hit counter script
Siemens SIMATIC IPC647D Operating Instructions Manual

Siemens SIMATIC IPC647D Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC647D:

Advertisement

SIMATIC IPC647D/847D Hardware
RAID Configuration
SIMATIC IPC647D/847D Hardware
RAID Configuration
Compact Operating Instructions
08/2014
A5E34655907-AA
___________________
Preface
___________________
Overview
___________________
Safety information
___________________
Commissioning the device
Expanding the device and
___________
assigning the device
parameters
___________________
Maintaining and repairing the
device
___________________
Technical specifications
___________________
Technical support
1
2
3
4
5
6
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC647D

  • Page 1 ___________________ SIMATIC IPC647D/847D Hardware Preface RAID Configuration ___________________ Overview ___________________ Safety information ___________________ Commissioning the device SIMATIC IPC647D/847D Hardware Expanding the device and ___________ assigning the device RAID Configuration parameters ___________________ Maintaining and repairing the Compact Operating Instructions device ___________________...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Hardware RAID adapter card and hard disks with SAS interface. Observe all safety information in the basic SIMATIC IPC647D and IPC847D Operating Instructions. The information in these Compact Operating Instructions takes precedence over statements in the basic Operating Instructions, the release notes, and online help.
  • Page 4 Preface SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 5: Table Of Contents

    Technical specifications ........................35 General specifications......................35 Power requirements of components (maximum values) ............36 Technical support ..........................37 Service and support ........................ 37 Troubleshooting ........................38 RAID troubleshooting ......................38 Index..............................39 SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 6 Table of contents SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 7: Overview

    Product description SIMATIC IPC with Hardware RAID For the D series of the SIMATIC IPC647D/847D, a new Hardware RAID adapter card has been introduced in connection with SAS hard disks. The new features and modifications of a device that is equipped with Hardware RAID adapter card and SAS hard disks are listed below: ●...
  • Page 8: Scope Of Application

    The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses. In addition to the industrial applications, therefore, it can also be used in building automation or in public facilities. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 9: Highlights

    For automatic data mirroring on two hard disks. Configurations with hot-spare drive available for order. ● RAID5 (striping with parity): For increased memory capacity and improved data security on three hard disks. Configurations with hot-spare drive available for order. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 10: Features

    RAID1 * • 1000 GB (2 × 1000 GB, SAS) RAID5 * • 2000 GB (3 × 1000 GB, SAS) * Additional hot-spare drive can be ordered as an option SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 11: Status Displays Of An Ipc With Hardware Raid Adapter Card

    The HDD | HDD3 ALARM LED does not indicate hard disk activity for Hardware RAID. The Hard- ware RAID hard disk activity is indicated via the LEDs of the removable drive bay. A hot-spare drive of a RAID system is not displayed. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 12 Overview 1.2 Status displays of an IPC with Hardware RAID adapter card SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 13: Safety Information

    ● The connected or built-in peripherals should not introduce a counter emf in excess of 0.5 V into the device. See also General specifications (Page 35) SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 14: Access Protection

    • If the device has a on/off button, assign the parameters of the function of the on/off button to meet your requirements under Windows. You can find the settings in the "Power Options" menu. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 15: Commissioning The Device

    ● The RAID controller with PCIe x8 interface occupies one PCIe x16 expansion slot of the device. The adjacent slot must remain free, and a perforated slot bracket must be mounted to ensure cooling. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 16: Sas Hardware Raid System

    An optionally available hot-spare drive (only for IPC847D) can further increase the availability of the system. ① Connection for the SAS data cable ② Connection for Zero Maintenance Module (ZMM) SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 17 Connection for the Hardware RAID adapter card ② Hard disk connections 0-3 (for the removable rack The installed RAID controller for the "Adaptec RAID ASR8405" module is displayed as follows in the BIOS: SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 18 The safe system states RAID Level 1 or 5 are only reached once synchronization has been successfully completed. In addition, system performance may be limited in the case of a manually started Fix & Verify operation until completion of the verify phase. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 19 The defective hard disk is displayed with port number. Note Deviating figures The following figures and notes apply only to the delivery state of the device without any changes or expansions. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 20 ● The hard disk is brand new. ● The hard disk is set up as a global spare drive. ● The hard disk is set up as a specific dedicaded spare drive. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 21: Expanding The Device And Assigning The Device Parameters

    The hard disks mounted in the removable drive bay must not be exposed to mechanical loads during operation (see technical specifications). This limitation does not apply to the use of SSDs. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 22: Retrofitting Instructions For Ipc847D

    The hard disks mounted in the removable drive bay must not be exposed to mechanical loads during operation (see technical specifications). This limitation does not apply to the use of SSDs. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 23: Maintaining And Repairing The Device

    For installation of the Hardware RAID adapter card, you require the following: ● A T10 screwdriver ① ● The Hardware RAID adapter card with connection for the SAS data cable ② connection for the capacitor block of the ZMM SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 24 Capacitor block ② Extension, only needed for IPC847D ① ● An adapter cable for connection of the hard disk drive to the RAID module ② Observe the numbering of the connections SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 25 When you remove or install a charged capacitor block, the components of the RAID adapter card may be damaged, resulting in data loss. Remove or install a capacitor block only in completely discharged condition. The Siemens genuine spare part is supplied with discharged capacitor block.
  • Page 26 Insert the adapter cable at the marked position (viewed from below). Make sure that the connector latch audibly engages. For removal, follow the steps in reverse order. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 27 7. Insert the adapter cable at the marked position. Make sure that the connector latch engages. 8. Connect the adapter cable to the required drives. For removal, follow the steps in reverse order. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 28: Configuring The Raid Adapter Card

    • "Drives Write Cache = Disabled", which means the write cache of the hard disk is switched off. • "Alarm Control = Disabled", which means the acoustic alarm in case of a fault is switched off SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 29: Replacing A Hard Disk

    ● A hard disk of identical capacity. Replace a defective hard disk with a hard disk of the same type and capacity. ● A key for the removable drive bay lock SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 30: Reinstalling The Software

    The following options are available for restoring the delivery state: ● Restore the entire hard disk/SSD with drives C and D ● Restore drive C This means data stored on drive D are retained. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 31 It is identified by a "P" in front of the SATA port number. Example: P5: DV-W28S-A 7. Follow the instructions on the screen. Note All existing data, programs, user settings, authorizations and license keys on the drives are deleted. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 32: Installing Drivers And Software

    ● You can find information about installing SIMATIC software packages in the corresponding documentation. ● You can obtain information about driver updates and installing application programs from the respective manufacturers. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 33: Installing The Raid Controller Software

    A function is available for this in the SIMATIC IPC Image & Partition Creator. For information on SIMATIC IPC Image & Partition Creator, refer to the corresponding product documentation. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 34 Maintaining and repairing the device 5.3 Reinstalling the software SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 35: Technical Specifications

    Hard disk drive 3.5" SAS 6 Gbps, size: 1000 GB NCQ (Native Command Queuing) is supported. Restrictions when HDDs are mounted in removable drive bays: mechanical stress must be safely excluded. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 36: Power Requirements Of Components (Maximum Values)

    Hard disk drives 3 x 3.5" 0.18 A 40.9 W Hard disk drives 4 x 3.5" 0.24 A 54.4 W DVD burner drive 0.05 A 12.7 W Only in the IPC847D SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 37: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 38: Troubleshooting

    Change address in the link to the Adaptec Storage ager software cannot be Manager software to "localhost". Requirement: The started certificate is stored in the "Trusted Root Certifica- tion Authorities" certificate store and is not expired. SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 39: Index

    RAID1, 9 RAID5, 9 Recovery DVD, 30 Removable hard disk, 29 Restore DVD, 30 Restoring the factory state, 31 SAS, 16 SAS hardware RAID system, 16 SAS RAID system, 16 SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...
  • Page 40 Index SIMATIC IPC647D/847D Hardware RAID Configuration Compact Operating Instructions, 08/2014, A5E34655907-AA...

This manual is also suitable for:

Simatic ipc847d

Table of Contents