Procedure for Disassembly and Reassembly

INDOOR UNIT
RAK-18/25/35/50PEC
RAK-25/35/50PECC
RAK-10/14/20PECI

1. Front Panel

Be sure to hold the front panel with both hands to
detach and attach it.
When the front panel is fully opened with both
hands, push the right arm to the inside to
release it, and while closing the front panel
slightly, put it out forward.

2. Front cover

(1)After removing the screw of fix ing the
terminal cover, hold the handle of terminal
cover and remove it.
(2)After removing two screws, pull the center of
the front cover forward and release the claws
3
( )Hold the front cover at both lower sides and
pull them forward to remove.
Screw cover
Screw
Shaft
Hole
Fig. 1
Screw
Terminal
Fig. 2
3. Control P .W.B. and Indicating
P.W.B.
(1)Remove each connector from the lead wire.
(2)Remove the four P.W.B. supports from the
control P.W.B.
(3)Pull the support hook at the upper side of the
indication lamp of the indicating P.W.B. and pull
out the P.W.B. forward.
Support hook
.
cover
Control P.W.B.
Indicating P.W.B.
Fig. 3