Page 1
Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 10 331 580...
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
Page 5
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions. Contact Miele’s Technical Service Department for examination, repair or adjustment.
Page 6
Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults. Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safety of the appliance.
Page 7
IMPORTANT SAFETY INSTRUCTIONS If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: –...
Page 8
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
Page 9
IMPORTANT SAFETY INSTRUCTIONS Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers unattended. Never leave an electric grill unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood.
Page 10
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Page 11
Wear gloves to protect your hands from being cut. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
Page 12
Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
Page 13
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference.
Description of functions The following functions are available on your ventilation hood, depending on the model: Vented mode The cooking vapors are drawn in by the ventilation hood. The air is then passed via the edge extraction panel through the grease filters, cleaned and then directed outside.
Page 17
Guide to the appliance a Vent connection Extraction ducting can be directed through the back of the ventilation hood, upwards to the ceiling, or to the side. b Overhead cooktop lighting c Active charcoal filters (x 2) Optional accessory for recirculation mode d Grease filters e Edge extraction panel f Control panel...
Operation (Automatic mode) When Con@ctivity 2.0 is active, the Reaction time hood always operates in Automatic Changing the power setting on the mode (see "Activating Con@ctivity cooktop does not lead to an immediate 2.0"). increase or decrease in cooking vapors. See "Cooking without Con@ctivity 2.0"...
Page 19
Operation (Automatic mode) Cooking process Deactivation If, for example, you switch on a Turn off all burners. burner at the highest power setting to Over the next few minutes, the heat cookware in preparation for ventilation hood fan setting will searing and then reduce the power decrease one level at a time until the level after approx.
Operation (Automatic mode) Temporarily exiting Automatic Resuming Automatic mode mode The ventilation hood resumes Automatic mode: To temporarily exit the Automatic mode when cooking: If the ventilation hood has not been used for a period of approx. 5 Manually select a different fan level, minutes after the manual selection of a fan level, or ...
Operation (Manual mode) With the Delayed shut down function, it Cooking without Con@ctivity is possible to have the fan automatically 2.0 (Manual mode) shut off after a predetermined period of The hood can be operated manually if: time. – The Con@ctivity 2.0 function is not ...
Operation (Manual mode) The 1 and IS indicators will flash. Power management To turn it on, press the "" button. The ventilation hood features a power management system to help save The 1 and IS indicators are constantly energy. The fan power level is reduced lit.
Operation (Automatic and Manual modes) Fan power level indicators 1 to IS show Filter saturation indicator the current time setting: The number of hours the hood has Indicator 1 ....... 20 hours been in operation is stored in appliance memory. Indicator 2 .......
Operation (Automatic and Manual modes) Activating/changing the charcoal Checking the elapsed operating time filter saturation counter Before the set operating time interval Charcoal filters are necessary for has been reached, you can check what recirculation mode. percentage of the time has elapsed. The filter saturation counter for the ...
Energy-saving tips This hood operates in a very efficient – Clean or change the filters at regular and energy-saving manner. The intervals. Heavily soiled filters reduce following will help you to save even performance, increase the risk of fire more energy when using it: and are unhygienic.
Stainless steel surfaces can also be cleaned using a non-abrasive Before cleaning or servicing the stainless steel cleaner, available from hood, disconnect it from the power Miele. supply, see "IMPORTANT SAFETY INSTRUCTIONS". To prevent the surfaces from quickly becoming dirty again, we recommend...
Cleaning and care Important for the controls Grease filters and edge extraction panel Do not leave dirt and debris on the buttons for any length of time. The edge extraction panel and the Otherwise they may become reusable metal grease filters in the discolored or damaged.
Page 28
Cleaning and care Removing the panel and grease filters The panel and grease filter can fall out when you are handling them. This can result in damage. Make sure you hold the panel and the grease filters securely at all times when handling them.
Page 29
Select a program with a wash temperature between 120°F (50°C) Unsuitable cleaners can cause damage and 150°F (65°C). In a Miele to the filter surfaces if used regularly. dishwasher use the "Normal" Do not use any of the following: program.
Page 30
Cleaning and care After cleaning After cleaning, leave the filters on an absorbent surface to dry. When removing the panel and filters for cleaning, also clean off any accessible oil or grease buildup from the housing. Doing so will prevent a fire hazard.
Charcoal filters are available from your Press the filter saturation indicator dealer or from Miele Service. for approx. 6 seconds until 1 is the only indicator flashing. You will need to order a DKF 19-1 charcoal filter set.
Cleaning and care Installing/replacing the charcoal filter When to change the OdorFree Charcoal Filter Before installing or replacing the Always replace the OdorFree charcoal filters, the panel and the grease filters must first be taken out Charcoal Filters whenever they no (see previous section for instructions longer absorb kitchen odors on how to do this).
Installation The ventilation hood is intended for Before installation installation in wall cabinets, ventilation Before installing the appliance, housing units, vent flues or above read all of the information contained kitchen islands. in this chapter and also in the ...
Page 35
Installation a 1 collar for exhaust ducting 6" / 150 mm. b 1 reducing collar for exhaust ducting 5" / 125 mm. c 1 non-return flap for fitting into the exhaust socket on the motor unit (not needed for recirculation mode). d Conversion kit for recirculation 4 x M5 x 40 mm (1 5/8") screws, 4 mode (the conversion kit is not...
Page 37
Installation a The ducting can also be connected at the back. b The ventilation hood is secured in the cut-out by clamps. This requires that the installation surface is made of a solid material, such as wood. Make sure that the material is strong enough to bear the weight of the ventilation hood and the edge extraction panel.
Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
Installation Installation recommendations – Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. – To achieve optimal vapor extraction, make sure that the hood covers the cooktop. The hood should be positioned centrally over the cooktop, not to the side or rear.
Exhaust duct – Make sure that all connections are WARNING: Danger of toxic fumes. secure and airtight. Gas cooking appliances release carbon monoxide that can be Remember that any constriction of harmful or fatal if inhaled. the airflow will reduce extraction To reduce the risk of fire and to performance and increase operating properly exhaust air, the exhaust...
Exhaust duct Reducing Collar (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max.
CSA C22.1-12, please consult a licensed electrician Canadian Electrical Code, Part I. or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
Activating Con@ctivity 2.0 Activating the ventilation hood Installation of the Con@ctivity 2.0 stick The cooktop and ventilation hood must be turned off. In order for you to be able to use the Con@ctivity 2.0 function, the cooktop Press and hold the delayed shutdown must be equipped with a Con@ctivity button 515 for approx.
Activating Con@ctivity 2.0 Activating the cooktop Activation failed While the ventilation hood is If a wireless connection cannot be searching for a wireless connection, established despite activation of the start activation on the cooktop. Con@ctivity function on the More information can be found in the ventilation hood and cooktop, the operating instructions for the...
Miele This service is available in USA only. dealer or Miele Technical Service. The telephone number for Miele is listed MieleCare, our Extended Service at the back of these instructions. Contract program, gives you the...
Technical data Fan motor 350 W Overhead cooktop lighting 4 x 3 W Total connected load 362 W Voltage, frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 2.5 ft (0.75 m) Weight 30.8 lbs (14 kg) Optional accessories for recirculation mode: Charcoal filter set DKF 19-1.
Caring for the environment Disposal of the packing Disposal of your old appliance material Do not dispose of this appliance with your household waste. The cardboard box and packing materials protect the appliance during Old appliances may contain materials shipping. They have been designed to that can be recycled.
Page 51
Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive Phone: 800-843-7231 Vaughan, ON L4K 4V8 609-419-4298 Fax: www.miele.ca www.mieleusa.com...