OPERATING AND
INSTALLATION
INSTRUCTIONS
Models
185, 265, 335, 405
Swimming Pool and Spa Heaters
181/182, 260/261, 330/331, 400/401
Water Heaters and Boilers
D-2 POWER VENT
(FOR ELECTRONIC IGNITION MODELS ONLY)
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids or other combustible
materials in the vicinity of this or any other appliance. To do so may result in an explosion
or fire.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Refer to the user's information manual
provided with this heater. Installation and service must be performed by a qualified in-
staller, service agency or the gas supplier.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
·
Do not try to light any appliance.
·
Do not touch any electrical switch; do not use any phone in your building.
·
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
·
If you cannot reach your gas supplier, call the fire department.
This manual should be maintained in legible condition and
kept adjacent to the appliance or kept in a safe place for
future reference.
CATALOG NO. 6000.57D
Effective:
10-26-06
Replaces:
03-15-03
P/N 241086 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Raypak 185

  • Page 1 OPERATING AND INSTALLATION INSTRUCTIONS Models 185, 265, 335, 405 Swimming Pool and Spa Heaters 181/182, 260/261, 330/331, 400/401 Water Heaters and Boilers D-2 POWER VENT (FOR ELECTRONIC IGNITION MODELS ONLY) FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance.
  • Page 2: Receiving Equipment

    The Power Vent Assembly is a fan assisted combustion system designed for application to Raypak Pool Heater Models 185-405. The unit, when installed as directed, is capable of operating in applications such as through the wall venting and reduced horizontal and vertical vent pipe sizes in new and existing installations.
  • Page 3: Installation Requirements

    3. INSTALLATION REQUIREMENTS The equipment must be installed in accordance with local codes, or in the absence of local codes with the latest edition of the National Fuel Gas Code, ANSI Z223.1, the National Electrical Code, ANSI/NFPA 70. The equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made.
  • Page 4 MOUNTING POWER VENT ASSEMBLY-(continued 11. Mount the PowerVent assembly bottom on the 6” vent. Twist the assembly downward. Snap the mounting brackets into their appropriate slot to hold the Power Vent in position. Note: While twisting you may notice some roughness, this is due to a tight seal between the 6”...
  • Page 5 VENTING The vent pipe must be the same size or larger than what is indicated. The D-2 Power Vent are capable of 360-degree discharge rotation and operate with a positive vent static pressure and with a vent gas temperature less than 400°F. The total length of horizontal run shall not exceed an equivalent of 40 feet including termination cap.
  • Page 6 The Raypak Power Vent operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent and as such it is listed as a CATEGORY III appliance. Exception: When a Power Vent is connected to a vertical vent of sufficient height to generate a negative draft in the system.
  • Page 7 185-405 POOL HEATER (ATMOSPHERIC)
  • Page 8 185-405 POOL HEATER (Low NOx)
  • Page 9 182-260 WH1 (ATMOSPHERIC)
  • Page 10 181-261 WH1 (Low NOx)
  • Page 11: Sequence Of Operation

    Dimensional Data Model 18.13 12.38 7.88 4.25 18.13 12.38 7.88 4.25 18.13 12.38 7.88 4.25 18.13 12.38 7.88 4.25 18.13 12.38 7.88 4.25 18.13 12.38 7.88 4.25 17.50 15.75 7.63 6.00 17.50 15.75 7.63 6.00 17.50 15.75 7.63 6.00 17.50 15.75 7.63 6.00 17.50 15.75 7.63 6.00 17.50 15.75 7.63 6.00 SEQUENCE OF OPERATION...
  • Page 12: Start-Up Procedures

    START UP PROCEDURES The water system, the gas system and the electrical system for the heater should be completed and checked as per the heater installation manual and associated documents. 1. Turn on power to the heater with the manual main gas valve and pilot gas valve off.
  • Page 13: Illustrated Parts List

    ILLUSTRATED PARTS LIST...
  • Page 14 Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada LTD, 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd, 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.S.A.