CHAPTER 1 GENERAL ADJUSTMENTS SAFETY INSTRUCTIONS WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAU- TION” AND “PRODUCT SAFETY NOTICE” INSTRUCTIONS BELOW. X-RAY RADIATION PRECAUTION 1. Excessive high voltage can produce potentially hazard- 2. The only source of X-RAY RADIATION in this TV receiver ous X-RAY RADIATION.
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAU- TION” AND “PRODUCT SAFETY NOTICE” ON PAGE 3 OF THIS MANUAL. SET-UP ADJUSTMENT The following adjustments should be made when a complete realignment is required or a new picture tube is installed. Perform the adjustments in order as follows : 1.
Page 5
CONVERGENCE ADJUSTMENTS CIRCUMFERENCE CONVERGENCE ADJUSTMENT NOTE: Before attempting any convergence adjustments, the 1. Loosen the clamping screw of deflection yoke slightly to receiver should be operated for at least fifteen min- allow the yoke to tilt. utes. 2. Temporarily put a wedge as shown in figure 1. (Do not remove cover paper on adhesive part of the wedge.) CENTER CONVERGENCE ADJUSTMENT 3.
SERVICE MODE 1. ENTERING TO SERVICE MODE 1) Press o button once on 2) Press o button again to 3) While pressing the o button, Remote Control. keep pressing. press MENU button on TV set. Item Data (Service mode display) 2.
Page 7
4. SELECTING THE ADJUSTING ITEMS 1) Every pressing of CHANNEL s button in the service mode changes the adjustment items in the order of table-2. (t button for reverse order) Refer to table-2 for preset data of adjustment mode. (See SETTING & ADJUSTING DATA on page 13) 5.
Page 8
8. SELF DIAGNOSTIC FUNCTION 1) Press “9” button on Remote Control during display of adjustment menu in the service mode. The diagnosis will begin to check if interface among IC’s are executed properly. 2) During diagnosis, the following displays are shown. Indicated color of mode now selected : Green and Red Indicated color of other modes : White...
DESIGN MODE 1. ENTERING TO DESIGN MODE 2) While pressing (or CALL) button on 3) Press MENU button on TV. 1) Select the Service mode. Remote and press MENU button on TV. ITEM Press DATA Press (Design mode) (Adjustment mode) When QA02 is initialized, items “OPT0”...
ELECTRICAL ADJUSTMENTS ITEM ADJUSTMENT PROCEDURE FOCUS VR ADJ 1. Enter the service mode, then select any register item. 2. Press the TV/VIDEO button on the Remote until the black cross-bar pattern ap- pears on the screen. 3. Adjust the FOCUS control (on T461) for well defined scanning lines on the picture screen.
Page 11
ITEM ADJUSTMENT PROCEDURE WHITE BALANCE 1. Set Contrast to 40, and brightness to +20 by picture control. ADJUSTMENT 2. Set the TV in service mode, and get the inside W/B adjusting signal with VIDEO button. • CUTOFF ADJUSTMENT 3. Select RCUT, GCUT and BCUT with CHANNEL s, t buttons, to set individual (RCUT) values to Initial reference data, and to set GDRV and BDRV to Initial reference (GCUT)
CIRCUIT CHECK HIGH VOLTAGE CHECK CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below. 1. Connect an accurate high voltage meter to the second anode of the picture tube. 2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST controls to minimum (zero beam current). 3.
CHAPTER 2 SPECIFIC INFORMATIONS SETTING & ADJUSTING DATA SAFETY INSTRUCTIONS 29" HIGH VOLTAGE AT ZERO BEAM: 32.8 kV MAX HIGH VOLTAGE: 33.0 kV AC VOLTAGE 110~240 V Table-1 SERVICE MODE ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE: Item Adjustment Reference data RCUT R CUTOFF (B/W)
LOCATION OF CONTROLS Front Behind the door r ON-timer (green) q Power (red) indicator L/MONO R VIDEO AUDIO MENU – ; + Remote sensor MENU Volume down/up Headphone jack t c s a(3) Video 3 input terminal q POWER switch a TV/VIDEO (ø3.5 mm) (Channel select)
Page 15
Remote CALL Power ON/OFF on-screen on/off TXT/TV Mute Direct Select -/– Digit Select TV/VIDEO Select Volume down/up CH down/up Menu –/+ Menu 8/9 – Picture control MENU Menu open – 15 –...
PROGRAMMING CHANNEL MEMORY • First, use the ASM (Automatic Search Memory) function to preset all the active channels in your area automatically. Then, arrange the preset channels with the MANUAL SEARCH , MFT (Manual Fine Tuning) and SKIP functions so that you can tune into only desired channels. To preset channels (ASM) To preset channels (Manual search) and to skip unnecessary position numbers...
Page 17
• The adjustments below are not necessary under normal conditions. However, in areas of inferior broadcast conditions where adjustment is necessary for a better picutre, adjust the tuning with the MFT (Manual Fine Tuning). The AFT OFF status automatically keeps the condition adjusted with the MFT function.
CHASSIS AND CABINET REPLACEMENT PARTS LIST WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAUTION” AND “PRODUCT SAFETY NOTICE” ON PAGE 3 OF THIS MANUAL. CAUTION: The international hazard symbols “ ” in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.
Page 19
Location Location Parts No. Description Parts No. Description C470 24666470 ELECTORLYTIC, 16V 47UF M 3A C829 24591272 PLASTIC FILM, 50V 2700PF J C472 24539474 PLASTIC FILM, 50V 0.47UF J C831 24794470 ELECTORLYTIC, 16V 47UF M C473 24797010 ELECTROLYTIC, 50V 1UF M C833 24797229 ELECTROLYTIC, 50V 2.2UF M...
Page 20
Location Location Parts No. Description Parts No. Description CT02 24232103 CERAMIC DISC, 50V F 0.01UF Z CV20 24073077 ELECTROLYTIC, 50V 0.1UF M 3A (29VZ6DE/29VZ6DA) CV22 24073077 ELECTROLYTIC, 50V 0.1UF M 3A CT03 24232103 CERAMIC DISC, 50V F 0.01UF Z CV30 24085982 ELECTRORYTIC, NONPOLAR, 50V 0.1UF M (29VZ6DE/29VZ6DA)
SCHEMATIC DIAGRAM MODEL : 29VZ6DE / 29VZ6DA / 29VZ6SH WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. CAUTION: The international hazard symbols "*" in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.