SWITCH
SWITCH
NAME
LOCATION
SW5
Parts
Mounted
Face
Page 9
Table 1 ISDN PRI Switch Descriptions (Continued)
KIND OF SWITCH
Dip Switch
ON
1 2 3 4 5 6 7 8
(Standard Setting)
NEAX2400 ICS ISDN PRI Installation Notes
SWITCH
SWITCH
NO.
SETTING
1 ~ 3
PAD Pattern Selection
SW5-1 SW5-2 SW5-3
4, 5
PAD Control
SW5-4 SW5-6
6, 7
Data PAD Control
SW5-6 SW5-7
ON
Idle code sending: To be
sent out
8
OFF
Idle code sending: Not to
be sent out
MEANING
PAD
Pattern
ON
OFF
ON
PAD
Pattern
1
OFF
OFF
ON
PAD
Pattern
2
A →µ
ON
ON
OFF
Loss/
Bothway
A →µ
OFF
ON
OFF
Loss/
Receive
µ→ A
ON
OFF
OFF
Loss/
Bothway
µ→ A
OFF
OFF
OFF
Loss/
Receive
Other Combinations
Not
possible
PAD Control
ON
ON
Bothway
Send only
OFF
ON
(Receive 0dB)
ON
OFF
Receive only
(send 0dB)
Fixed to ARTD
OFF
OFF
command
Data PAD Value
ON
ON
64Kbps
OFF
ON
64Kbps INV
ON
OFF
56Kbps AT&T
48Kbps
OFF
OFF
PROTIMS
ETI-152A