Installation
Read completely, then follow step by step.
Selection of the best location
• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in front of the unit.
• Make sure that condensation drainage can be conveniently routed away.
Do not install near a doorway.
• Ensure that the space around the left and right of the unit is more than 50cm. The unit should be installed as high on the
wall as possible, allowing a minimum of 10cm from ceiling.
• Use a stud finder to locate studs to prevent unnecessary damage to the wall.
CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.
Features
Signal Receptor
Front Panel
Air Discharge
More
than 500mm
More than 1.5m
More than 200mm(Minimum)
More
than 500mm
Air Filter
Plasma Filter
Installation