Parameterizing
5.2 Data communication between client and RF182C
● If no configuration message frame is sent and the default port setting was not changed
38
via the web server, the RF182C is operated in the default setting.
The default values are shown in the following figure:
Figure 5-2
Default settings of the RF182C
Parameter
Baud rate
Port 10001
Port 10002
Asynchronous message frames
(alarm/presence message) are assigned to the
opened port.
LED suppression
Mode
NOTICE
SLG D11S and D12S cannot run with the standard baud rate
Please note that the MOBY D readers SLG D11S and D12S cannot run if the standard
baud rate is set.
If you want to operate these readers with the communication module, you must first
parameterize the communication module and set the baud rate to 19.2 kBaud.
Value
115.2 kBaud
Reader 1 assignment (see chapter Web server
(Page 41))
Reader 2 assignment (see chapter Web server
(Page 41))
NONE
U/D/RF300/RF600
RF182C communication module
Operating Instructions, 10/2010