NV35MR
Installation Manual V2.0
Wireless Outdoor/Indoor Dual Band
Window and Sliding Door Dual
Detector with Anti-Masking and Pet
Immunity
NV35MR-EI09
06/2019
General Description NV35MR
Thank you for choosing the NV35MR Wireless for your professional
protection needs. The NV35MR wireless Dual Band version will
provide you the most advanced window and sliding doors protection
either in Pet Immune or Sharp mode. If you have any comments
please write to us at Paradox.com/products/feedback.
Pet Recommended Installation (please read)
The NV35MR has been designed to be installed within the frame of
windows and doors when installed outdoors. This will ensure the best
performance against false alarms when random pets such as birds,
cats and small dogs access the window sill. Other installation methods
can be used with the NV35MR such as wall beam protection but if
installed outside of the frame its pet immunity may be compromised.
Installing the NV35MR
1. Remove the front cover - open the Captive screw.
Front
cover
Captive screw
Figure 1 – Removing the
Figure 2 – Main
Front Cover
2. Remove the Main Unit: open the two snap-lock mechanisms on
each side of the back cover attaching the Main Unit to the back
cover as displayed below. Then remove the Main Unit.
Figure 4 – Removing the Main Unit
3. Mount the back cover of the NV35MR onto the window frame or
wall using screws.
An optional mounting bracket for the NV35M is available for ordering,
part number: SB35.
Mounting
screw 1
Tamper
knockout
hole
Tamper
screw 2
Figure 3 – Back Plate
Unit
4 cm /
1.5 in.
4. Attach the Main Unit to the back cover - ensure the locks snap
closed.
1
Figure 5 – Attaching the Main Unit
5. Insert two AA batteries.
6. Set the following Detector settings according to requirements.
Sensitivity Trimmer
Default Sensitivity level: 2
LED flashes green 1-3 times
according to the selected level.
Figure 6 – Detector Settings
The following table displays the Dip Switch settings.
Table 1: DIP Switch Functionality
Dip Switch
Function
Number
1
LED
2
PET Immunity/
SHARP Mode
3*
RF
4
Anti-mask
5
Anti-mask
Sensitivity
Note: PLEASE KEEP AT LEAST 4 cm / 1.5 in. clearance from window/
shutter.
* For USA and Canada: 433MHz frequency is set by the manufacturer
and cannot be modified.
7. Replace the front cover and close the Captive screw.
Do not obscure the detector's field of view.
Note: Tamper must be enabled on SP panels.
Testing the NV35MR
Perform a Walk-Test to test successful installation: Walk slowly
across the far end of the detection range and ensure detection.
Walk test mode lasts 5 minutes after the tamper screw is closed.
2
3
DIP
Switches
Mode Description
: LED on (default)
ON
: LED off
OFF
: PET Immunity mode (default)
ON
: SHARP mode
OFF
: 433.92 MHz
(default)
*
ON
: 868.35 MHz- applicable for
OFF
EU versions only
: On (default)
ON
: Off
OFF
: High (default)
ON
: Low
OFF
PARADOX.COM