Ceiling & floor type air conditioner

Advertisement

Quick Links

Ceiling & Floor Type Air Conditioner
SVC MANUAL(Exploded View)
MODEL : LV-C362FLA0
LV-C422FLA0
LV-C482GLA0
LV-C602HLA0
LV-C48BGLA0
LV-C60BHLA0
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com

Advertisement

Table of Contents
loading

Summary of Contents for LG LV-C362FLA0

  • Page 1 Internal Use Only http://biz.lgservice.com Ceiling & Floor Type Air Conditioner SVC MANUAL(Exploded View) MODEL : LV-C362FLA0 LV-C422FLA0 LV-C482GLA0 LV-C602HLA0 LV-C48BGLA0 LV-C60BHLA0 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
  • Page 2: Table Of Contents

    Air Purging of the Connecting Pipes and the Indoor Unit..........31 Operation ..........................32 3-way Valve ..........................33 Cycle ............................38 Troubleshooting ........................41 Exploded View ........................43 - 2 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 3: Functions

    Auto Operation • The setting temperature, indoor fan speed and desired operation made are automatically set by fuzzy rule. - 3 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 4 : 1, 2, 3, 4, 5, 6, 7hr, Off Timer Airflow Direction Control Fan Operation Mode : Fan Operates without cooling. (Cooling model only) Reset - 4 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 5: Product Specifications (Cooling Only)

    Packing Dimension Indoor(W*H*D) inch(mm) 1635/751/293 1635/751/293 1635/751/358 Outdoor(W*H*D) inch(mm) 40.2*34.2*17.3(1020*870*440) 42.1*52.1*19.5(1070*1300*495) 42.1*52.1*19.5(1070*1300*495) Stuffing Quantity With(Without) S/Parts 20/40ft 34/76 22/48 21/45 - 5 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 6 Packing Dimension Indoor(W*H*D) inch(mm) 1635/751/378 1635/751/358 1635/751/378 Outdoor(W*H*D) inch(mm) 42.1*52.1*19.5(1070*1300*495) 42.1*52.1*19.5(1070*1300*495) 42.1*52.1*19.5(1070*1300*495) Stuffing Quantity With(Without) S/Parts 20/40ft 21/44 21/45 21/44 - 6 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 7: Dimensions

    (1) Indoor Unit Dimension Capacity 36K BTU/h 1550 1362 42K BTU/h 1550 1362 48K BTU/h 1550 1362 60K BTU/h 1550 1362 - 7 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 8 (2) Outdoor Unit (36K) (42K/48K/60K) MODEL W(mm) H(mm) 1,220 1,220 1,220 D(mm) - 8 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 9: Refrigeration Cycle Diagram

    Refrigeration Cycle Diagram • COOLING ONLY (LV-C362FLA0, LV-C422FLA0, LV-C482GLA0, LV-C602HLA0, LV-C48BGLA0, LV-C60BHLA0) INDOOR UNIT OUTDOOR UNIT LIQUID SIDE CAPILLARY TUBE HEAT HEAT EXCHANGER EXCHANGER (CONDENSER) (CONDENSER) COMPRESSOR GAS SIDE *Additional Pipe size(Diameter: ø) Piping length(m) Elevation(m) MODEL refrigerant Liquid Rated Max.
  • Page 10: Wiring Diagram

    SOCKET SOCKET BLOWER Ground MOTOR 1(L) 2(N) White Wire Run Cap. Brown Wire POWER SUPPLY COMP(A) COMP(B) 1Ø,220V,60Hz~ 3854A20135S - 10 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 11 GN/YL TERMINAL BLOWER Ground BLOCK MOTOR White Wire Run Cap. Brown Wire T1 T2 T3 MOTOR MOTOR COMP. 3854A20026J - 11 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 12 YL BK YL BK Ground BLOWER MOTOR White Wire 49FMo 49FMo (T1) (T2) Run Cap. (T3) Brown Wire GN/YL 3854A20119T - 12 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 13: Operation Details

    More than More than 3 minutes 3 minutes Selecting Selecting Selecting INDOOR FAN fan speed fan speed fan speed COMPRESSOR - 13 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 14 30°C 30°C Intake-Air temp Setting Temp. +0.5°C (Compressor OFF) Setting Temp.-0.5°C (Compressor ON) Fuzzy Speed Indoor Fan Compressor - 14 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 15 : LOW : COMP ON : COMP OFF GRAPH of Natural wind by the CHAOS logis (During Cooling operation) - 15 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 16 • If no input by the remote controller or no switching of the slide switch within 7 hr after the appliance operates by the Auto Restarting operation, the appliance is forced to stop at the moment of 7-hr elapse. - 16 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 17 For normal operation after checking by test mode, you should press SW1 nine times for resetting or reconnect the power cord. - 17 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 18: Installation Of Indoor, Outdoor Unit

    • Capacity is based on standard length and maximun allowance length is on the basis of reliability. • Improper refrigerant charge may result in abnormal cycle. - 18 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 19 • A place where the unit can withstand its vibration. Suspension bolts • A place where service can be easily performed. Spring washer Max. 12mm Washer - 19 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 20 Step1: Remove screw Step1 Step2: Lift side-panel upward slightly Step3: To move side panel along arrow as shown. Step2 Step3 - 20 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 21 Side of view • The unit must be declined to the bottomside of the unit when finished installation. Ceiling - 21 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 22 • Gas leakage ....Is the piping connection correctly? • Wiring ......Is the wiring connection correctly? • Lock-bolt......Is the lock-bolt of compressor loosened? - 22 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 23 Above 30Cm Above 50Cm Above 70Cm Keep a maintenance space Face of wall - 23 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 24 Control terminal board the earthing terminal provided in the control box and do earthing. Please check !! Cord clamper Cover control - 24 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 25: Connecting Pipes To The Indoor Unit

    = Improper flaring = Inclined Surface Cracked Uneven damaged thickness Even length all round - 25 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 26 (Nitrogen gas: Supply pressure 0.05~0.1kg/cm b. When supplying inert gas, be sure to open one end of piping. Water enters Plaster enters - 26 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 27: Connecting Pipes To The Outdoor Unit

    • Spray one or two glasses of water upon the evaporator. • Ensure that water flows drain hose of indoor unit without any leakage. - 27 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 28: Connecting Cables Between Indoor Unit And Outdoor Unit

    If the supply cord is damaged, it must be replaced by a special cord or assembly availible from the manufacturer of its service agent. - 28 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 29 • Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal func- tion of a overload protection device. • Proper starting power is not given to the compressor. - 29 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 30 4. Fix the pipings onto the wall by saddle or equivalent. - 30 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 31: Air Purging Of The Connecting Pipes And The Indoor Unit

    Liquid side Indoor unit Closed Outdoor unit 2-way valve/ 3-way valve Gas side 3-way valve Closed Vaccum pump OPEN CLOSE - 31 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 32: Operation

    ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. RESET BUTTON Used prior to resetting time or after replacing batteries. - 32 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 33: 3-Way Valve

    – Open the low-pressure valve on the charge set slightly to air purge from the charge hose. (5) Set the liquid side valve to the closed position. - 33 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 34 – Close the valve on the gas cylinder and discharge the refrigerant until the gauge indicates 3 to 5 kg/cm - 34 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 35 – Discharge the refrigerant gradually; if it is discharged too suddenly, the refrigeration oil will also be discharged. - 35 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 36 (4) Disconnect the charge hose from the vacuum pump. – Vacuum pump oil. If the vacuum pump oil becomes dir ty or depleted, replenish as needed. - 36 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 37 1 minute and then repeat the procedure (pumping down-pin). - 37 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 38: Cycle

    (9) Open the liquid side completely first and then the pipe connection is ok or not. gas side fully in order. - 38 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 39 (5) After the needle of gage indicates below 0 kgf/cm , close the valve of gas side quickly and turn off the power. - 39 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 40 1 minute and then repeat the procedure. - 40 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 41: Troubleshooting

    8. Indoor up-down louver Handset control Change function will not function Faulty stepping motor Replace Connector plug Replace or repair - 41 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 42 Faulty indoor sensor Replace PCB faulty Replace Indoor fan not working Replace Low gas charge Replace Add gas and leak test - 42 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 43: Exploded View

    148000A 132100A 132100B 249310 359012A 145200 W48300 147581A 147590 359012B 147582 336610 147581B 330871 235450 346810 268711 152302 135303 - 43 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 44 146811 132100A 148000A 132100B 249310 359012 145200 W48300 147581A 147590 147582 147581B 336610 235450 330871 346810 268711 152302 135303 - 44 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 45 148000B 146811 132100A 148000A 132100B 249310 359012 145200 W48300 147581A 147590 147582 147581B 336610 330871 346810 268711 152302 135303 - 45 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 46 4. Outdoor Unit • Models: LV-C362FLA0 - 46 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 47 5. Outdoor Unit • Models: LV-C422FLA0, LV-C482GLA0, LV-C602HLA0, LV-C48BGLA0, LV-C60BHLA0 - 47 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 48 6. Outdoor Unit • Models: LV-C422FLA0, LV-C482GLA0, LV-C602HLA0, LV-C48BGLA0, LV-C60BHLA0 - 48 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 49 February, 2008 P/NO : 3828A20172X...