16
www.aeg.com
4. TROUBLESHOOTING
Some problems can be caused either as the results of simple maintenance operations
or by incorrect selection of settings. Prior to contacting a Service Centre please check
the following chart.
Problem
The appliance is not
working
The electric oven is not
working
The thermostat is not
working
The electric thermostat
warning light does not
switch on during use
The oven light does not
switch on
5. INSTALLATION
5.1Technical information
Warning: Alwais use safety gloves
while handling the cooker.
•
The installation, adjustments,
conversions and maintenance
operations listed in this part must
only be carried out by qualified
personnel. The manufacturer
cannot be held responsible for any
damage to persons or property
resulting from an incorrect
installation of the appliance.
•
The safety and automatic adjustment
devices of the appliances may,
during its life, only be modified by
the manufacturer or duly authorised
supplier.
•
In accordance with the gas standard,
the all-gas and combi appliances are
"class 1" (free standing) or "class 2
subclass 1" (recessed) and, as such,
must comply with the clearances
specified in figure below consequently
Remedy
•
Make sure the gas tap is open
•
Check the plug is in
•
Check that the knobs are set correctly for cooking and
then repeat the operations given in the handbook
•
Check the electrical system safety switches (RCD). If there
is failure in the system call an electrician in.
•
Check that the programmer accessory, if there is one, is
on the manual position and then repeat the operations
described in the manual
•
Contact Service Centre .
•
Turn the thermostat round to a hotter temperature
•
Turn the selector round to a different function
•
Make sure the lamp is firmly screwed in place
•
Buy a lamp for high temperatures at one of our Service
Centre and fit it following the instructions given "Replacing
the oven lamp" paragraph.
•
•
•
Installation
Unpacking your cooker
•
any side walls must be no higher than
the work top.
The walls adjacent to and
surrounding the appliances must be
able to withstand an temperature of
95°C.
The installation of all-gas and combi
appliances must comply with the
standards in force.
This appliance is not connected to a
flue for discharge of the combustion
products; therefore, it must be
connected in compliance with the
above mentioned installation rules.
Particular attention must be paid
to the instructions given below for
ventilation and aeration.
Once the wrapping has been
removed from the outer surfaces and
the various inner parts, thoroughly