hit counter script

Fm And Csa Connection Drawings; Instructions Specific To Hazardous Area Installations (Reference European Atex Directive 2014/34/Eu Annex Ii, 1/0/6) - Siemens SITRANS L Series Compact Operating Instructions

Hide thumbs Also See for SITRANS L Series:
Table of Contents

Advertisement

Device nameplate (ATEX/IECEX/INMETRO/RMC)
The ATEX certificate can be downloaded from the product page of our website at:
www.siemens.com\probelr (www.siemens.com/SitransProbeLR).
Go to Support > Approvals / Certificates.
The IECEx certificate listed on the nameplate can be viewed on the IECEx website. Go
to:http://iecex.iec.ch (http://iecex.iec.ch) and click on Ex Equipment Certificates of Conformity
then enter the certificate number IECEx SIR 13.0005X.
5.4

FM and CSA connection drawings

The FM Intrinsically Safe connection drawing (A5E01003040) listed on the device nameplate
can be downloaded from our website:
Product page (www.siemens.com/SitransProbeLR)
Go to Technical Info > Images, graphics, drawings.
The CSA Intrinsically Safe connection drawing (A5E01003039) listed on the device
nameplate can be downloaded from our website:
Product page (www.siemens.com/SitransProbeLR)
Go to Technical Info > Images, graphics, drawings.
5.5
Instructions specific to hazardous area installations (reference
European ATEX Directive 2014/34/EU Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number SIRA
06ATEX2354X:
1. For use and assembly, refer to the main instructions.
2. The equipment is certified for use as Category 1G equipment.
3. The equipment may be used with flammable gases and vapors with apparatus group IIC
and temperature class T4.
4. The equipment is certified for use in an ambient temperature range of –40 °C to 80 °C.
5. The equipment has not been assessed as a safety related device (as referred to by
Directive 2014/34/EU Annex II, clause 1.5).
6. Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 60079-14 and EN
60079-17 in Europe).
7. Repair of this equipment shall be carried out by suitably trained personnel in accordance
with the applicable code of practice (e.g. EN 60079-19 within Europe).
8. Components to be incorporated into or used as replacements in the equipment shall be
fitted by suitably trained personnel in accordance with the manufacturer's documentation.
SITRANS Probe LR with mA/HART
Compact Operating Instructions, 05/2019, A5E46248119-AC
5.4 FM and CSA connection drawings
Connecting
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans probe lr with ma/hart

Table of Contents