Page 3
Table of Contents Model Series Features Installation Highlights Top and Front Panel Removal Door Gasket and Handle Drum Glide and Upper Seal Lower Drum Seal Drum Removal Drum Shaft and Bearing Start Switch Temperature Selector Switch Timer Door Switch Control Thermostat and Heater High Limit Thermostat Thermal Limiter Heat Systems...
Page 4
Model Features DBL333EY/GY - GE 5.7 Cu. Ft. Large Capacity Dryer Features and Benefits DCL333EY/GY - GE 5.7 Cu. Ft. Large Capacity Dryer Features and Benefits...
Page 5
DVL223EY/GY - GE 5.7 Cu. Ft. Large Capacity Dryer Features and Benefits ™ Model Nomenclature...
Page 6
Installation Specifications Electric Dryer Exhaust Options: Circuit Requirements: Electric Dryer Rating: Note: Installation Information: Gas Dryer Exhaust Options: Circuit Requirements: Gas Dryer Electric Rating: Gas (BTU/HR):...
Page 7
Exhaust Ducting Length • DO NOT • NOTE: When exhausting from the side or bottom, a vent kit is available as publication #14-A018. The vent kit replaces the existing duct inside the dryer to allow a 90° elbow to vent the dryer out the side or bottom. The kit consists of a 6 1/2” long, 4” diameter metal duct with attached mounted bracket and instructions.
Page 8
DRYER OPERATION 2 Phillips screws The dryer drum rotates clockwise at 48 – 54 rpm as viewed from front. On electric models, air is drawn into the heater housing and across the open coils of the electric heater. On gas models, air is drawn into the combustion chamber and over the burner flame.
Page 9
Apply a bead of WH60X20 adhesive on the air duct Rear Access Panel seal and position it on the air duct. Reinstall the lint trap cover and filter, front and top panel. The rear access panel allows access to view the motor, centrifugal switch, idler pulley assembly, belt and belt switch.
Page 10
Dryer Drum Removal Drum Bearing To remove the dryer drum, disconnect power and The drum bearing mounts to the inside rear of the remove the top and front panels. Next, remove the dryer cabinet by means of a sheet metal bracket yellow spacer/bumper attached to the top cross secured by two 5/16”...
Page 11
Temperature Selector Switch The rotary temperature selector switch, one of the controls on the model DBL333, allows the customer to select different temperature settings for drying. The switch contains a 3K ohm resistor on the electric model and a 2.4K ohm resistor on the gas model.
Page 12
Door Switch Depending on the dryer model, the timer can have one or two resistors connected to it. Refer to the wiring diagram with the dryer. The door switch is a normally open switch wired in series with the drive motor. When the door is closed and the motor running, a circuit is completed through the motor’s run winding.
Page 13
To check the control thermostat, remove the wiring from the terminals. At room temperature, the thermostat should have continuity between the control thermostat terminals. To check the bias heater, remove the wiring from the bias heater THERMAL terminals. Check the resistance between the bias LIMITER heater terminals.
Page 14
by removing the drum and visually inspecting the Belt Switch element for breaks. Remove the leads from the heater terminals and check for 12 ohms across the The belt switch is a normally closed switch and is terminals, then check each terminal to ground. If mounted on the motor bracket next to the idler arm.
Page 15
The motor contains a centrifugal switch which serves tape, two Phillips screws and the six clips holding three purposes: It disengages the motor start the cover in place.Note the retaining clips under the winding, engages the motor run winding and closes aluminum tape at the bottom edge of the cover.
Page 16
Next, remove the fan housing lock from the rear of the blower housing. HOUSING LOCK MOTOR AND HARNESS WIRING INTERNAL MOTOR WIRING YELLOW ORANGE BLACK TERMINALS To remove the lock, insert a flat bade screwdriver as shown below. Pry the lock away from the housing far enough to clear the retaining tab and lift the lock out of the channel.
Page 23
Dryer Will Not Run Gas Dryer Electric Dryer House fuse, House fuse, Adequate voltage Adequate voltage breaker, outlet breaker, outlet to dryer? to dryer? problem problem Connections at Replace door Door switch Repair terminal terminal block switch contacts closed? block connection. Replace start Start switch Replace door...
Page 24
No Heat - Drum Turns Electric Dryer House fuse, Adequate voltage breaker, wall to dryer at outlet? outlet problem Correct voltage at Replace power dryer terminal cord block? Turn timer on Contacts A & B Replace timer closed on the timer? Contacts 1 &...
Page 25
No Heat - Drum Turns Gas Dryer Ignitor glowing? Replace flame Flame sensor Gas supply OK Fix supply sensor contacts closed? to dryer? problem Ignitor between Contacts A & B 50 and 400 ohms Replace timer closed on the Replace ignitor at room timer? temperature?
Page 26
No Medium Heat Electric and Gas Dryers Continuity between contacts Replace 1 & 2 and 3 & 4 temperature on temperature selector switch selector switch? Resistor on Replace temperature temperature selector selector switch switch open? resistor Resistor between Replace timer contacts resistor E &...
Page 27
Timer Will Not Advance On Auto-Cycle Electric Dryer Timer advances but doesn't complete cycle? Advance timer to Turn timer on near end of cycle. Continuity Continuity Replace timer between timer between timer Replace timer contacts TM & X contacts and between B &...
Page 29
GE - DBL333EY0WW (ELECTRIC DRYER - CONTROLS AND TOP PANEL) Ref No Part Number Description 49-9996 USE & CARE MANUAL 31-15408 MINI MANUAL WE02X10009 CLIP-TOP/FRONT PANEL WE02X10021 SCR, 8-18 X .50 WE20X10010 PANEL BACK WE04X10037 SELECTOR SWITCH WE04X10033 SWITCH-START WE19X10024...
Page 35