Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface SINUMERIK 808D documentation The SINUMERIK 808D documentation consists of the following components: ● Operating Instructions – Mechanical Installation Manual – Electrical Installation Manual – PLC Subroutines Manual – Function Manual – Parameter Manual ● Diagnostics Manual ● Commissioning Manual ●...
Page 4
The EC Declaration of Conformity for the EMC Directive can be found on the Internet at http://support.automation.siemens.com. Here, enter the number 15257461 as the search term or contact your local Siemens office. Licensing provisions The SINUMERIK 808D software is protected by national and international copyright laws and agreements.
Otherwise, you may suffer property loss. Make sure that the PPU, the MCP and the cables received correspond with the specific package you ordered from Siemens. Transport and storage Note Transport and storage should meet specified environmental conditions.
Page 8
Safety instructions Mechanical installation DANGER Death or serious injury from electric shock The equipment which is not diconnected from the mains or properly protected contains hazardous voltage. Such a voltage may lead to death or serious injury. Before installing or removing the components of the control system, make sure that the system is disconnected from the mains.
Page 9
Note Clear the manufacturer password before the machine is delivered; otherwise, end users can start the controller with the standard data, which can initialize the SINUMERIK 808D control system. As a consequence, the machine will not run. Carrying out of repairs...
System overview System overview The SINUMERIK 808D is an economical CNC solution for milling and turning machines. The turning variant of the control system can control up to two feed axes and one spindle. If configured with a software option for the "additional axis" function, it can additionally control an axis that serves as either a rotary axis or a linear axis.
Page 12
System overview Legend Name Order number PPU141.1, turning 6FC5370-1AT00-0AA0 (English) 6FC5370-1AT00-0CA0 (Chinese) PPU141.1, milling 6FC5370-1AM00-0AA0 (English) 6FC5370-1AM00-0CA0 (Chinese) 6FC5303-0AF35-0AA0 (English) 6FC5303-0AF35-0CA0 (Chinese) Setpoint cable PPU141.1 to CPM60.1 6FC5548-0BA00-1AF0 (5 m) 6FC5548-0BA00-1AH0 (7 m) 6FC5548-0BA00-1BA0 (10 m) SINAMICS V60 Controlled Power Module 6SL3210-5CC14-0UA0 (4 A) (CPM60.1) 6SL3210-5CC16-0UA0 (6 A)
Page 13
6FX6002-2LE00-1BA0 (10 m) Inverter or servo spindle drive From Siemens or a third-party manufacturer System structure The structure of the SINUMERIK 808D control system is shown as follows: ● CNC Unit – Panel Processing Unit (PPU) – Machine Control Panel (MCP) –...
Connecting 3.2 Connection Overview for SINUMERIK 808D Connection Overview for SINUMERIK 808D Electrical Installation Manual Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0...
Page 18
Connecting 3.2 Connection Overview for SINUMERIK 808D Note • The 24 V signal of X200 must be connected; otherwise, the communication between the PPU and the drives does not function as it should. • For the turning variant, connection to X52 is optional and depends upon whether you use the software option "additional axis".
Connecting 3.3 Connecting the interfaces on the PPU Connecting the interfaces on the PPU 3.3.1 Digital input interfaces - X100, X101, X102 Type Mini Combicon 10-pin Cable Max. length: 10 m Max. cross-section: One cable per connection: ≥ 0.5 mm2 Inputs Permissible level (including ripple) High level: 18 V - 30 V...
Page 20
Connecting 3.3 Connecting the interfaces on the PPU Table 3- 2 Pin assignment of X101 (DIN1) Interface Signal Comment N.C. Not assigned I1.0 Digital input I1.1 Digital input I1.2 Digital input I1.3 Digital input I1.4 Digital input I1.5 Digital input I1.6 Digital input I1.7...
Connecting 3.3 Connecting the interfaces on the PPU Connecting End sleeves are necessary if you use two cables per connection. Fasten the cables to the screw terminals and plug the terminals into interfaces X100, X101 and X102 correctly. 3.3.2 Digital output interfaces - X200, X201 Type Mini Combicon 10-pin Cable...
Connecting 3.3 Connecting the interfaces on the PPU Table 3- 5 Pin assignment of X201 (DOUT1) Illustration Signal Comment +24V +24V input (20.4 - 28.8 V) Q1.0 Digital output Q1.1 Digital output Q1.2 Digital output Q1.3 Digital output Q1.4 Digital output Q1.5 Digital output Q1.6...
Page 23
Connecting 3.3 Connecting the interfaces on the PPU Table 3- 6 Pin assignment of X21 (FAST I/O) Illustration Signal Comment +24 V +24 V input (20.4 - 28.8 V) NCRDY_1 NCRDY contact 1 NCRDY_2 NCRDY contact 2 Digital input Digital input BERO_SPINDLE or DI3 Spindle bero or digital input Fast output...
Connecting 3.3 Connecting the interfaces on the PPU Connection cables End sleeves are necessary if you use two cables per connection. Fasten the cables to the screw terminals and plug the terminal into the interface X21. You can buy the shielded cables from a third-party manufacturer. 3.3.4 Distributed I/O - X301, X302 Pin assignment...
Page 25
Connecting 3.3 Connecting the interfaces on the PPU Table 3- 7 Pin assignment of X301 (DISTRIBUTED I/O 1) Signal Comment Signal Comment MEXT External ground I5.7 Digital input +24V +24V output Not assigned I3.0 Digital input Not assigned I3.1 Digital input Not assigned I3.2 Digital input...
Page 26
Connecting 3.3 Connecting the interfaces on the PPU Table 3- 8 Pin assignment of X302 (DISTRIBUTED I/O 2) Signal Comment Signal Comment MEXT External ground I8.7 Digital input +24V +24V output Not assigned I6.0 Digital input Not assigned I6.1 Digital input Not assigned I6.2 Digital input...
Page 27
Connecting 3.3 Connecting the interfaces on the PPU CAUTION Be sure not to connect the pin 2 of X301/302 to ground; otherwise, the CNC controller or the power supply could be damaged! Note The 24 V output of X301/302 pin 2 comes from pins 47 to 50. Note Addressing ranges X301: IB3, IB4, IB5, QB2, QB3...
Page 28
Connecting 3.3 Connecting the interfaces on the PPU Digital outputs The diagram below shows you how to connect the connector pins of the digital outputs at interface X301 (example). You can connect connector X302 in the same way. To supply the digital outputs, you must connect an external 24 V DC power supply (X301, X302: pins 47, 48, 49, 50).
Connecting 3.3 Connecting the interfaces on the PPU 3.3.6 Pulse drive interfaces - X51, X52, X53 Pin assignment Type Sub-D, 15-pin, male Cable Type: drive cable Max. length: 10m Illustration Signal Comment PULSE+ PULSE, to drive side DIR+ DIRECTION, to drive side ENA+ ENABLE, to drive side BERO...
Page 31
10 A for 4 A or 6 A version of the drive; rated voltage: 250 VAC) to protect the system. As mentioned before, the SINUMERIK 808D control system can control three axes (X axis, Y axis and Z axis). To do so, you need to connect the control system via the three pulse drive interfaces (X51: X axis, X52: Y axis and X53: Z axis) separately to three SINAMICS V60 drives.
Page 32
Connecting 3.3 Connecting the interfaces on the PPU The connected motors are SIEMENS 1FL5 servo motors. SINUMERIK For further information about SINAMICS V60 and 1FL5 servo motors, refer to 808D Mechanical Installation, SINAMICS V60 Getting Started 1FL5 Motor Data sheet...
Connecting 3.3 Connecting the interfaces on the PPU 3.3.7 Analog spindle interface - X54 Interface X54 is for connecting the CNC controller to the inverter or servo spindle drive. Type 9-pin, Sub-D, female Cable Max. length: 10m Table 3- 10 Pin assignment of connector X54 (SPINDLE) Illustration Signal...
Page 34
Connecting 3.3 Connecting the interfaces on the PPU Figure 3-3 Connecting the inverter or the servo spindle drive (unipolar) Figure 3-4 Connecting the inverter or the servo spindle drive (bipolar) Electrical Installation Manual Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0...
Connecting 3.3 Connecting the interfaces on the PPU 3.3.8 Spindle encoder interface - X60 Type Sub-D, 15-pin, female Cable Type: encoder cable Max. length: 10m Table 3- 11 Pin assignment of X60 (SP ENCODER) Illustration Signal Comment Not assigned Not assigned Not assigned +5 V power supply Not assigned...
Connecting 3.3 Connecting the interfaces on the PPU 3.3.9 RS232 interface - X2 You can connect a PC/PG to the SINUMERIK 808D via an RS232 port for communication purposes. Type Sub-D, 9-pin, male Cable Type: RS232 Max. length: 10m Table 3- 12...
The cable set offered as accessories provides maximum interference immunity. 3.3.10 Power supply interface - X1 The SINUMERIK 808D uses a DC 24 V power supply. You can connect the DC 24V power supply via interface X1. Type Combicon 4-pin Cable Max.
Connecting 3.3 Connecting the interfaces on the PPU 3.3.11 USB interface on the front cover of the PPU Type USB socket, type A Cable Type: USB1.1 cable Max. length: 3m Illustration Signal name Signal type Comment P5_USB0 5V power supply DM_USB0 USB data- DP_USB0...
Connecting 3.3 Connecting the interfaces on the PPU 3.3.13 Battery interface A battery has been pre-assembled on the back cover of the PPU. The battery is not connected when delivered. You must plug the battery connector into the battery interface by yourself before switching the controller on. You can access it after removing the maintenance door: ①...
Connecting 3.4 Connecting the USB interface on the MCP 3.3.14 Slot for the system CompactFlash Card (CF card) CompactFlash card The system CompactFlash Card (CF card) has been pre-assembled on the back cover of the PPU. ① ② Maintenance door CF card Note Do not touch or remove the system CompactFlash Card (CF card) under any conditions!
Technical specifications Design data Dimensions (W x H x D) (in mm) 420 x 200 x 104 420 x 120 x 58 Weight (in kg) 3.06 0.86 Cooling method Self-cooling Self-cooling Degree of protection Front side: IP54 Front side: IP54 Back side: IP20 Back side: IP00 Electrical data...
You must consider interference radiation for the complete system. Particular attention should be paid to cabling. Contact your sales representative for assistance and support. If compliance with limit value class C2 is required, contact your local Siemens sales partner. Electrical Installation Manual...
Appendix ESD Directive A.1.1 What does ESD mean? Definition All electronic modules are equipped with highly integrated modules or components. Based on their design, these electronic components are highly sensitive to overvoltage and thus to discharge of static electricity. These Electrostatic Sensitive Devices/Modules are commonly abbreviated ESD. The common international designation ESD stands for Electrostatic Sensitive Device.
Appendix A.1 ESD Directive A.1.2 Electrostatic Discharge to Persons Charge Any person with a non-conductive connection to the electrical potential of his or her surroundings may be exposed to electrostatic charge. The following figure shows the maximum electrostatic voltage which can build up on a person coming into contact with the materials indicated.
Appendix A.3 FAQs FAQs FAQ 1 There is no output at the digital output interfaces Answer • Check whether you have connected the 24 V DC power supply or not. • Check PLC signals FAQ 2 Black screen Answer • Check whether you have correctly connected the 24 V DC power supply or not. •...