Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2016 A Dell Deployment and Configuration Guide...
Separate variables <ip address> <mask> Audience This switch configuration guide describes a verified configuration following Dell best practices for a PS Series iSCSI SAN and is intended for storage or network administrators and deployment personnel. Switch details The table below provides an overview of the switch configuration.
Cabling diagram The cabling diagram shown in Figure 1 represents the Dell recommend method for deploying your servers and PS Series arrays. Cabling diagram Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...
Dell recommended switch configuration These steps show how to configure two Brocade VDX 6940 switches with a Brocade proprietary LAG interconnect. The switches are interconnected using two 40Gb ports (35 and 36) configured as the LAG links. Note: The configuration steps in this section are only recommended when the switch is used as a dedicated SAN for iSCSI traffic (not shared with any other traffic type).
1 mode active type brocade sw0(conf-if-fo-1/0/35-36)# no cee sw0(conf-if-fo-1/0/35-36)# no lldp disable sw0(conf-if-fo-1/0/35-36)# no shutdown sw0(conf-if-fo-1/0/35-36)# exit Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...
Reminder: Perform this step on the other 4 x 10 edge ports. 2.10 Enable switchport sw0(conf-if-te-1/0/1:1-4)# switchport sw0(conf-if-te-1/0/1:1-4)# switchport mode access Reminder: Perform these steps on the other 4 x 10 edge ports. Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...
This operation will modify your startup configuration. Do you want to continue? [y/n]:y 2.15 Configure additional switch Repeat the commands from sections 2.1 through 2.14 to configure the second switch. Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...
QoS receive buffer. Testing indicated the optimal setting is 3MB for the receive queue. sw0# configure sw0(config)# rbridge-id 1 sw0(config-rbridge-id-1)# qos rcv-queue limit 3000 sw0(config-rbridge-id-1)# end sw0# Note: Repeat the commands to configure the buffer on the second switch. Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...
2 This operation will change the configuration to default and reboot the switch. Do you want to continue? [y/n]:y Note: The switch will reboot. Brocade VDX 6940 Switch Configuration Guide for Dell PS Series SANs | SCG3306...