hit counter script

ZIEHL MU1001K Operating Manual

Measuring-transducer

Advertisement

Quick Links

Temperature Relays and MINIKA®
Operating Manual MU1001K
- Measuring-Transducer
MU1001K
12370-0707-01
Mains Monitoring
Digital Panelmeters MINIPAN®
Switching Relays and Controls
Seite 1 / 12
ZIEHL industrie – elektronik GmbH + Co KG
Daimlerstraße 13, D – 74523 Schwäbisch Hall
+ 49 791 504-0, info@ziehl.de, www.ziehl.de
Measuring Transducers
Grid- and Plant Protection
updated: 2018-11-12 / sm
from Firmware: 0-04
www.ziehl.de

Advertisement

Table of Contents
loading

Summary of Contents for ZIEHL MU1001K

  • Page 1 ZIEHL industrie – elektronik GmbH + Co KG Daimlerstraße 13, D – 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA® Mains Monitoring Digital Panelmeters MINIPAN® Switching Relays and Controls Measuring Transducers Grid- and Plant Protection...
  • Page 2: Table Of Contents

    Factory setting ..........................10 Query of firmware-version ......................10 6.9.1 Revision Firmware ........................ 10 Maintenance and repair ........................10 Error search ............................10 Technical data ............................11 10 Housing Type K ............................ 12 MU1001K 12370-0707-01 Seite 2 / 12 www.ziehl.de...
  • Page 3: Application And Short Description

    1 Application and short description Universal Measuring-Transducers MU1001K can measure DC-signals up to 300 V. Pre-set measuring-ranges can be selected by the user. More measuring-ranges (zero and full scale) can be easily scaled. The output-signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring-input and supply-voltage.
  • Page 4: Important Information

    The device have a universal power supply, that is suitable for DC- and AC-voltages. Before connecting the device to supply-voltage make sure that the connected voltage corresponds with the voltage on the lateral type on the device MU1001K 12370-0707-01 Seite 4 / 12...
  • Page 5: Commissioning

    All wires connected to the device must have insulation rated at least 300 Vac. 6 Commissioning 6.1 Overview of commissioning The MU1001K can be commissioned to predefined standard ranges or scaled to an arbitrary range. There are two different ways to do the settings: Point 6.2 – 6.4: MU1001K setting a predefined range Point 6.5 –...
  • Page 6: Setting A Predefined Range

    • When scaling is started, all parameters are reset to default. Parameters cannot be checked after scaling has been finished. • In normal operating mode the selected input is displayed with LED. MU1001K 12370-0707-01 Seite 6 / 12 www.ziehl.de...
  • Page 7: Diagram For Setting A Predefined Range

    6.4 Diagram for setting a predefined range Mode Normal state MU1001K 12370-0707-01 Seite 7 / 12 www.ziehl.de...
  • Page 8: Overview Of Scaling An Arbitrary Range

    • When scaling is started, all parameters are reset to default. Parameters cannot be checked after scaling has been finished. • In normal operating mode the selected input is displayed with LED. MU1001K 12370-0707-01 Seite 8 / 12 www.ziehl.de...
  • Page 9: Diagram For Scaling Of Range

    6.7 Diagram for scaling of range Mode Normal state Signal input = Zero point Signal input = Full scale MU1001K 12370-0707-01 Seite 9 / 12 www.ziehl.de...
  • Page 10: Factory Setting

    6.9.1 Revision Firmware Version 0-04: • additional predefined standard ranges (-10…10V, -60…60mV, -150…150mV, -300…300mV) 7 Maintenance and repair ZIEHL industrie-elektronik GmbH + Co KG Daimlerstr.13 D-74523 Schwaebisch Hall Phone: +49 791 504-0 Fax: +49 791 504-56 E-Mail: info@ziehl.de Homepage: www.ziehl.com...
  • Page 11: Technical Data

    Overvoltage category II reinforced insulation Rated insulation voltage Ui 300 V EMC-tests EN 61326-1 Equipment intended for use in industrial locations Emission EN 61326-1, CISPR 11 class B Immunity EN 61326-1 industrial environment MU1001K 12370-0707-01 Seite 11 / 12 www.ziehl.de...
  • Page 12: Housing Type K

    Snap mounting on 35 mm standard rail EN 60 715 or M4 screws Weight app. 100 g Subject to technical changes 10 Housing Type K Dimensions in mm 22,5 110,0 100,5 lower part upper part screw holes for screw-mount MU1001K 12370-0707-01 Seite 12 / 12 www.ziehl.de...