SINUMERIK
SINUMERIK ONE
PPU 1740
Equipment Manual
Valid for:
SINUMERIK ONE PPU 1740 - 1500
SINUMERIK ONE PPU 1740 - 1900
01/2019
A5E47615272B AA
Preface
Fundamental safety
instructions
System overview
System characteristics
Application planning
Installing
Service and maintenance
Interface description
Connectable components
Technical data
Spare parts and accessories
Appendix
1
2
3
4
5
6
7
8
9
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINUMERIK ONE PPU 1740 Series

  • Page 1 Preface Fundamental safety instructions System overview SINUMERIK System characteristics SINUMERIK ONE PPU 1740 Application planning Installing Equipment Manual Service and maintenance Interface description Connectable components Technical data Spare parts and accessories Appendix Valid for: SINUMERIK ONE PPU 1740 - 1500 SINUMERIK ONE PPU 1740 - 1900 01/2019 A5E47615272B AA...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Siemens' content, and adapt it for your own machine documentation. Training At the following address (http://www.siemens.com/sitrain), you can find information about SITRAIN (Siemens training on products, systems and solutions for automation and drives). FAQs You can find Frequently Asked Questions in the Service&Support pages under Product Support (https://support.industry.siemens.com/cs/de/en/ps/faq).
  • Page 4 Note regarding the General Data Protection Regulation Siemens observes standard data protection principles, in particular the principle of privacy by design. That means that this product does not process / store any personal data, only technical functional data (e.g. time stamps). If a user links this data with other data (e.g. a shift schedule) or stores personal data on the same storage medium (e.g.
  • Page 5: Table Of Contents

    Table of contents Preface .................................3 Fundamental safety instructions........................7 General safety instructions.......................7 Equipment damage due to electric fields or electrostatic discharge ........11 Warranty and liability for application examples ..............12 Industrial security ........................13 Residual risks of power drive systems ...................15 System overview ............................17 Application..........................17 System configuration......................19 System characteristics..........................23...
  • Page 6 Table of contents Installing the PPU........................56 Position of mounting clips for IP65 installation...............59 Service and maintenance ...........................61 Interface description ...........................63 Interface overview ........................63 Power supply connection .......................65 7.2.1 Requirements for the power supply ..................65 7.2.2 Connecting the power supply....................66 Ethernet..........................67 Digital inputs/outputs......................71 7.4.1 Technical data ........................75...
  • Page 7: Fundamental Safety Instructions

    Fundamental safety instructions General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or severe injury. ● Only work on electrical devices when you are qualified for this job. ●...
  • Page 8 Fundamental safety instructions 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury.
  • Page 9 ● If you come closer than around 2 m to such components, switch off any radios or mobile phones. ● Use the "SIEMENS Industry Online Support app" only on equipment that has already been switched off. WARNING...
  • Page 10 Fundamental safety instructions 1.1 General safety instructions Note Important safety notices for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety notices in the Safety Integrated manuals. PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 11: Equipment Damage Due To Electric Fields Or Electrostatic Discharge

    Fundamental safety instructions 1.2 Equipment damage due to electric fields or electrostatic discharge Equipment damage due to electric fields or electrostatic discharge Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Equipment damage due to electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual...
  • Page 12: Warranty And Liability For Application Examples

    Fundamental safety instructions 1.3 Warranty and liability for application examples Warranty and liability for application examples Application examples are not binding and do not claim to be complete regarding configuration, equipment or any eventuality which may arise. Application examples do not represent specific customer solutions, but are only intended to provide support for typical tasks.
  • Page 13: Industrial Security

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Products and solutions from Siemens constitute one element of such a concept.
  • Page 14 Fundamental safety instructions 1.4 Industrial security WARNING Unsafe operating states resulting from software manipulation Software manipulations, e.g. viruses, Trojans, or worms, can cause unsafe operating states in your system that may lead to death, serious injury, and property damage. ● Keep the software up to date. ●...
  • Page 15: Residual Risks Of Power Drive Systems

    Fundamental safety instructions 1.5 Residual risks of power drive systems Residual risks of power drive systems When assessing the machine- or system-related risk in accordance with the respective local regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer must take into account the following residual risks emanating from the control and drive components of a drive system: 1.
  • Page 16 Fundamental safety instructions 1.5 Residual risks of power drive systems PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 17: System Overview

    System overview Application SINUMERIK ONE is available in the following PPU hardware versions: ● SINUMERIK ONE PPU 1740-1500 ● SINUMERIK ONE PPU 1740-1900. Overview SINUMERIK ONE offers modularity, openness, flexibility, and uniform structures for operation, programming and visualization. It provides a system platform with trend-setting functions for almost all technologies.
  • Page 18 System overview 2.1 Application Fields of application The SINUMERIK ONE can be used worldwide for turning, drilling, milling, grinding, laser machining, nibbling, punching, in tool and mold making, for high-speed cutting applications, for wood and glass processing, for handling operations, in transfer lines and rotary indexing machines, for mass production and Job Shop production.
  • Page 19: System Configuration

    System overview 2.2 System configuration System configuration The SINUMERIK ONE combines CNC, HMI, PLC, closed-loop control and communication tasks within a single PPU. Components For operation, programming, and visualization purposes, the corresponding operating software is already integrated into the CNC software for the PPU and therefore runs on the high- performance PPU module.
  • Page 20 System overview 2.2 System configuration Figure 2-1 Topology example 1 Figure 2-2 Topology example 2 PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 21 System overview 2.2 System configuration SINAMICS S120 drive system Only the SINAMICS S120 Line Modules and Motor Modules are used for drive control. Motor Modules can be used to connect servomotors as type 1FK7, 1FT7, and 1PH8 feed and main spindle motors.
  • Page 22 System overview 2.2 System configuration PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 23: System Characteristics

    System characteristics PPU versions The scalability of the hardware and software – both from a CNC perspective and in terms of operation, the SINUMERIK ONE can be used in many sectors. The possibilities range from simple positioning tasks up to complex multi-axis systems. Charcteristics of PPU The following are the key characteristics of PPU 1740: ●...
  • Page 24 System characteristics 3.1 PPU versions Rear of the PPU 1740 Figure 3-2 PPU 1740 connections (rear) Figure 3-3 PPU 1740 connections (side view) X160 / P1 Profinet X150 / P1R, P2R Two Profinet ports X100... X103 DriveCliQ X122,X132: Drive Digital IO (isolated) X242, X252: NC PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 25 System characteristics 3.1 PPU versions PE connection using 5mm cable lug, mounted using an M5 nut (pre-installed). Tightening torque 3.0 Nm. X143 Handwheel inputs 24V supply (4pin) X127 / P1 X125 Front-USB 3.0 PLC mode selector switch NCK commissioning switch LED display 7-segment display X120, X130...
  • Page 26 System characteristics 3.1 PPU versions PPU1740 -1900 Temperature 0 to 40 °C (front) 0 to 45 °C (rear) Air Ventilation passive cooling without fan Display/Front Touch sensor with Coverglass Display/Touch Multitouch Resolution 1920x1080 Type plate The PPU type plate is located on the rear. All the information required to clearly identify the PPU is available on the type plate.
  • Page 27: Operator Controls And Display Elements

    System characteristics 3.2 Operator controls and display elements Operator controls and display elements 3.2.1 Overview of operating and display elements Only appropriately trained personnel may use the operating elements provided in the service area. NOTICE Electrostatic discharge if there is no ground connection If there is no ground connection or a faulty ground connection, then the electronic components in the devices can be damaged as a result of electrostatic discharge (ESD).
  • Page 28: Led Display

    System characteristics 3.2 Operator controls and display elements 3.2.2 LED display Figure 3-6 LED display Meaning of the RUN/STOP, ERROR and MAINT PLC-LEDs RUN/STOP LED ERROR LED MAINT LED Meaning Supply voltage at the CPU not present or too low. LED off LED off LED off...
  • Page 29 System characteristics 3.2 Operator controls and display elements RUN/STOP LED ERROR LED MAINT LED Meaning CPU performs internal activities during STOP, e.g. ramp-up after STOP. LED off LED off LED flashes yellow Downloading the user program from the SIMATIC Memory Card Startup (transition from RUN →...
  • Page 30 System characteristics 3.2 Operator controls and display elements Name Function Status Meaning Communi‐ CP not ramped up / started cation LED off Communication via CP possible (RUN operating state) LED lights up green Communication possible (no configuration) LED flashes green CP was stopped via PLC/TIA.
  • Page 31: 7-Segment Display

    System characteristics 3.2 Operator controls and display elements 3.2.3 7-segment display Figure 3-7 7-segment display Displaying messages ● It serves to output status information during commissioning, ramp-up and cyclical operation. The 7-segment display is visible on the rear side of the PPU. ●...
  • Page 32: Diag\Reset Button

    System characteristics 3.2 Operator controls and display elements NCK outputs 7-segment display Meaning Not applicable. Not applicable. Debugger was initialized. NCK operating system was successfully activated. NCK operating system has booted, initial task is being processed (→ the application boots). Initialization was successfully performed;...
  • Page 33: Start-Up And Mode Selector Switch

    System characteristics 3.2 Operator controls and display elements Performing the operation DIAG/RESET button has two functions: ● RESET: Press the button for more than 10 seconds to restart the PPU. ● DIAG: Press the button for less than 8 seconds to start the DiDac function. This function collects all the available log files of the operating software and stores them in the following directory: /card/user/sinumerik/didac/out_<Date-Time>.7z.
  • Page 34: Operation When Wearing Gloves

    System characteristics 3.2 Operator controls and display elements 3.2.6 Operation when wearing gloves Recommended gloves The following gloves are recommended when using the PPU 1740: ● BM Polyco: Reusable gloves, white, cotton Article number: RS 562-952) ● Carex (leather) (Article number: 1505/k) ●...
  • Page 35: Operating With Gestures

    System characteristics 3.2 Operator controls and display elements 3.2.7 Operating with gestures Finger gestures to operate the touch display ● Select window ● Select an object ● Activate entry field Tapping and holding ● Open object to be changed Vertical swipe with 1 finger (flick) ●...
  • Page 36 System characteristics 3.2 Operator controls and display elements Pan with 1 finger ● Moving content of graphics ● Moving content of lists Pan with 2 fingers ● Rotating content of graphics Tap with 2 fingers ● Calling a context menu Spread ●...
  • Page 37: Memory Card Interface

    System characteristics 3.3 Memory card interface Memory card interface 3.3.1 SD card system Overview PPU1740 has an SD card interface provided on the backside of the panel. It is necessary to run the PPU. SD card with system software The SD card is not supplied along with the PPU. It must be ordered as a separate component. NOTICE Inserting or withdrawing with the power connected can destroy the SD card The SD card may be inserted or removed only when the system is de-energized.
  • Page 38: Inserting The System Sd Card

    System characteristics 3.3 Memory card interface 3.3.2 Inserting the system SD card Inserting the system SD card Slot and mounting position: CAUTION Electrostatic Device (ESD) Before you touch a SD card, discharge yourself at the cabinet or at the ground terminal. The SD cards should only be inserted or removed when the control unit is disconnected from the power supply.
  • Page 39 System characteristics 3.3 Memory card interface 3. Gently insert the new SD card into slot until it clicks into place. The SD card has an edge on the opposite side to the pins. This edge must always be on the right when inserting the card. SD card slot Figure 3-12 SD card slot...
  • Page 40: System Overview

    System characteristics 3.4 System overview System overview Configuration with four axes The following configuration shows a typical example with SINAMICS S120 booksize: Figure 3-13 Configuration example 1: Configuration with four axes PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 41 System characteristics 3.4 System overview Configuration with 4 axes and 2 auxiliary axes The following configuration shows an example with 2 auxiliary axes: Figure 3-14 Configuration example 2: Basic expansion stage with 4 axes and 2 auxiliary axes PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 42 System characteristics 3.4 System overview Configuration with 6 axes and Safety Integrated The following configuration shows the expansion stage with SINAMICS S120 Combi: Figure 3-15 Configuration example 3: Expansion stage with 6 axes and with Safety Integrated PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 43: Application Planning

    Application planning Grounding concept Components The SINUMERIK ONE system consists of a number of individual components which have been designed so that the system complies with the appropriate EMC and safety standards. The individual system components are: ● Panel Processing Unit PPU ●...
  • Page 44: Emc Compatibility

    However, if the system cannot operate without them, then the cable shields must be connected at both ends. Furthermore, the non- Siemens device must be connected to the control via an equipotential bonding cable. Cable definitions The following cables are permissible: ●...
  • Page 45 Application planning 4.2 EMC compatibility ● If signal lines cannot be routed a sufficient distance away from other cables, they must be installed in grounded cable ducts (metal). ● The clearance (interference injection area) between the following lines must be kept to a minimum: –...
  • Page 46: Climatic And Mechanical Environmental Conditions

    Application planning 4.3 Climatic and mechanical environmental conditions Climatic and mechanical environmental conditions 4.3.1 Ambient conditions The components of the SINUMERIK ONE system exceed the requirements according to EN 61800‑2 with regard to shipping and storage conditions. The following data applies under the following conditions: ●...
  • Page 47: Transport And Storage Conditions

    Application planning 4.3 Climatic and mechanical environmental conditions 4.3.2 Transport and Storage Conditions Components in original packaging The following specifications apply to components in transport packaging: Transport Storage Standard / class EN 60721-3-2 EN 60721-3-1 Temperature range -20 ... + 60 °C -25 ...
  • Page 48 You must consider the radio interference for the complete system. Particular attention should be paid to cabling. Please contact your sales representative for assistance and support. If compliance with limit value class C2 is required, please contact your local Siemens sales partner.
  • Page 49: Recycling And Disposal

    Application planning 4.4 Recycling and disposal Recycling and disposal Figure 4-1 Recycle Products should be disposed of corresponding to the relevant national regulations. The products described in this manual can be mostly recycled due to the fact that they contain very few damaging substances.
  • Page 50 Application planning 4.4 Recycling and disposal PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 51: Installing

    Installing The PPU 1740 package contains the following elements: ● PPU1740 ● Bag of clamps ● Accessory bag (I/O and power supply connectors) ● Wiring diagram ● Safety instructions Installation notes The PPU modules and components may only be installed in housings, cabinets or in isolated electrical operating areas.
  • Page 52: Dimension Drawings For Ppu 1740 -1500

    Installing 5.1 Dimension drawings for PPU 1740 -1500 Dimension drawings for PPU 1740 -1500 PPU 1740 - 1500 Figure 5-1 PPU 1740 -1500 dimensions PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 53 Installing 5.1 Dimension drawings for PPU 1740 -1500 Figure 5-2 Cabinet for ventilation in PPU 1740 -1500 PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 54: Dimension Drawings For Ppu 1740-1900

    Installing 5.2 Dimension drawings for PPU 1740-1900 Dimension drawings for PPU 1740-1900 PPU 1740 - 1900 Figure 5-3 PPU 1740-1900 dimensions PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 55 Installing 5.2 Dimension drawings for PPU 1740-1900 Figure 5-4 Cabinet for ventilation in PPU 1740 -1900 PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 56: Installing The Ppu

    Installing 5.3 Installing the PPU Installing the PPU Prerequisite The PPU is attached to the operator panel housing by means of fixing clamps. Some of the prerequsites for installing the PPU are: ● Remove the foil which is used to protect the components during transport. ●...
  • Page 57 Installing 5.3 Installing the PPU 1. Insert the PPU into the installation cutout from the front. 2. Ensure all the 4 spring retainers on the top and bottom of the unit are fully engaged. If the unit is not fully engaged, then carefully push the unit into the mounting cutout at the position where it is not locked completely.
  • Page 58 Installing 5.3 Installing the PPU 4. Fix the fixing clamps by tightening the setscrew with flat-head screwdriver, torque 0.5 Nm. 5. Repeat steps 3 and 4 to attach all the fixing clamps in their respective positions. 6. Check for the mounting seal. Note Due to cooling effect, PPU1740 can only be assembled horizontally.
  • Page 59: Position Of Mounting Clips For Ip65 Installation

    Installing 5.4 Position of mounting clips for IP65 installation Position of mounting clips for IP65 installation Figure 5-5 PPU 1740-1500 Figure 5-6 PPU 1740-1900 PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 60 Installing 5.4 Position of mounting clips for IP65 installation PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 61: Service And Maintenance

    Service and maintenance Cleaning the device The device is designed for low-maintenance operation. Nevertheless, you must regularly clean the device. Note Switch the device off for cleaning Clean the device only when it is switched off. Clean only the front panel surface with e.g. soft cloth moistened with water or mild cleaning agent.
  • Page 62 Service and maintenance Protect the device from environmental effects Protect the device against the following environmental factors: ● Direct sunshine and heat sources ● Mechanical vibration and shock ● Dust ● Humidity ● Strong magnetic fields Suspected malfunction If you suspect a malfunction due to unusual product reactions, isolate the device from power. Immediately inform qualified personnel to check the function and ensure that the product functions correctly.
  • Page 63: Interface Description

    Interface description Interface overview Requirement DANGER Risk of electric shock Before you mount the SINUMERIK ONE or cable it, the complete system must be in a no- voltage condition. Definition The abbreviations used in "Signal type" column in the tables showing the pin assignment have the following meaning: Bidirectional Grounding...
  • Page 64 Interface description 7.1 Interface overview Connection options The following overview shows the interfaces and their connection options: Article number SINUMERIK ONE Prefabricated cable PPU 1740 X100 DRIVE-CLiQ cable SINAMICS S120 X101 ≤ 70 m DRIVE-CLiQ X102 X103 NX10.3/NX15.3 Drive: 12 digital inputs X122 8 digital inputs/outputs Digital I...
  • Page 65: Power Supply Connection

    PLC I/Os. If this is not the case in exceptional circumstances, the ground connection should be made on the grounding rail of the control cabinet. See also: "EMC Installation Guideline (https://support.industry.siemens.com/cs/de/de/view/ 60612658/en)" Configuration Manual. PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 66: Connecting The Power Supply

    Interface description 7.2 Power supply connection Table 7-1 Technical data of the DC power supply Rated voltage According to EN 61131-2 Voltage range (mean value) Voltage range (dynamic) Voltage ripple peak-to-peak Booting time at POWER ON Non-periodic overvoltages Duration of overvoltage Recovery time Events per hour Transient voltage interrup‐...
  • Page 67: Ethernet

    Interface description 7.3 Ethernet Ethernet The CPU-board of PPU1740 provides ethernet controllers for three GbE interfaces. The connectors for the interfaces X130 and X120 are located on the CPU-Board and the interface X127 is located on the Front-adapter, which is the interface to the backside of the panel. X130, X120, X127 pin assignment and use The interfaces are designed for operation in full-duplex mode;...
  • Page 68 Interface description 7.3 Ethernet Pin assignment For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange LED. This allows the following status information about the respective Ethernet port to be displayed: Table 7-2 Assignment of the Ethernet interfaces X120, X130 and X127 in 10/100 Mbit/s mode Connector Name Type...
  • Page 69 Interface description 7.3 Ethernet Note The Ethernet interfaces have what is called autocrossing functionality, i.e. when required, transmit and receive lines are switched over. Application Via the PROFINET interface, you can establish PROFINET IO communications networks between the PLC of the control and the field devices. ●...
  • Page 70 Interface description 7.3 Ethernet Table 7-5 Assignment of PROFINET interface X160 in the 10/100 MBit/s mode Connector Name Type Remark Bidirectional pair A+ Bidirectional pair A- Bidirectional pair B+ Bidirectional pair C+ Bidirectional pair C- Bidirectional pair B- Bidirectional pair D+ Bidirectional pair D- Shield On connector housing...
  • Page 71: Digital Inputs/Outputs

    Interface description 7.4 Digital inputs/outputs Digital inputs/outputs X122 pin assignment Signal name Meaning Digital input 0 Digital input 1 Digital input 2 Digital input 3 DI16 DI16 Digital input 16 DI17 DI17 Digital input 17 MEXT2 Ground for pins 1...6 P24EXT1 +24 V power supply DI/DO8...
  • Page 72 Interface description 7.4 Digital inputs/outputs Connecting the inputs and outputs: ● Recommended connection: Inputs and outputs connected to the same supply If both inputs and outputs are operated with the same 24 V supply. ● Not recommended connection: Inputs and outputs on different supplies NOTICE Exceeding the permissible input current If the inputs and outputs are supplied separately with power, the input current can exceed...
  • Page 73 Interface description 7.4 Digital inputs/outputs Signal name NC variable Meaning DOUT3 $A_OUT[3] Digital NC output 3 DOUT4 $A_OUT[4] Digital NC output 4 MEXT3 Ground for pins 9, 10, 12, 13 X252 pin assignment Signal name NC variable Meaning AOUT Analog output (voltage for analog axis/spindle) AGND Analog ground DIN9...
  • Page 74 Interface description 7.4 Digital inputs/outputs The following twelve inputs and eight inputs/outputs are used for drive control: ● At terminal X242, four inputs and four outputs are available for the NC. ● At terminal X252, four inputs and two outputs are available for the NC. Note Terminals MEXT1 ...
  • Page 75: Technical Data

    Interface description 7.4 Digital inputs/outputs 7.4.1 Technical data Digital inputs Parameter Value Voltage -3 V to 30 V Typical power consumption 9 mA at 24 VDC Signal level (including ripple) High: 15 V to 30 V Low: -3 V to 5 V Maximum signal propagation times L →...
  • Page 76 Interface description 7.4 Digital inputs/outputs Parameter Value Maximum output current for one connector (resistive) Maximum signal propagation times L → H: 50 μs H → L: 300 μs for 10 kΩ load PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 77: Drive-Cliq

    Interface description 7.5 DRIVE-CLiQ DRIVE-CLiQ 7.5.1 DRIVE-CLiQ interface X100 - X103 pin assignment Signal name Signal type Meaning Transmit data + Transmit data - Receive data + Reserved Reserved Receive data - Reserved Reserved Reserved Reserved DRIVE-CLiQ interfaces are used to connect SINAMICS S120 components to the PPU. It has the following properties: ●...
  • Page 78: Handwheel

    Interface description 7.6 Handwheel Handwheel X143 pin assignment Signal name Meaning 5 VDC power supply Ground Handwheel pulses track A, channel 1 Handwheel pulses track A (negated), channel 1 Handwheel pulses track B, channel 1 Handwheel pulses track B (negated), channel 1 5 VDC power supply Ground Handwheel pulses track A, channel 2...
  • Page 79 Interface description 7.6 Handwheel The following diagrams indicate the different data transfer types: ● Differential signal transfer: Note Differential signal transfer is the preferred technique, as it is insensitive to electromagnetic disturbances. ● Asymmetrical signal transfer: PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 80 Interface description 7.6 Handwheel Cable specification Feature Version Connector type: 12-pin screw terminal Cable type: Twisted pair, shielded Max. cable length PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 81: Usb

    Interface description 7.7 USB The USB interfaces correspond to the norm and are, therefore, not described in detail here. ● The X125 USB interface can be used to connect a USB-FlashDrive for transferring user and commissioning data. ● USB ports X135 and X145 (rear) is enabled for USB devices and for service. Cable specification The 5 V power supply is designed to be short-circuit proof.
  • Page 82 Interface description 7.7 USB PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 83: Connectable Components

    Connectable components NX10.3 / NX15.3 8.1.1 Description Properties Using the NX10.3 and NX15.3 modules, you can expand the performance of an axis group of a SINUMERIK ONE CNC automation system. Each NX10.3 can control up to 3 additional axes and each NX15.3 can control up to 6 additional axes. Type plate The NX module type plate contains the following information: Figure 8-1...
  • Page 84 Connectable components 8.1 NX10.3 / NX15.3 Display The NX module has the following interfaces: ● 4 DRIVE-CLiQ (X100 – X103) ● 6 digital inputs and 4 digital inputs/outputs (X122) ● Power supply (X124) Figure 8-2 Display of the NX module (without cover) PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 85: Nx10.3 / Nx15.3 Status Displays

    Connectable components 8.1 NX10.3 / NX15.3 8.1.2 NX10.3 / NX15.3 status displays LEDs for status display The following status displays on the NX modules provide information about its state: LEDs Color Status Description Electronic power supply outside permissible tolerance range Green Continuous light The NX10.3 / NX15.3 is ready.
  • Page 86: Mounting

    Connectable components 8.1 NX10.3 / NX15.3 8.1.3 Mounting Designs The NX10.3 / NX15.3 is integrated into the SINAMICS drive line-up. For the preferred installation sequence, the NX module should be mounted at the side of the Line Module. NOTICE Protection against overheating The 80 mm ventilation spaces above and below the components must be observed.
  • Page 87: Dimension Drawing

    Connectable components 8.1 NX10.3 / NX15.3 Mounting an NX10.3 / NX15.3 onto an Active Line Module Procedure: 1. Remove the spacers from the NX. 2. Position the NX on the left-hand side of the Line Module. The mounting fixtures fit exactly in the five cutouts on the NX.
  • Page 88: Connecting

    Connectable components 8.1 NX10.3 / NX15.3 8.1.5 Connecting X124 power supply pin assignment Connector designation: X124 Connector type: Screw terminal 2 Max. connectable cross-section: 2.5 mm Signal name Meaning (Voltage input) Electronics power supply (Voltage input) Electronics power supply (Voltage output) Ground (Voltage output) Ground...
  • Page 89 Connectable components 8.1 NX10.3 / NX15.3 Signal name Meaning DI16 Digital input 16 DI17 Digital input 17 Reference potential for terminals 1 to 6 Ground DI/DO8 Digital input/output 8 (rapid input) DI/DO9 Digital input/output 9 (rapid input) Ground DI/DO10 Digital input/output 10 (rapid input) DI/DO11 Digital input/output 11 (rapid input) Ground...
  • Page 90 Connectable components 8.1 NX10.3 / NX15.3 Connection example The digital inputs/outputs are connected appropriately during commissioning. Rapid inputs must be shielded. Jumper open, electrical isolation for digital inputs (DI) Can be parameterized as either input or output Figure 8-5 Connection example for the NX10.3 / NX15.3 See also For the pin assignment of the DRIVE-CLiQ interfaces X100 - X103, please refer to Section "DRIVE-CLiQ (Page 77)".
  • Page 91: Technical Data

    Connectable components 8.1 NX10.3 / NX15.3 8.1.6 Technical Data Technical data of the NX10.3 / NX15.3 Parameter Value Input voltage 24 V DC Permissible range 20.4 V - 28.8 V DC Current 0.8 A (without DRIVE-CLiQ and digital outputs) Inrush current 1.6 A PE/ground connection At the housing with screw M5/3 Nm...
  • Page 92 Connectable components 8.1 NX10.3 / NX15.3 PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 93: Technical Data

    Technical data PPU 1740-1500 Parameter PPU 1740-1500 Input voltage 24 VDC + 20% / - 15% (20,4V…28.8V) Rated current 24V 3.9A Inrush current 24V 6A Power consumption, max. (Pmax) Power loss Digital output 24V 0.5A* Cooling Open-circuit ventilation Degree of protection according to EN 60529 IP65 (front) IP20 (rear) Protection class according to EN 61800-5-1...
  • Page 94 Technical data Parameter PPU 17400-1900 Power loss Digital output 24V 0.5A* Cooling Open-circuit ventilation Degree of protection according to EN 60529 IP65 (front) IP20 (rear) Protection class according to EN 61800-5-1 III (DVC A, PELV) Pollution degree according to EN 61800-5-1 Display: Size 19 inch...
  • Page 95: Relevant Directives And Standards

    You can obtain an up-to-date list of currently certified components on request from your local Siemens office. If you have any questions relating to certifications that have not yet been completed, please ask your Siemens contact person. The certificates can be downloaded from the Internet: Certificates (https://support.industry.siemens.com/cs/ww/en/ps/14590/cert)
  • Page 96 SIUMERIK ONE devices showing the test symbols fulfill the EMC requirements for Australia and New Zealand. ● Quality systems Siemens AG employs a quality management system that meets the requirements of ISO 9001 and ISO 14001. ● Electric shock due to connection of an unsuitable power supply...
  • Page 97 Technical data 9.1 Relevant directives and standards Ground symbols Icon Meaning Ground (e.g. M 24 V) Connection for function potential bonding Connection for protective conductor PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 98 Technical data 9.1 Relevant directives and standards PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 99: Spare Parts And Accessories

    Spare parts and accessories Ordering data SINUMERIK ONE is generally marketed in sales packages with drives, motors and accessories. For orders, please contact your local Siemens sales representative. Designation Article number Panel Processing Unit without system software 6FC5317-4AA00-1CA0 ● PPU 1740-1500 6FC5317-4AA00-1DA0 ●...
  • Page 100 Spare parts and accessories PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 101: Appendix

    Appendix 11.1 Abbreviations Active Line Module ASIC Application Specific Integrated Circuit American Wire Gauge BERO Proximity limit switch CAT5 Quality class (category) for shielded twisted pair network cables. Class 5 states that these cables have a particularly low damping factor, making them suitable for 100 Mbit/s-FastEthernet networks. The CE marking (Conformité...
  • Page 102 Appendix 11.1 Abbreviations Random Access Memory: Program memory which can be read and written into Safety Integrated Smart Line Module Cabinet-mounted sensor modules Sensor Module External Steps per revolution: Pulses per revolution SRAM Static Random Access Memory: Static memory (battery-backed) NV SRAM Non-Volatile Static Random Access Memory: Non-volatile memory Universal Serial Bus: Bus system for connecting additional devices to a computer...
  • Page 103: Documentation Overview One

    Comprehensive documentation about the functions provided in SINUMERIK ONE Version 6.13 and higher is provided in the Documentation overview SINUMERIK ONE (https:// support.industry.siemens.com/cs/ww/en/view/109768483). You can display documents or download them in PDF and HTML5 format. The documentation is divided into the following categories: ●...
  • Page 104 Appendix 11.2 Documentation overview ONE PPU 1740 Equipment Manual, 01/2019, A5E47615272B AA...
  • Page 105: Index

    Index Air-conditioning Finger gestures, 35 Storage and transport, 47 Function-impairing dust, 48 Application overview, 17 Axis expansion, 83, 86 Grounding measures, 43 Benefits, 17 Booting the basic system, 31 Industrial Ethernet, 21 Installing PPU, 56 Interface PROFINET, 69 Cable specification, 67 Cables Digital inputs/outputs, 74 Ethernet, 67...
  • Page 106 Index Pin assignment Work gloves, 34 Digital inputs/outputs, 71, 72 DRIVE-CLiQ, 77 Ethernet, 67 Handwheel, 78 Power supply, 65 PLC mode selector switch, 33 Power cables, 44 Power supply 24 VDC, 65 Prerequisite Install PPU, 56 PROFINET, 21 Pin assignment, 69 Radio interference, 48 Recommended gloves, 34 SD card interface, 37...