S485 cable installation:
The connection of the RS485 serial communication cable must be made to
the specific RS485 connector
as follows:
1a. Install the cable on the RS485 connector on the inverter.
1b. Slide the corresponding part on the cable until bringing it snug to the
RS485 connector of the inverter. Insertion of the corresponding part is
guided by reference points which enable its correct positioning.
2a. Turn the fastening ring nut until blocking the two connectors and
check the correctness of the installation.
2b. Turn the holding ring nut to a tightening torque of 0.6-0.8Nm
1
2
Скачано с сайта интернет магазина https://axiomplus.com.ua/
present on the lower side of the inverter
14
Click
1a
2a
2b
- 62 -
5 - Installation
1b
0.6÷0.8Nm