  • Page 1 Power Systems Installing the IBM Power System S824L (8247-42L) GI11-9911-02...
  • Page 3 Power Systems Installing the IBM Power System S824L (8247-42L) GI11-9911-02...
  • Page 4 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 27, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ™...
  • Page 5: Table Of Contents

    Safety notices ....... .. Installing the IBM Power System S824L (8247-42L) ....
  • Page 6 Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 7: Safety Notices

    You should also refer to the safety information documentation any time you do not clearly understand any safety information in the U.S. English publications. Replacement or additional copies of safety information documentation can be obtained by calling the IBM Hotline at 1-800-300-8751.
  • Page 8 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 9 Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 10 DANGER: Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) viii Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 11 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. (L002) (L003) Safety notices...
  • Page 12 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product. Consult the label on each part for laser certification numbers and approval information. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 13 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
  • Page 14 (C048) Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS (Network Equipment-Building System) GR-1089-CORE: The equipment is suitable for installation in the following:...
  • Page 15 Note: All Ethernet cables must be shielded and grounded at both ends. The ac-powered system does not require the use of an external surge protection device (SPD). The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground.
  • Page 16 Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 17: Installing The Ibm Power System S824L (8247-42L)

    Use the information to understand the prerequisites that are required for installing the server. You might need to read the following documents before you begin to install the server: v The latest version of this document is maintained online. See Installing the IBM Power System S824L (8247-42L) (http://www.ibm.com/support/knowledgecenter/POWER8/p8egk/p8egk_kickoff.htm).
  • Page 18: Completing Inventory For Your Server

    If you have incorrect, missing, or damaged parts, consult any of the following resources: v Your IBM reseller. v IBM Rochester manufacturing automated information line at 1-800-300-8751 (United States only). v The Directory of worldwide contacts website http://www.ibm.com/planetwide. Select your location to view the service and support contact information.
  • Page 19 Note: Mark the rack so that these marks can also be seen from the rear of the rack. d. Count up two holes and place another mark (B) beside that mounting hole. You now have two (B) marks on the rack, with one mounting hole between the marks. Installing the IBM Power System S824L (8247-42L)
  • Page 20: Attaching The 8247-42L Mounting Hardware To The Rack

    You might need to attach the mounting hardware to the rack. Use the procedure in this section to perform this task. This section also includes illustrations of the related hardware components and shows how these components relate to each other. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 21 Do not install mismatched hardware by using washers or spacers. If you do not have the correct rails and fittings for your rack, contact your IBM reseller. Important: To complete this procedure, it is suggested that you use two people to attach the rail assembly to the rack.
  • Page 22: Installing The Server Into A Rack

    Use one M5 screw (E), below the lower rail pin (D) to secure the right rail to the front of the rack. Installing the server into a rack Learn how to install the system into the rack. CAUTION: This system requires three people to install the system into the rack. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 23 2. Lift the blue release latches (1) on the slide rails and push the server (2) all the way into the rack until it clicks into place. Figure 7. Release latches and server Installing the IBM Power System S824L (8247-42L)
  • Page 24: Installing The Cable-Management Arm

    (2). Note: The support arm (A) is labeled UP and DOWN. Ensure that the side labeled UP is facing upward and to the right. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 25 4. Attach the cable-management stop bracket (B) to the slot on the inside of the left slide by sliding the stop bracket (B) into the slide rail until the spring-loaded pin snaps into place. For details, see Figure 11 on page 10. Installing the IBM Power System S824L (8247-42L)
  • Page 26 6. Attach the cable-management stop bracket (B) to the slot on the inside of the left slide by sliding the stop bracket (B) into the slide rail until the spring-loaded pin snaps into place. For details, see Figure 13 on page 11. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 27 (2). Push the tab until the spring-loaded latch snaps into place. For details, see Figure 14 and Figure 15 on page 12. Figure 14. Sliding the cable-management arm tab into the mounting bracket slot Installing the IBM Power System S824L (8247-42L)
  • Page 28: Cabling The Server With An Ascii Terminal

    1) Connect the system power cords from the server and I/O drawers to the PDU with an IEC 320 type receptacle. 2) Attach the PDU input power cord and plug it into the power source. 3) If your system uses two PDUs for redundancy, complete the following steps: Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 29: Cabling The Server

    If your system has two power supplies, attach one power supply to each of the two PDUs. v If your system has four power supplies, plug E1 and E2 to PDU A and E3 and E4 to PDU Installing the IBM Power System S824L (8247-42L)
  • Page 30: Completing Server Setup

    Use the information to understand the prerequisites that are required for setting up the preinstalled server. You might need to read the following documents before you begin to install the server: Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 31: Completing Inventory For Your Preinstalled Server

    The latest version of this document is maintained online. See Installing the IBM Power System S824L (8247-42L) (http://www.ibm.com/support/knowledgecenter/POWER8/p8egk/p8egk_roadmap.htm). v To plan your server installation, see Planning for the system (http://www.ibm.com/support/ knowledgecenter/POWER8/p8had/p8had_8xx_kickoff.htm). Consider the following prerequisites before you install the server:...
  • Page 32 Store the shipping bracket if you want to move your system at a later date. 2. Cable the server. a. Plug the power cords into the power supplies and attach the cables to the handles on the power supplies using cable ties or hook-and-loop fasteners. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 33: Cabling The Server With An Ascii Terminal

    Plug the system power cords and the power cords for any other attached devices into the power source. c. If your system uses a power distribution unit (PDU), complete the following steps: Installing the IBM Power System S824L (8247-42L)
  • Page 34: Routing Cables Through The Cable-Management Arm And Connecting Expansion Units

    1. Route the console cable through the cable management arm. 2. Continue with “Completing server setup.” Completing server setup Use this procedure to complete your server setup. To complete the server setup, complete the following steps: Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 35 Install and configure Ubuntu b. Update system firmware c. Update the Ubuntu operating system d. Configure and use the NVIDIA CUDA toolkit 2. You have now completed the steps to install your server. Installing the IBM Power System S824L (8247-42L)
  • Page 36 Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 37: Common Information For Installing Servers

    Flashing 110 volts are being applied. This system requires 220 volts. The following table describes system reference codes (SRCs) that you might encounter during installation. © Copyright IBM Corp. 2014, 2015...
  • Page 38: Best Practices For Integrating Cable And System Placement

    This applies to installing them into the cable management arm and retaining them to the rack, brackets, and other features that may be provided for cable management. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 39 Figure 18. Cable management cable lanes v Use the innermost cable-management bridge lanes for SPCN cables. v Use the middle cable-management bridge lanes for power and communications cables. v The outermost row of cable-management bridge lanes are available for use when routing cables. v Use the cable lanes on the sides of the rack to manage excess SPCN and power cables.
  • Page 40: Supporting Information For Setting Up Consoles

    From the Tools menu in Microsoft Internet Explorer, select Internet Options. b. From the Internet Options window, click the Advanced tab. c. Clear the Use TLS 1.0 check box (in the Security category) and click OK. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 41: Setting The Ip Address On Your Pc Or Notebook

    If you plan to connect your PC or notebook to your network, see Accessing the ASMI without an HMC (http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p8hby/ connect_asmi.htm). Setting the IP address on your PC or notebook To access the Advanced System Management Interface (ASMI) through a web browser, you first need to set the IP address on a PC or notebook.
  • Page 42: Windows Vista

    Move the reset toggle switches on the service processor from their current position to the opposite position. To perform this task, you must remove and replace the service processor. For details, contact your next level of support. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 43: Notices

    This information was developed for products and services that are offered in the USA. This material may be available from IBM in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it.
  • Page 44: Trademarks

    IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 45: Electronic Emission Notices

    Class A Notices The following Class A statements apply to the IBM servers that contain the POWER8 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information.
  • Page 46 Electromagnetic Interference (EMI) Statement - People's Republic of China Declaration: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may need to perform practical action. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 47 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 48: Class B Notices

    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 49 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 50 Confirmed Harmonics Guideline with Modifications (products greater than 20 A per phase) IBM Taiwan Contact Information Electromagnetic Interference (EMI) Statement - Korea Germany Compliance Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse B EU-Richtlinie zur Elektromagnetischen Verträglichkeit Power Systems: Installing the IBM Power System S824L (8247-42L)
  • Page 51: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 52 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.
  • Page 53 Notices...
  • Page 54 IBM® Part Number: 00RW899 Printed in USA GI11-9911-02...

This manual is also suitable for:

8247-42l

Table of Contents