Page 2
New users Infrared (IR) Transceivers may wish to create a model of the venue Each time a user powers on an AC6 array, the and ask the AC6 system to recommend array modules immediately use the IR transceivers configurations based on available inventory.
Page 3
Using the Loudspeaker Users will need to perform the following EAW Resolution 2 software is designed to general tasks to properly put the AC6 into use. control ADAPTive systems. For advanced This manual includes details for each task. functions like in-venue optimization, supplemental software such as Rational 1.
Page 4
The second image demonstrates what would happen with the same frequency in the same venue but with an AC6 array of 2x modules instead of 1x. It is quite clear how much more directive the vertical has become in this image and if we continue to add modules to the array, the effect will become more pronounced.
Quickstart Guide Finally, we see the result when 4x AC6 is deployed. This array of AC6 produces an extremely tight vertical pattern at 125Hz across this listening area. If directivity at lower frequencies is required for the application, array length must be considered.
Page 6
X 80' - SEATING CAPACITY 510 PEOPLE) Quickstart Guide AUDITORIUM (70' X 80' - SEATING CAPACITY 510) Perspective Equipment List 4x AC6 2x SBX218 1x MKD1096 4x JF60z 1x UXA4410 Elevation Plan THEATER (70' X 75' - SEATING CAPACITY 670 PEOPLE)
Page 7
Plan Going Online with AC6 Before going online, be sure the computer AC6 devices on the network and displays them is connected to the same Ethernet network in the Online Devices list. This list will include as the networked loudspeaker system.
Page 8
AC6 in a single system. This will ensure you know how the vertical column for example, those will be Arrays will need to be configured.
Page 9
Arrays will be shown with the modules in Columns and the meters. A physical AC6 Array in the Online Devices list can be assigned or associated with a modeled Array in the model by simply clicking on the Array in the list and dragging it on to the appropriate modeled Array.
Page 10
Double clicking the teal input assignment button will open the Array Configuration dialog. Right clicking a module in an Array will open a menu with options to Insert Item Above, Insert Item Below, Unassign, or Remove Array Item. Tel 800 992 5013 / +1 508 234 6158 www.eaw.com...
Page 11
Quickstart Guide Double clicking a module will open the Diagnostics Window for that module Updating Firmware on AC6 NOTE: Before starting Firmware update, please turn the Windows Firewall off. NOTE: It is highly recommended you run the firmware update with a DHCP server connected to the network.
Page 12
Quickstart Guide Select the firmware file (.eawfw) in C:\ProgramData\EAW Resolution (Windows must be set to show hidden files and folders): Tel 800 992 5013 / +1 508 234 6158 www.eaw.com...
Page 13
Quickstart Guide Select the AC6 modules you wish to upgrade (or select all): Select Upgrade Firmware. The upgrade is complete when the status indicates ‘Finished’. The status will return to ‘Ready’ about 30 seconds after it has finished. Mounting & Rigging AC6 IMPORTANT SAFETY INSTRUCTIONS –...
Page 14
Quickstart Guide 3. Installation of AC6 wall bracket to mounting surface a. The wall bracket must be mounted to secure structure sufficient to support the products weight. If you are unsure, please consult a qualified professional. A minimum of two attachment points...
Page 15
Quickstart Guide 4. Installation of cabinet bracket to the AC6 unit a. Using the desired cabinet orientation (input on bottom, or top), and desired pan direction (left or right) identify which side of the cabinet to mount the bracket. b. The bracket must be mounted on the side in which the pan is required.
Page 16
Refer to user manual for more information. c. Starting from the bottom of the array and moving to the top, mount each AC6 to the respective wall bracket. Attaching AC6 to wall bracket e. Lift the cabinet up to the mounting bracket and lock each plunger into the wall bracket.
AC6 Cabinet Bracket Assembly 2. AC6 wall bracket limits of use a. The AC6 flush mount bracket is designed to suspend each corresponding AC6 Series loudspeaker with a design factor of 10:1 to meet or exceed most global suspension regulations. Below are the maximum working load limits at 10:1, 7:1 and 5:1 Design Factors.
Page 18
The AC6 Flush Mount bracket is designed to suspend only one loudspeaker per bracket. d. Any geometric or structural modifications to the AC6 Flush Mount Bracket or hardware are not EAW-approved will void the warranty and may result in damage, injury, or death.
Page 19
(left, right, top) identify position of the bracket on AC6. Note position on flytrack as this will need to remain uniform for all AC6 in column. b. The bracket must be mounted in the orientation in which they should be connected.
Page 20
Network, analog audio, and dry contacts can be looped from either end. Refer to user manual for more information. c. Using pre-wired cabling, wire the AC6 unit in both upper and lower locations. d. If WP covers are being used, install the covers at this stage.
Page 21
2. Using steps above, attach AC6 cabinet bracket for flush mount. a. Lay down AC6 on a padded surface. 3. Attach stinger to AC6 using M10 bolts (Install) or knobs (portable). a. C-Clamp may also be used on cabinet bracket.
Page 22
Quickstart Guide 4. Attach 1/2" shackle to stinger or mohawk 5. Suspend AC6 Tel 800 992 5013 / +1 508 234 6158 www.eaw.com...
Page 23
1. Place AC6 Upside down. 2. Remove M5 Screws from bottom. 3. Attach Pole cup adapter with M5x20 screws, lock washer, and large flat washer. 4. Using (2) people, place AC6 on speaker stand. M6 screws removed Pole cup attachement AC6 on stand Tel 800 992 5013 / +1 508 234 6158 www.eaw.com...
Page 24
As with any professional loudspeaker system, routine maintenance must be conducted in order to ensure the longevity and safe, consistent performance. d. Inspect the AC6 Wall Bracket for corrosion and other damage. Brackets with visible damage should be replaced and discarded.
Page 25
• Identify if covers will be fitted before or after mounting (refer to mount instructions) 2. Based on the quantity of AC6 modules determine the quantity of covers required: • 2X End Cover – (1) per array •...
Page 26
(not included) should be fitted to each knockout prior to installing cables. • Silicone sealant should be used as needed to make any cable connections water tight. Tel 800 992 5013 / +1 508 234 6158 www.eaw.com...