor se Mueva la palanca On/Auto/Off ala pondr& en marcha. posici6n "AUTO" y deje que se Haga funcionar el compresor durante 15 incremente la presi6n del tanque. El minatos.
Page 42
Responsabilidades del cliente Antes Diadanente Cada Cada Anualmente de cada o luego de cada use horas horas Verifique la v&lvula de seguridad Drenaje de{ tanque O(1) • Filtro de aire Valvulas de entrada y escape de la bomba del compresor de aire 1- M&s frecuente en condiciones...
Page 43
Si est& sucio enjuague el filtre de aire Riesgo de con agua tibia y exprfmalo hasta que Explosibn. Dentro del tanque se producira condensaci6n seque. Reponga el filtro de aire y su reten. de agua. Si no drena, el agua Io corroera y debilitard causando un NOTA: Si el flltre de aire est&...
Page 44
Todo tipo de mantenimiento y operaciones de rsparacibn mencionados, deberan set efectuados pot personal t_cnico especielizado. Riesgo de Operacidn Insegura: La unidad arranca automaticamente cuando esta enchufada. AI hecer el mentenimiento, el operador puede quedar expuesto a fuentes de corriente y de airs compdmido o a piezas movibles.
Page 45
Vuelva a instalar la tuberia de salida y la conexion r&pida (si estuviese ajuste las tuercas. equipada) del regulador. Reponga el recubrimiento y la Extraiga el regulator. consola. Aplique sellador para ca£_os al niple. Ejecute el procedimiento de puesta en marcha. Yea "Procedimiento Puesta en Marcha"...
Page 46
Antes de guarder su eompresor de aire, Riesgo de asegQrese de hacer Io siguiente: Explosibn. El agua se condensa dentro del tanque de 1< Revise la secci6n "Mantenimiento" aire. Si no se drene, ella de las p&ginas precedentes y ejecute el mantenimiento programado corroerd debilitando...
Page 47
[_l_.,_ Im] _ I m] p ';l_] Z [T_--]lli[o,,[o] I m] " _ I _ :To]=]nil : 4i_Y;%,."] Riesgo de Operacibn Insegura: La unidad arranca automaticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles.
Page 48
PROBLEMA CORRECCION CAUSA Si habiese una caida excesiva de La lectura de la Es normal que ocurra algen presidn durante el uso del descenso en la presion. presion sobre an accesorio, aiaste el regulador mandmetro acuerdo alas instrucciones de la viene equipado seccion Operaci6n.
Page 49
CAUSA CORRECCION PROBLEMA El motor no El interruptor de protecci6n Deje enfriar el motor y el funciona. interruptor de sobrecarga se obrecarga del motor se ha abierto< reajustar& autom&ticamente El motor arrancar& automaticamente La presi6n del tanque excede la presion de "corte maximo" cuando la presi6n del tanque caiga For debajo de la presi6n de corte del interruptor...
Repair Protection Agreements Contratos de Proteccibn para Reparaciones Congratulations on making a smart purchase. Your new Craftsman <_' product is Felicitaciones per hater una compra designed and manufactured for years of inteligente, Su nueva unidad Craftsman _) est& dependable operation.
Page 52
and items like garage door openers and water heaters. 1-800-4-MY-HOME ® Anytime, day or night (1-800-469-4663) (U.S.A.and Canada) www.sears.com www.sears.ca Our Home For repair of carry-in products like vacuums, lawn equipment, and electronics, call or go on-line for the nearest Sears Parts and Repair Center.