Page 1
FLOOD SENSOR Engineering Specification Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your z-wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.
Page 2
2. Specifications Power supply: ER14250 3.6V Battery Storage environment: -10℃-50℃ 0%-90% Operational temperature: 0-40℃ Radio protocol: Z-Wave plus Radio frequency: 868.42MHz (EU) 908.42MHz (US) 921.42MHz(ANZ) Range: More than 100m outdoors About 30m indoors (depending on building materials) Dimensions: Main body: 68 mm(Φ)*22mm(H) Extension probe: 50 mm(Φ)*5mm(H) Wire: 1000mm(L) Working current:...
Page 3
2. Remove the battery blocker. NOTE: When powered, the device will indicate Z-Wave status with LED: 1. Blink slowly: the device is not added to any Z-Wave network. 2. Solid: the device is already added to the Z-Wave network. 3. Add the device (see “Adding/removing the device” on page 5). 4.
Page 4
5. Place the sensor on a surface prone to flooding, or use the extension probe(see “Installation” on page 4). Ⅱ. INSTALLATION Flood Sensor should not be mounted directly on or near metal framing or other large metallic objects since metal objects may weaken the radio signal strength. After “activation”...
Page 5
NOTE: Wipe clean the surface where the flood sensor will be mounted. Any dust and particles can reduce the adhesion of double-sided mounting tape. Ⅲ. ADDING/REMOVING THE DEVICE Included as a secure device (S0 or S2) 1) Open the cover. 2) Place the device within the direct range of your Z-Wave controller.
Page 6
ecurity enabled Z-Wave controller is needed. Removing 1) Open the cover. 2) Place the device within the direct range of your Z-Wave controller. 3) Set the main controller remove mode (see the controller’s manual). 4) Triple click the Z-button quickly, the LED indicator should blink fast in orange. 5) Wait for the removing process to end.
Page 7
Z-Button is released, this procedure will reset the Sensor to factory default. Ⅴ. RESETTING Reset procedure clears the flood sensor's memory, including Z-Wave network controller information and advanced configuration. To reset a Flood Sensor: Press and hold the Z-button for more than 20 seconds and than release. NOTE Use this procedure only in the event that the network primary !...
Overheat detected, Unknown Location(0x02) Heat Alarm(0x04) Under heat detected, Unknown Location(0x06) Water Alarm(0x05) Water leak detected, Unknown Location(0x02) Home Security(0x07) Tampering, Product covering removed(0x03) a. When the Overheat detected, send Heat Alarm (04) and Overheat detected, Unknown Location(0x02); b. When Under heat detected, send Heat Alarm (04) and Under heat detected, Unknown Location(0x06);...
Page 9
Setting examples: 0~3599 = 0 second, the device will not wake up by itself. 3600~7199= 3600seconds, the device will wake up every 3600 seconds. . Battery command Ⅷ 1. When sending Battery get command to the product, the product will report the current battery power when it wakes up.
Page 10
Flood sensor can send BASIC SET command to nodes associated with group 2. 0 – Disable. 1 – Enable. Default setting: 0 Parameter size: 1 [byte] Parameter No.15 Value of the BASIC SET Flood sensor can reverse its value of BASIC SET when flooding is triggered. 0 –Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered.
Page 11
Available settings(US): -670 - 2570(-67 – 257°F) Available settings(Other): -550 - 1250(-55 – 125°C) Default setting (US): 320 (32°F) Default setting (Other): 0 (0°C) Parameter size: 2[byte] Parameter No.24 Enable/Disable blinking LED when alarm being triggered 0 –Disable. 1 –Enable. Default setting: 1 Parameter size: 1[byte] Parameter No.32 Level of low battery...