hit counter script
Siemens Sinamics G130 Basic Operator Panel 20 Operating Instructions Manual
Siemens Sinamics G130 Basic Operator Panel 20 Operating Instructions Manual

Siemens Sinamics G130 Basic Operator Panel 20 Operating Instructions Manual

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Sinamics G130 Basic Operator Panel 20

  • Page 3 ___________________ Safety information ___________________ General ___________________ SINAMICS Installation ___________________ Setting parameters with the BOP20 SINAMICS G130 Basic Operator Panel 20 (BOP20) ___________________ Technical specifications Operating Instructions Firmware version V5.1 11/2017 A5E00809375A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information ........................... 5 General safety instructions ....................... 5 Handling electrostatic sensitive devices (ESD) ..............10 Industrial security ........................11 General ..............................13 Installation ............................15 Removal ..........................17 Setting parameters with the BOP20....................... 19 BOP20 overview ........................19 Displays/indicators and using the BOP20 ................
  • Page 6 Table of contents Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 7: Safety Information

    Safety information General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or serious injury. • Only work on electrical equipment if you are appropriately qualified. • Always observe the country-specific safety rules for all work. Generally, the following steps apply when establishing safety: 1.
  • Page 8 Safety information 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. •...
  • Page 9 • If you come closer than around 2 m to such components, switch off any radio devices or mobile phones. • Use the "SIEMENS Industry Online Support App" only on equipment that has already been switched off. WARNING Motor fire in the event of insulation overload There is a greater load on the motor insulation as result of a ground fault in an IT system.
  • Page 10 Safety information 1.1 General safety instructions WARNING Fire due to inadequate ventilation clearances Inadequate ventilation clearances can cause overheating of components with subsequent fire and smoke. This can cause severe injury or even death. This can also result in increased downtime and reduced service lives for devices/systems. •...
  • Page 11 Safety information 1.1 General safety instructions Note Important safety instructions for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety instructions in the Safety Integrated manuals. Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 12: Handling Electrostatic Sensitive Devices (Esd)

    Safety information 1.2 Handling electrostatic sensitive devices (ESD) Handling electrostatic sensitive devices (ESD) Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Damage through electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual components, integrated circuits, modules or devices.
  • Page 13: Industrial Security

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.
  • Page 14 Safety information 1.3 Industrial security Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 15: General

    General Description The BOP20 Basic Operator Panel is a basic operator panel with six keys and a backlit display unit. The BOP20 can be plugged onto the SINAMICS Control Unit and operated. The BOP20 supports the following functions: ● Entering parameters and activating functions ●...
  • Page 16 General Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 17: Installation

    Installation The following photos and captions explain how to assemble the Basic Operator Panel 20 (BOP20) on the Control Unit. NOTICE Damage to the interface for the BOP20 at the Control Unit through tilting If the BOP20 is skewed when inserting or withdrawing it, this can damage the interface for the BOP20.
  • Page 18 Installation 3. Press the latching cams on the BOP20 togeth- CU320-2 DP with BOP20 installed er, and push the BOP20 straight in until you hear it latch into position. Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 19: Removal

    Installation 3.1 Removal Removal Please note the following information when removing the BOP20 from the Control Unit: 1. Simultaneously press the latching cams on the BOP20. 2. Always withdraw the BOP20 straight out (without skewing it). Never withdraw the BOP20 by pulling it at its lower edge, as this could damage the interface at the rear.
  • Page 20 Installation 3.1 Removal Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 21: Setting Parameters With The Bop20

    Setting parameters with the BOP20 BOP20 overview Overview of displays and keys Figure 4-1 Overview of displays and keys Information on the displays Table 4- 1 Displays/indicators Display Meaning Top left, 2 chars. The active drive object of the BOP is displayed here. The displays and key operations always refer to this drive object.
  • Page 22 Setting parameters with the BOP20 4.1 BOP20 overview Information on the keys Table 4- 2 Keys Name Meaning Switches on the drives for which the command "ON/OFF1" is to be issued from the BOP. Binector output r0019.0 is set using this key. Switches off the drives for which the commands "ON/OFF1", "OFF2", and "OFF3"...
  • Page 23 Setting parameters with the BOP20 4.1 BOP20 overview BOP20 functions Name Meaning Backlighting The backlighting can be set using p0007 in such a way that it switches itself off automatical- ly after the set time if no actions are carried out. Changeover active drive From the point of view of the BOP, the active drive is defined using p0008 or using the "Fn"...
  • Page 24 Setting parameters with the BOP20 4.2 Displays/indicators and using the BOP20 Parameters All drive objects BOP status display selection • p0005 BOP status display mode • p0006 BOP user-defined list • p0013 Save drive object parameters • p0971 Drive object, Control Unit BOP status display •...
  • Page 25: Displays/Indicators And Using The Bop20

    Setting parameters with the BOP20 4.2 Displays/indicators and using the BOP20 Displays/indicators and using the BOP20 Status display The status display for each drive object can be set using p0005 and p0006. Using the status display, you can switch to the parameter display or to a different drive object. The following functions are supported: ●...
  • Page 26 Setting parameters with the BOP20 4.2 Displays/indicators and using the BOP20 Parameter display The parameters are selected in the BOP20 using the number. To call up the parameter display from the status display, press the "P" key. You can search for the parameters you require using the arrow keys.
  • Page 27 Setting parameters with the BOP20 4.2 Displays/indicators and using the BOP20 Value display To switch from the parameter display to the value display, press the "P" key. In the value display, the values of the setting parameters can be increased and decreased using the arrow keys.
  • Page 28 Setting parameters with the BOP20 4.2 Displays/indicators and using the BOP20 Examples Example 1: Changing a parameter Prerequisite: The appropriate access level is set (for this particular example, p0003 = 3). Figure 4-4 Example: Change p0013[4] from "0000" to "0300". Example 2: Changing binector and connector input parameters Binector output r0019.0 of the Control Unit (drive object 1) is connected to binector input p0840[0] (OFF1) of drive object 2.
  • Page 29: Fault And Alarm Displays

    Setting parameters with the BOP20 4.3 Fault and alarm displays Fault and alarm displays Displaying faults Figure 4-6 Displaying faults Displaying alarms Figure 4-7 Displaying alarms Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 30: Controlling The Drive Using The Bop20

    Setting parameters with the BOP20 4.4 Controlling the drive using the BOP20 Controlling the drive using the BOP20 Description When the drive is commissioned, it can be controlled via the BOP20. A control word is available on the Control Unit drive object (r0019) for this purpose, which can be interconnected with the appropriate binector inputs of the drive.
  • Page 31 Setting parameters with the BOP20 4.5 Important functions via BOP20 Restore the factory settings The factory setting of the complete device can be restored in the CU drive object. ● p0009 = 30 ● p0976 = 1 Copy from RAM to ROM You can initiate the saving of all parameters to the non-volatile memory (memory card) in the drive object CU: ●...
  • Page 32 Setting parameters with the BOP20 4.5 Important functions via BOP20 Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...
  • Page 33: Technical Specifications

    Technical specifications Table 5- 1 Technical specifications Basic Operator Panel 20 (BOP20) Electronics power supply 3.3 V DC (provided by CU320) Weight 0.02 kg Basic Operator Panel 20 (BOP20) Operating Instructions, 11/2017, A5E00809375A...

This manual is also suitable for:

Sinamics g130 bop20

Table of Contents