hit counter script

Toshiba e-STUDIO2006 Service Manual page 582

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

05/08
Mode
Element
Sub element
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Counter
Maintenance
mode
08
Setting
Counter
Maintenance
mode
08
Setting
Counter
Maintenance
mode
08
Setting
Counter
Maintenance
mode
08
Setting
Counter
Maintenance
mode
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Sub-
Item
Subitem
Code
code
5472
-
Low power
consumption control:
operating time
5497
0
Low power
consumption control:
Lamp maximum ON
time (Center)
5497
1
Low power
consumption control:
Lamp maximum ON
time (Side)
5498
0
Low power
consumption control:
Lamp maximum OFF
time (Center)
5498
1
Low power
consumption control:
Lamp maximum OFF
time (Side)
5554
-
PM counter setting
value for developer
material (K)
5555
-
PM time counter setting
value for developer
material (K)
5562
-
Parts PM counter set
value
5563
-
Parts PM time counter
set value
5568
-
Current value of PM
counter for developer
material (K)
Default
Acceptable
Details
SRAM
value
value
4
0-5
M
10
1-50
M
10
1-50
M
15
1-50
M
15
1-50
M
55000
0-600000
M
115000
0-600000
M
165000
0-600000
M
345000
0-600000
M
0
0-600000
M
14-1-62
Contents
This code is used to set a control time on Low power
consumption control. Use the above default value, unless
otherwise required.
0: 10 seconds after the start / Preformed for 35 seconds
1: 15 seconds after the start / Preformed for 30 seconds
2: 20 seconds after the start / Preformed for 25 seconds
3: 10 seconds after the start / Preformed for 30 seconds
4: 15 seconds after the start / Preformed for 25 seconds
5: 20 seconds after the start / Preformed for 20 seconds
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
Sets the number of printed sheets to display the message
that prompts the PM of developer material.
Sets the accumulated driving time to display the message
that prompts the PM of developer material.
Sets the number of printed sheets to display the message
that prompts the PM of part.
Sets the accumulated driving time to display the message
that prompts the PM of part.
Displays the current number of printed sheets. Counts up
by turning on the registration sensor.
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
20L/
20H/
Proce
23L/
23H/
dure
25L
25H
1
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
1
Y
Y
1
Y
Y
1
Y
Y
1
Y
Y
1
Y
Y

Hide quick links: