Chapter 2 Preparations
Backplane for 2.5-inch hard disk drives when a 2.5-inch HDD cage is installed
(a)
Using the on-board RAID controller (LSI Embedded MegaRAID
Jumper on motherboard (SWRAID)
Change jumper setting to 2-3 (Enabled).
[Using 2.5-inch hard disk drive]
Backplane for 2.5-inch hard disk drive provided with 2.5-inch HDD cage (J7)
Change jumper setting to 1-2 (Onboard SATA controller).
[Using 3.5-inch hard disk drive]
No setting other than the jumper on the motherboard is required.
Configure the RAID system using EXPRESSBUILDER or LSI Software RAID Configuration Utility after
changing the jumper.
For details, see Chapter 2 (4. RAID System Configuration) or (5. Details of EXPRESSBUILDER) in
"Maintenance Guide".
56
Optional RAID
Controller
3 2 1
Express5800/T110f-S User's Guide
1. Installing Internal Optional Devices
J7 jumper
On-board SATA
Controller
3 2 1
TM
)