LTE-L57V / LTE-L57C Cellular Communication Modules
Installation Guide
General Information
The LTE-L57V / LTE-L57C Cellular Communication Modules allow the LYNX Touch L5210 and L7000 controls to
communicate with the Central Station via the LTE cellular network.
See LYNX Touch Series Installation and Setup Guide (p/n 800-19974V1 or higher) for additional installation and
programming information.
Installing the Communication Module in the LYNX Touch Series Control
1. Install the provided FCC label (LTE-L57V: 800-23737
or LTE-L57C: 800-23737-1) on the control's case
back (see diagram).
2. Release the LYNX Touch front case from the back
case by depressing the two locking tabs at the top of
the unit with the blade of a medium size screwdriver
(see diagram below).
3. Install the communication module into the LYNX
Touch control front case as shown. Ensure that the
connector board is properly seated into the
receptacle on the control.
4. Secure the module with the three provided screws.
5. Enable the communication module, configure alarm
reporting and module supervision and register the
device. Refer to the "Program the Radio" and
"Diagnostics" sections in the LYNX Touch Series
Installation & Setup Guide
Installing the LTE-L57 Communication Module in the LYNX Touch (L5210 Shown)
Ê800-23726HŠ
800-23726 10/17 Rev B
(p/n 800-19974V1 or higher
).
Typical FCC/IC Label Location (L5210 shown)
Initial Power Up Note
Upon initial communicator
power up, a network
initialization sequence
begins and the LYNX control
displays the following:
SIM not yet provisioned.
Please wait. WARNING –
Do not reset the panel!!!
This sequence may take up
to 15 minutes. Do not reset
power during this
initialization time. After the
communicator has
completed network
initialization, subsequent
resets or power ups can take
up to 90 seconds.