RECOMMENDATIONS AND SUGGESTIONS INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 650 mm. Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
INSTALLATION Drilling the Support surface and Fitting the Hood • The Hood can be fitted directly on the lower surface of the Wall Units (650 mm min. above the Cooker Top) using the snap- on Side Supports. • Make an opening on the lower surface of the Wall Unit, as indicated.
Page 6
ø 120 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to the installer. • Install the Flange ø 150 mm 9. •...
By pulling out the sliding panel it is possible to automatically activate all the hood functions. By simply closing the sliding panel all the functions are switched off. SWITCH FUNCTIONS Light Switches the lighting system on and off Motor Switches the extractor motor on and off 1.
MAINTENANCE Grease filters CLEANING METAL CASSETTE GREASE FILTERS • The filters must be cleaned every 2 months, or more frequently in case of particularly heavy use of the hood. Filters can be washed in a dishwasher. • Pull out the sliding suction panel. •...