hit counter script

Advertisement

Installation Instructions
DA5960 W
Read these instructions and the "Important Safety Instructions" before installing
this hood.
Installation, repair and maintenance work should be performed by a
Miele authorized service technician in accordance with national and
local safety regulations and the provided installation instructions.
en-CA

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA5960 W

  • Page 1 Read these instructions and the "Important Safety Instructions" before installing this hood. Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
  • Page 2: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 3: Appliance Dimensions

    Appliance dimensions...
  • Page 4 If this is the case the filter needs to be turned 180° and inserted the other way round. Les appareils de Miele peuvent être encastrés à ras ou avec débordement. Discutez de vos conditions d'installation avec votre architecte, décorateur de l'intérieure et installateur.
  • Page 5 If there is more than one appliance Miele cooktops: beneath the hood and they have - 24" (610 mm) above electric different minimum safety distances surfaces, always select the greater distance.
  • Page 6 Appliance dimensions Use the following distances when preparing a rear wall (screw ø 5 mm). *The middle retaining plate can vary in position, depending on the ventilation gap and the position of the outlet. It should be mounted as low as possible. If the exhaust hood is being mounted directly on the wall, follow the enclosed assembly.
  • Page 7: Installation Accessories

    Installation accessories dai2417...
  • Page 8 Installation accessories a 3 protective shields to prevent scratches to the chimney during installation. 8 large headed screws 5 x 40 mm b 2 hose clips for securing the retaining plates and the for securing the ducting. canopy c 1 reducing collar (S8 wall anchors included in the for use with 5"...
  • Page 9: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 10: Installation

    Installation Installation instructions Dismantling ^ See the enclosed installation If the hood needs to be disassembled, instruction diagram. follow the instructions on the installation diagram in the reverse order. ^ Please read the "Important Safety Instructions" and Installation A lever is enclosed for easier removal instructions before installing this of the chimney extension.
  • Page 11: Air Extraction

    Air extraction Exhaust ducting and connections WARNING – The ducting should be as short and straight as possible, and the number Danger of toxic fumes. of sharp bends should be minimized. Gas cooking appliances release – For most efficient air extraction, the diameter of the ductwork should not carbon monoxide that can be be less than 6"...
  • Page 12: Condensate Trap

    Air extraction Condensate trap optional accessory In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur. This optional accessory is available for ducts 5" (125 mm) and 6" (150 mm) in diameter. –...
  • Page 13: Electrical Connection

    To increase security before the electrical connection of this appliance machine is installed, it is to your power supply, please consult a recommended to install a protective licensed electrician or contact Miele’s switch (30 mA). Technical Service Department. Important (Canada only) ,WARNING:...
  • Page 14: Technical Data

    Technical data Maximum load ....400 W Fan ..... . 350 W Overhead lighting .
  • Page 15 Alteration rights reserved / 1209 M.-Nr. 07 598 240 / 00 For the most updated manual see the Miele web site.

Table of Contents