hit counter script

Hydraulic Solenoid Valve Coils; Specifications 6 - Toro Groundsmaster 4000-D Service Manual

Hide thumbs Also See for Groundsmaster 4000-D:
Table of Contents

Advertisement

Hydraulic Solenoid Valve Coils

RIGHT
FRONT
1. Front PTO manifold
2. RH PTO manifold
Several hydraulic solenoid valve coils are used on the
hydraulic control manifolds of Groundsmaster 4000--D
and 4010--D machines. When energized by the TEC
controller, these coils provide hydraulic circuit control.
Solenoid valve coils with two (2) different resistance
specifications are used on the 4000--D and 4010--D.
The correct resistance of a coil can be identified by mea-
suring the height and diameter of the coil (Fig. 67). Re-
sistance testing of the coils can be done with the coil
remaining on the hydraulic valve.
Electrical System
4
1
Figure 66
3. LH PTO manifold
Page 5 - - 52
4. Combination manifold
NOTE: To assist in troubleshooting, identical solenoid
coils can be exchanged. If the problem follows the ex-
changed coil, a problem with the coil likely exists. If the
problem remains unchanged, something other than the
solenoid coil is the problem source (e.g. switch, circuit
wiring, hydraulic problem). Refer to your parts catalog to
determine if solenoid coils are identical.
Groundsmaster 4000--D/4010--D
2
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30603Groundsmaster 4010-d306053060730609

Table of Contents

Save PDF