Demolition Hammer Model H 60MRV Handling instructions Note: Before using this Electric Power Tool, carefully read through these HANDLING INSTRUCTIONS to ensure efficient, safe operation. It is recommended that these INSTRUCTIONS be kept readily available as an important reference when using this power tool.
d) Remove any adjusting key or wrench before turning GENERAL SAFETY RULES the power tool on. A wrench or a key left attached to a rotating part WARNING! of the power tool may result in personal injury. Read all instructions e) Do not overreach.
PRECAUTIONS ON USING DEMOLITION HAMMER 4. Wear a mask when turning your head upward. 1. Wear earplugs to protect your ears during operation. 5. Properly set the bit holder 2. Do not touch the bit during or immediately after 6. At the start of work, confirm screw tightening. operation.
Page 4
2. Power switch (2) Release grip (B) and turn the tool, and make sure Ensure that the power switch is in the OFF position. that it is locked completely. If the plug is connected to a receptacle while the power switch is in the ON position, the power tool Grip (A) will start operating immediately, which could cause a serious accident.
1. Grease Replacement Period After purchase, replace grease after every 6 months of usage. Ask for grease replacement at the nearest Hitachi Authorized Service Center. In the case that you are forced to change the grease by yourself, please follow the following points.