Installing the Router Ground Connection

Figure 20: Mounted to wall
NOTE: For hollow-wall mounting, each bracket requires two wall anchors with washers. Wall anchors and
washers must be size number 10.
3. Route the cables so that they do not put a strain on the connectors or mounting hardware. Cables should
be routed down relative to the router to prevent water from traveling on the cables.
Installing the Router Ground Connection
The router must be connected to a reliable earth ground. Install the ground wire in accordance with local
electrical safety standards.
• For NEC-compliant grounding, use size 14 AWG (2 mm2) or larger copper wire and a ring terminal with
• For EN/IEC 60950-compliant grounding, use size 18 AWG (1 mm2) or larger copper wire.
WARNING: This equipment must be grounded. Never defeat the ground conductor or operate the equipment
in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority
or an electrician if you are uncertain that suitable grounding is available. Statement 1024
WARNING: This equipment needs to be grounded. Use a green and yellow 12 to 14 AWG ground wire to
connect the host to earth ground during normal use. Statement 242
To install the ground connection, follow these steps:
Cisco IR829 Industrial Integrated Services Router Hardware Installation Guide
48
an inner diameter of 1/4 in. (5 to 7 mm).