6.15 Adjustment of the Finisher (MJ-1033)

Notes:
Before performing each adjustment, make sure that all covers (incl. those of the finisher and
equipment) are closed. Otherwise, no power is supplied to the Finisher and the adjustment may
not be performed properly.
6.15.1

Saddle stitching position adjustment

[A] Saddle stitching position adjustment (LD/A3)
This adjustment is performed in the Adjustment Mode (05-4820-0) of the equipment.
Adjustment scale
Adjustable range
Adjustment direction
[B] Saddle stitching position adjustment (LG/B4, 8K, A4-R/LT-R, 16K-R)
This adjustment is performed in the Adjustment Mode (05-4820-1) of the equipment.
Adjustment scale
Adjustable range
Adjustment direction
6.15.2

Saddle stitch folding position adjustment

[A] Saddle stitch folding position adjustment (LD/A3)
This adjustment is performed in the Adjustment Mode (05-4821-0) of the equipment.
Adjustment scale
Adjustable range
Adjustment direction
[B] Saddle stitch folding position adjustment (LG/B4, 8K, A4-R/LT-R, 16K-R)
This adjustment is performed in the Adjustment Mode (05-4821-1) of the equipment.
Adjustment scale
Adjustable range
Adjustment direction
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
0.2mm
-3.4 mm to 3.4 mm
Increasing the value
The stitching position moves downward against the
center position.
Decreasing the value
The stitching position moves upward against the
center position.
0.2mm
-3.4 mm to 3.4 mm
Increasing the value
The stitching position moves downward against the
center position.
Decreasing the value
The stitching position moves upward against the
center position.
0.2mm
-3.4 mm to 3.4 mm
Increasing the value
The folding position moves downward against the
center position.
Decreasing the value
The folding position moves upward against the
center position.
0.2mm
-3.4 mm to 3.4 mm
Increasing the value
The folding position moves downward against the
center position.
Decreasing the value
The folding position moves upward against the
center position.
6 - 89