Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS
request virtual-chassis vc-port
Syntax
Release Information
Description
Options
Additional Information
Required Privilege
Level
Related
Documentation
List of Sample Output
request virtual-chassis
request virtual-chassis
vc-port set pic-slot 1
vc-port set pic-slot 1
port 0
port 0
request virtual-chassis
vc-port set pic-slot 1
port 1 member 3
request virtual-chassis
vc-port delete pic-slot
1 port 1 member 3
840
request virtual-chassis vc-port set | delete pic-slot pic-slot port port-number
<member member-id>
Command introduced before Junos OS Release 10.2 for J-EX Series switches.
Enable or disable an uplink module port (on an SFP or SFP+ uplink module) or an SFP
network port on a J-EX4200-24F switch as a Virtual Chassis port (VCP).
pic-slot pic-slot
—Number of the PIC slot for the uplink module port or SFP network port
on a J-EX4200-24F switch. Specify
Series switch. Specify
—Number of the uplink module port (
port port-number
J-EX4200-24F switch (
member member-id
—(Optional) Enable or disable the specified VCP on the specified
member of the Virtual Chassis configuration.
If you omit
member member-id
VCP or SFP network port configured as a VCP on the switch where the command is
issued.
system-control
request virtual-chassis vc-port on page 841 (dedicated port)
show virtual-chassis vc-port on page 851
show virtual-chassis vc-port statistics on page 854
clear virtual-chassis vc-port statistics on page 836
Understanding Virtual Chassis Components on page 694
request virtual-chassis vc-port set pic-slot 1 port 0 on page 840
request virtual-chassis vc-port set pic-slot 1 port 1 member 3 on page 840
request virtual-chassis vc-port delete pic-slot 1 port 1 member 3 on page 840
user@host>request virtual-chassis vc-port set pic-slot 1 port 0
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port set pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port delete pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
to represent the uplink module PIC on the J-EX
1
to represent the SFP network port on a J-EX4200-24F switch.
0
to
) that is to be enabled or disabled as a VCP.
0
23
, this command defaults to enabling or disabling the uplink
or
) or SFP network port on a
0
1