Installing the Z9000 System
Publication Date: October 2012

Advertisement

Table of Contents
loading

Summary of Contents for Dell Force10 Z9000

  • Page 1 Installing the Z9000 System Publication Date: October 2012...
  • Page 2 © 2012 Dell Force10. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell(™), the DELL logo, Dell Boomi(™), Dell Precision(™), OptiPlex(™), Latitude(™), PowerEdge(™), PowerVault(™), PowerConnect (™), OpenManage(™), EqualLogic(™), Compellent(™), KACE(™), FlexAddress(™), Force10(™) and...
  • Page 3: Table Of Contents

    Contents 1 Preface About this Guide ........... . . 7 Related Publications .
  • Page 4 Install a Power Supply..........27 Install a New AC Power Supply .
  • Page 5 9 Technical Support The iSupport Website ..........51 Accessing iSupport Services .
  • Page 6 Contents...
  • Page 7: Preface

    Command Line Interface (CLI) information, refer to the FTOS Command Line Reference Guide for the Z9000 System. NOTE: The Z9000 system requires, at a minimum, Dell Force10 Operating System (FTOS) version 8.3.11.0. CAUTION: Wear grounding wrist straps when handling this equipment to avoid Electrostatic Discharge (ESD) damage.
  • Page 8 Preface...
  • Page 9: The Z9000 System

    The Z9000 System Introduction The Dell Force10 Z9000 platform is a next-generation switch/router product designed to meet the requirements for distributed data center cores. It is a two-rack unit (RU) chassis that supports 32 ports of 40GE QSFP+ or 128 ports of 10GE SFP+ (with breakout cables). The Z9000 includes an RS-232 console port and a management port for system access.
  • Page 10: Orderable Z9000 Components

    You can order the Z9000 in several different configurations. You can also order optional modules and optics separately. Table 2-1. Supported Hardware Components Hardware Force10 Catalog Number Dell Part Number 32-port 40G QSFP+ ports, 1 AC power supply, 1 fan subsystem Z9000-AC K9N70 (airflow from the I/O side to the power supply side)
  • Page 11: Features

    To successfully install the Z9000, ensure that you have the following: • Z9000 chassis • Optics (Optics must be ordered separately, they do NOT come with the base system.) • At least one grounded power source per chassis • Cable to connect the power source to the chassis (included) •...
  • Page 12: Ports

    Ports • External serial RS-232 port (RJ45 type) • Remote management port • 32-port 40G QSFP+ ports • USB-A port • USB-B port • SSD drive System Status You can view the Z9000 status information in several ways, including Light Emitting Diodes (LEDs) and boot menu options.
  • Page 13 The Z9000 system LEDs are: • System status (SYS) • Power status (PSU) • Alarm status (ALM) • System locator beacon (LOC) • System reset (Reset) Table 2-3. System LED Displays Label LED Color/Display Description System status (SYS) No power Located on I/O panel Green solid Normal operation...
  • Page 14 Table 2-4. Port LED Displays Feature Description QSFP+ Port LED Link LED: • Green—Link up on this port When the QSFP+ ports are operating in 40G mode, the left-most LED is lit. When the ports are operating in 4x10G mode, only the LEDs associated with an active port are lit.
  • Page 15: Site Preparations

    NOTE: Install the Z9000 chassis into a rack or cabinet before installing any optional components. Site Selection Dell Force10 equipment is intended for installation in restricted access areas. A restricted access area is one in which access can only be gained by service personnel through the use of a special tool, lock, key, or other means of security and access is controlled by the authority responsible for the location.
  • Page 16: Cabinet Placement

    Cabinet Placement Only install the Z9000 in an indoor cabinet designed for use in a controlled environment (as described in Site Selection). Do not install the Z9000 in an outside plant cabinet. The cabinet must meet the following criteria: • Minimum cabinet size and airflow according to the Electronic Industries Alliance (EIA) standard. •...
  • Page 17: Storing Components

    Storing Components If you do not install your system and components immediately, Dell Force10 recommends properly storing the Z9000 and all optional components until you are ready to install them. WARNING: Electrostatic discharge (ESD) damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the Z9000 and its accessories.
  • Page 18 Site Preparations...
  • Page 19: Install The Z9000

    Install the Z9000 To install the Z9000 system, Dell Force10 recommends completing the installation procedures in the order presented below. Always handle the system and its components with care. Avoid dropping the Z9000 or its Field Replaceable Units (FRUs). This chapter describes the installation procedures as follows:...
  • Page 20: Install The System Into The Rack Or Cabinet

    To install the system into a two-post 19-inch equipment rack using the already attached mounting brackets, follow these steps: Step Task NOTE: Dell Force10 recommends using one person to hold the Z9000 in place while another person attaches the brackets to the posts. Install the Z9000...
  • Page 21: Attach The Ground Cable

    Use a single M4x0.7 screw to attach the ground cable to the system. The cable itself is not included with the Z9000. To properly ground the system, Dell Force10 recommends using a 6AWG one-hole lug, #10 hole size, 63" spacing (not included in shipping). The one-hole lug must be a UL recognized, crimp-type lug.
  • Page 22: Install The Qsfp+ Optics

    Step Task (continued) As shown, attach the one-hole lug to the system using the supplied screw with the captive internal tooth lock washer. Torque the screw to 20 in-lbs. Grounding point 40G/4x10G QSFP+ ports Attach the other end of the ground cable to a suitable ground point. The rack installation “ears” are not a suitable grounding point.
  • Page 23: Splitting Qsfp Ports To Sfp+ Ports

    Z9000 system and is located in a slot on the lower-right area on the I/O side as shown in the following figure. The SSD is field replaceable but not hot-swappable and supports drives that use 12 Volts and/or 5.0 Volts. Be sure to use only drives supported by Dell Force10. Install the Z9000...
  • Page 24: Remove The Solid State Drive

    Supply Power and Power Up the System Supply power to the Z9000 after the system is mounted in a rack or cabinet. Dell Force10 recommends re-inspecting your system prior to powering up. Verify that: • the equipment is properly secured to the rack and properly grounded.
  • Page 25: Power Up Sequence

    WARNING: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the Z9000 system and its components. Power Up Sequence When the system powers up, the fans come on at high speed. The fan speed slows as the system boots up. The SYS Light Emitting Diode (LED) does not light up until the boot-up sequence is complete.
  • Page 26 Install the Z9000...
  • Page 27: Power Supplies

    PSU. NOTE: If you use a single PSU, you must install a blank plate in the other PSU slot. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot.
  • Page 28: Install A New Ac Power Supply

    CAUTION: Be sure that the DC power source is turned off before attaching the cables to the DC connectors on the Z9000. Power Supply 0 (PSU0) is on the top of the Z9000; power supply 1(PSU1) is on the bottom of the Z9000 system.
  • Page 29: Replace A Power Supply

    Requesting a Hardware Replacement. NOTE: If you use a single PSU, you must install a blank plate in the other PSU slot. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot. Replace an AC Power Supply To replace an AC PSU, follow these steps: NOTE: The PSU slides into the slot smoothly.
  • Page 30: Replace A Dc Power Supply

    Replace a DC Power Supply To replace a DC power supply, follow these steps: NOTE: The PSU slides into the slot smoothly. Do not force the PSU into a slot as this may damage the PSU or the chassis. Step Task Turn the DC power source OFF.
  • Page 31: Fans

    Components • Z9000 Fan module (Force10 Catalog# Z9000-FAN | Dell Part # WWJVT) • Z9000 Fan module - Reverse flow (Force10 Catalog# Z9000-FAN-R | Dell Part # FRD2C) Install a Fan Module The fan modules in the Z9000 are field replaceable. Module Slot 0 is on the left; Module Slot 3 is on the right.
  • Page 32 To install a new fan module, follow these steps: Step Task Twist the latching screws so that the fan screen detaches from the system as shown in the following figure. Fan modules PSU0 PSU1 Latching screw Latching screw Fan screen Remove the screen and set it aside.
  • Page 33: Replace A Fan Module

    Replace a Fan Module To replace a fan module, follow these steps: Step Task Twist the latching screws so that the fan screen detaches from the system. PSU0 Fan Module 0 Fan Module 1 Fan Module 2 Fan Module 3 Grab Handle PSU1 Screw...
  • Page 34 Fans...
  • Page 35: Access Ports

    Access Ports The Z9000 has two management ports available for system access—a console port and a Universal Serial Bus (USB)-B port. The USB-B ports act exactly the same as the console port. The terminal settings are the same for both access ports. Access the RJ-45/RS-232 Console Port On the I/O side of the Z9000 system, the RJ-45/RS-232 console port is labeled in the upper right-hand corner as shown in the following figure.
  • Page 36: Access The Rj-45/Rs-232 Console Port With A Db-9 Adapter

    USB-B Port NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC. You will also need the appropriate drivers for the USB device you use. For assistance, contact Dell Force10 Technical Support.
  • Page 37: Access The Solid State Drive

    Step Task Power on the PC (Dell Force 10 recommends using the XP operating system). Connect the USB-A end of cable into an available USB port on the PC. Connect the USB-B end of cable into the USB-B console port on the Z9000.
  • Page 38: Components

    Figure 7-3. SSD Drive Handle Components The following SSD option is available: • Z9000 Solid State Drive (Force10 Catalog# Z9000-SSD | Dell Part Number: 2HYHT) Install an SSD To install an SSD, follow these steps: Step Task Shut down the system. You cannot hot-swap the SSD; you must reboot the system to recognize a new or reseated SSD.
  • Page 39: Copy Files To And From The Ssd

    drw- 8192 Mar 30 1919 10:31:04 CORE_DUMP_DIR d--- 8192 Mar 30 1919 10:31:04 ADMIN_DIR --More-- Copy Files to and from the SSD To copy files to or from the SSD, use the command. For example: copy Copy from an FTP site to the SSD: FTOS#copy ftp://myusername:mypassword@10.10.10.10//FTOS/FTOS-ZB-8.3.11.0.bin slot0:/ Destination file name [FTOS-ZB-8.3.11.0.bin.bin]: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  • Page 40 Access Ports...
  • Page 41: Specifications

    Specifications This chapter contains the following sections: • Chassis Physical Design • Agency Compliance Chassis Physical Design Parameter Specifications Height 3.48 inches (8.8 cm) Width 17.32 inches (44.0 cm) Depth 24.00 inches (61.00 cm) Chassis weight 50.3 lbs (approx.) (22.8 kg) Rack clearance required Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm)
  • Page 42: Dc Power Requirements

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Dell Force10 is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment.
  • Page 43: Canadian Department Of Communication Statement

    This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell Force10 can not accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell Force10 option cards.
  • Page 44: Korean Certification Of Compliance

    WARNING: Use the AC Power cords with Dell Force10 equipment only. Do not use Dell Force10 AC power cords with any unauthorized hardware. Korean Certification of Compliance Korean Package Label Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 2nd Edition •...
  • Page 45: Electromagnetic Compatibility (Emc)

    Force10 encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell Force10 offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
  • Page 46 EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell Force10 products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE.
  • Page 47: Battery Replacement

    The lithium battery is not field replaceable. Only authorized personnel should remove and replace the lithium battery. If the battery requires replacement, contact Dell Force10 Technical Support. WARNING: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the Z9000 and its components.
  • Page 48 Customer participation is important to minimize any potential effects of batteries and accumulators on the environment and human health due to the potential presence of hazardous substances. For proper collection and treatment, contact your local Dell Force10 representative. Specifications...
  • Page 49: For California

    Figure 8-1. The European WEEE Symbol For California: Perchlorate Material—Special handling may apply. For more information, refer to: http://www.dtsc.ca.gov/hazardouswaste/perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. Specifications...
  • Page 50 Specifications...
  • Page 51: Technical Support

    Requesting a Hardware Replacement The iSupport Website iSupport provides a range of documents and tools to assist you with effectively using Dell Force10 equipment and mitigating the impact of network outages. Through iSupport you can obtain technical information regarding Dell Force10 products, access to software upgrades and patches, and open and manage your Technical Assistance Center (TAC) cases.
  • Page 52: Contacting The Technical Assistance Center

    Contacting the Technical Assistance Center How to Contact Dell Force10 Log in to iSupport at http://www.force10networks.com/support/ and select the Service Request tab. Information to Submit When • Your name, company name, phone number, and E-mail address Opening a Support Case •...
  • Page 53: Requesting A Hardware Replacement

    Center). Provide the following information when using E-mail or phone: • Part number, description, serial number (required), Dell Service Tag (required) and chassis color (required) of the component. • Your name, organization name, telephone number, fax number, and E-mail address.
  • Page 54 Technical Support...
  • Page 56 Printed in the U.S.A. w w w. d e l l . c o m | s u p p o r t . d e l l . c o m...