hit counter script
Launch VALUE-500 Manual

Launch VALUE-500 Manual

Mobile refrigerant recovery recycling and charging unit

Advertisement

NOTE:
Carefully read the user manual before using, and keep it well for future reference.
Carefully check the device parts list before using.For any doubt, contact Launch distributor
immediately.
Due to the product upgrade, tiny difference between the user manual and the device will not be
further noticed. Take the device as standard.
Copyright reserved! Without written agreement from Launch Tech Co., Ltd (Hereinafter refer to "Launch"),
any company or person is not allowed to copy and duplicate this user manual in any format (electronic,
mechanical, video, record or other formats).The user manual is designed only for Launch products. Any
consequence caused by using the user manual to guide other device operation is not under the
responsibility of Launch.
Launch and its branches are not responsible for the fees and expense of the device damage and loss due
to private accident or from third party, misuse and abuse of the device, unauthorized change and repair,
or any operation and maintenance not following Launch standard.
Launch is not responsible for device damage or problem due to the usage of any optional parts or
consumables instead of Launch original products or Launch recognized products.
Declaration: Other product names mentioned in the user manual are aimed to describe the device usage.
The registered trademarks still belong to the original company.
The device is for professional technicians or maintenance and repair personnel.
Registered Trademark
Launch has registered its trademark in China and several other countries, logo is
trademarks, service marks, dot names, Icons, company names mentioned in the user manual all belong
to Launch and its subsidiaries.In those countries where Launch trademark, service mark, dot name, icon,
company name not registered yet, Launch declaim the right for its unregistered trademark, service mark,
dot name, icon, and company name.Trademarks of the other products and company names mentioned in
the user manual still belong to original registered company.Without written agreement from the owner, no
person is allowed to use the trademark, service mark, dot name, icon and company name of Launch or of
other mentioned companies.You can visit http://www.cnlaunch.com or write to Customer Service Center
of LAUNCH TECH CO., LTD at Launch Industrial Park, North of Wuhe Avenue, Banxuegang, Longgang
District, Shenzhen, P.R.China, to get contact with Launch for the written agreement on the usage of the
User Manual.
.Other Launch

Advertisement

Table of Contents
loading

Summary of Contents for Launch VALUE-500

  • Page 1 Launch. Launch and its branches are not responsible for the fees and expense of the device damage and loss due to private accident or from third party, misuse and abuse of the device, unauthorized change and repair, or any operation and maintenance not following Launch standard.
  • Page 2 VALUE-500 Mobile Refrigerant Recovery Recycling and Charging Unit (Touchscreen Version)...
  • Page 3: Table Of Contents

    Contents Safety Precaution ………………………………………………………………………………………………………………………... Equipment Introduction ……………………………………………………………………………………………………………... Appearance Introduction ……………………………………………………………………………………………………….……… Outside view …………………………………………………………………………………………………………………….. II. Rear view ……………………………………………………………………………………………………… .…………..III. Side view ………………………………………………………………………………………………………………..… IV. Operation panel ……………………………………………………………………………………………………………………..V. Internal structure… ………………………………………………………………………………………………………………...…..Device Connection to Car (as shown below) ……………………………………………………………..…..H i g h a n d L o w P r e s s u r e...
  • Page 4: Safety Precaution

    Safety Precaution 1. Read this manual before using the unit to become familiar with its specifications and operation. 2. The operator must be familiar with repair and maintenance of air conditioning to avoid damaging equipment and mobile refrigeration systems. 3. Always wear protective gloves and safety goggles when working. Contact with refrigerant may cause injury.
  • Page 5: Equipment Introduction

    Equipment Introduction This Mobile Refrigerant Recovery Recycling and Charging Unit serves for automotive repair shop, used in the recovery and charging of refrigerant in the R134a air conditioning system, providing services like automatic refrigerant recycling, charging, vacuuming and refrigerant oil refilling, etc. Functions: Refrigerant cylinder refill It can refill refrigerant into the refrigerant cylinder.
  • Page 6 - 3 -...
  • Page 7: Appearance Introduction

    Appearance Introduction 1 Outside View 2 Rear View Power switch Handle AC-220V Vial filling valve Fuse Remove the retaining screw before using - 4 -...
  • Page 8: Side View

    3 Side View Refrigerant oil inlet Used oil bottle 4 Operation Panel High Pressure Valve Window Low Pressure Valve Touchscreen - 5 -...
  • Page 9: Internal Structure

    5 Internal Structure Filling valve internal refrigerant cylinder Vacuum pump Heat exchanger Dry filter Oil separator Compressor (Picture1) Oil discharge solenoid valve Condenser Cooling fan (Picture2) - 6 -...
  • Page 10: Device Connection To Car

    Filling pipe ball valve Recycling pipe Recycling pipe ball valve (blue) Filling pipe (red) Internal refrigerant cylinder Electronic scale for internal liquid reservoir Electronic scale protection screw (Picture 3) Device Connection to Car (as shown below) - 7 -...
  • Page 11 High and Low Pressure Valves Operating Guideline During operation, the system will prompt several times to turn on/off the high and low pressure valves. Operation Definition: 1.Turn off the high and low pressure valves As shown below, turn off the high/low pressure valve is to tighten the valves counterclockwise based on the reverse direction of the arrow (the arrow marked “open”...
  • Page 12: Preparation Before Use

    2.Turn on the high and low pressure valves As shown below, turn on the high and low pressure valves is to tighten the valves clockwise based on the direction of the arrow (the arrow marked “open” on the valve) on the high and low pressure valves. Rotate the quick couplings clockwise air conditioning...
  • Page 13: Operation Procedures

    2.Using Refrigerant Refill function to add about 3kg refrigerant into the equipment (refer to the procedures of Refrigerant Cylinder Refill) Operating procedures Refrigerant Cylinder Refill The tank contains no refrigerant as leaving the factory. Refrigerant must be refilled before operation. The recommended refill weight is 3-6kg. Operation is as follows. 1.
  • Page 14: Recycle

    Input the quantity of refrigerant and click “Run”, then wait until it prompts the operation is complete. After the required vacuum has been obtained, the system shows the following interface: operator should follow the instruction and click “Confirm” to continue. After the procedure completed normally, the system shows the following interface: click “Exit”...
  • Page 15: Vacuum

    Vacuum Click “Vacuum” in the main interface to enter vacuum procedure. After the system shows the following interface, click plus or minus to set time, then select “run”. Any refrigerant in the pipeline would be recycled automatically, then the vacuum procedure would start. Dwell time comes after vacuum procedure.
  • Page 16: Charge

    After entering the oil charging procedure, ensure oil inside the refrigerant oil vessel is not less than 50g, then long press “OK” to start and release to stop. Exit the system upon completion. 4.Charge On the homepage, double-click "charging" to enter the filling procedure You can select the large or the small bottle filling.
  • Page 17: Purge

    After the filling is complete, follow the prompts to turn off your vehicle high and low pressure valves, press "OK" to run the recovery of refrigerant in the equipment pipelines. Press exit upon completion. 5.Purge Purge function is to clean the car piping system. Enter the cleaning procedure, press plus or minus to add or reduce the forward and reverse cleaning time, and to set the number of cycles.
  • Page 18 - 15 -...
  • Page 19: Quick Maintenance

    After cleaning is complete, it will automatically enter the recycling procedure. Press “exit” upon completion. 6.Quick Maintenance On the homepage, click “Fast Service” to enter the procedure. - 16 -...
  • Page 20 Press plus or minus to add or reduce the forward and reverse cleaning time, and to set the number of cycles. Before cleaning, ensure that there is more than 2KG refrigerant in the tank, then press "OK" to start. After the cleaning is complete, it will automatically recycle the refrigerant. - 17 -...
  • Page 21 After recovery, it will automatically enter the vacuum procedure. After the vacuum is complete, the equipment will sound a beep, and start to maintain pressure. If there is no leakage in the pipeline, you could skip this procedure and fill the refrigerant oil into refrigerant cylinder manually.
  • Page 22 Then it will automatically enter manual filling refrigerant procedure. You can select the large or the small bottle filling. After selecting the fill mode, ensure that there is sufficient refrigerant. Then long press “OK” to start, and release to stop. After completion, press “EXIT”, it will automatically enter the pipeline recycling procedure.
  • Page 23: Equipment Maintenance

    Press “exit” upon completion. 7.Equipment Maintenance Click “Equipment Maintenance” in the main interface to enter the maintenance procedure. - 20 -...
  • Page 24: Reset Of Electronic Scale

    ① Electronic Scale Calibration Remove jars and other sundries(except tray) on the electronic scale. First input the weight of reference weight parameter, “2000g” for example. Then click “OK” and go on to the next step. Place 2kg weight(should be equal to the weight input in previous step) on the tray. Wait until the parameter become unchanged and click “OK”...
  • Page 25: Equipment Information

    ②Electronic Scale Reset Ensure there is no refrigerant inside the cylinder. Wait until weight parameter become unchanged and click “OK” to finish intelligent reset. ③Equipment Information - 22 -...
  • Page 26 ④Filter Parameter After the replacement of filter, enter the interface of filter parameter. Enter the password and reset the service time of the filter. - 23 -...
  • Page 27 The warranty clause is only applicable to users and distributors who purchased Launch products via the regular process. Within 1 year since the delivery, Launch guarantee the products damaged due to the material or craft defects. Any damage to the device or part due to abuse, unauthorized change, usage other than designed to, operation not following the user manual, etc.
  • Page 28 We have tried our best to make all the descriptions in the book accurate, but there are still some inconveniences. If you have any questions, please contact the dealer or LAUNCH Service Center. The company will not bear any consequences due to misunderstanding.

Table of Contents