hit counter script

Advertisement

Quick Links

MD2000 Laser Barcode Scanner
User Manual
Version: MD2000_UM_EN_V1.1.5

Advertisement

Table of Contents
loading

Summary of Contents for Panda MD2000

  • Page 1 MD2000 Laser Barcode Scanner User Manual Version: MD2000_UM_EN_V1.1.5...
  • Page 2: Notice

    Notice Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. Make sure you carefully read the following information to ensure that your barcode scanner is able to perform at the designed level. All software, including firmware, furnished to the user is on a licensed basis. The right is reserved to make changes to any software or product to improve reliability, function, or design.
  • Page 4: Table Of Contents

    Contents Notice ..............................i Contents ..............................iii 1 Specifications ............................. 1 1-1 Technical specifications ......................1-2 Default settings for various types of barcode ................1-3 Decode zone ..........................2 Get started ............................4 2-1 Electrical interface/Pin assignment ..................... 2-2 Dimensions ..........................2-3 Parts of the scanner ........................
  • Page 5 3-8 UPC-E ............................3-9 UPC-E1 ............................. 3-10 EAN-13 (ISBN/ISSN) ......................34 3-11 EAN-8 ............................. 36 3-12 Code 39 (Code 32, Trioptic Code 39) ..................38 3-13 Interleaved 2 of 5 ........................41 3-14 Industrial 2 of 5........................43 3-15 Matrix 2 of 5 ..........................44 3-16 Codabar ..........................
  • Page 7: Specifications

    1 Specifications 1-1 Technical specifications Table 1-1 Technical specifications @25°C Input voltage 5 VDC ± 0.25 V 150 mW (Standby); 525 mW (Operating); 850 mW (Max.) Power Current 30 mA (Standby); 105 mA (Operating); 170 mA (Max.) Laser 630-650 nm laser diode 200 times/sec Decoding rate ±65°, ±70°, ±42°...
  • Page 8: Default Settings For Various Types Of Barcode

    Laser safety: EN60825-1, Class 1 EMC: EN55022, EN55024 Electrical safety: EN60950-1 Safety Drop resistance: 30+ times 2.0 m (6.5 ft) drops to concrete Protection class: IP50 1-2 Default settings for various types of barcode Table 1-2 Default settings Read Check Check digit transmission Min.
  • Page 9: Decode Zone

    √ (16) DataBar √ DataBar (16) Truncated √ (16) DataBar Limited √ DataBar Expanded Note: The settings for ISBN/ISSN and EAN-13 must be the same except the code ID. Fixed-length barcodes. 1-3 Decode zone Figure 1-1 Decode zone @25°C, scan angle: 55° Table 1-3 Description of barcode patterns applied in Figure 1-1 The settings for GS1 DataBar Truncated and GS1 DataBar must be the same.
  • Page 10: Get Started

    Wide-narrow Resolution Barcode type Barcode content Contrast element ratio 3 mil Code39 2.5:1 4 mil Code39 123456789 2.5:1 5 mil Code39 2.5:1 10 mil Code39 2.5:1 13 mil 100%UPC 123456 15 mil Code39 2.5:1 20 mil Code39 2.5:1 30 mil Code39 2.5:1 2 Get started...
  • Page 11: Dimensions

    Table 2-1 Electrical interface/Pin assignment RS232 cable USB cable Power(+5V) Power(+5V) Reseved Reseved Ground Ground +3.3V Ground (for interface auto selection purpose) (for interface auto selection purpose) Reserved Reserved Ground (Shell) Ground (Shell) TRIGGER TRIGGER Note: Voltage level of all RS232 Pin-outs (RXD, TXD, CTS and RTS) is 0V for logic low level and 3.3V for logic high level.
  • Page 12: Parts Of The Scanner

    Figure 2-2 Dimensions 2-3 Parts of the scanner Figure 2-3 Parts of the scanner ① LED ② Beeper ③ Exit window ④ Trigger ⑤ Release-hole of the cable ⑥ Cable interface port...
  • Page 13: Introduction To Installation

    2-4 Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper connections. Go through all steps again. 2-4-1 Installation - RS-232 1. Connect the RS-232 interface cable to the bottom of the scanner. 2.
  • Page 14: Assembling The Stand

    Figure 2-6 Find the release-hole. Insert a thin wire into the hole and pull out the cable gently. 2-5 Assembling the stand Note: The stand is an optional accessory. See the figure above, tighten the screws. Bend the neck to the desired position for scanning. Screw mounting: Screw one #10 wood screw into each screw-mount-hole until the base of the stand is secured.
  • Page 15: Scanning

    2-6 Scanning When the scanner is scanning, ensure the laser beam crosses every bar and space of the barcode. See Figure 2-7. √ × Figure 2-7 2-7 Auto-detection Note: Auto-detection and stand are optional accessories. To scan a barcode, present the bar code and ensure the scan line crosses every bar and space of the symbol.
  • Page 16 DIS- A utoDete EN- A utoDete Figure 2-9...
  • Page 17: Parameter Menus

    3 Parameter menus 3-1 Introduction This section describes the programmable parameters, provides barcodes for programming. The scanner is shipped with the factory default settings as described in this chapter. These factory-default- settings values are stored in flash memory and are preserved even when the scanner is powered down. Changes to the factory default values can be stored as custom defaults.
  • Page 18: Example: Configure Scanner

    3-2 Example: configure scanner Note: The factory default settings are indicated with asterisks (*) in this manual. 1、 Single-scan setting Scan the appropriate Single-scan setting barcode according to the user’s demand. Example: Set Flow control to be none. Steps: Scan the following barcode. 2、...
  • Page 19: Rs232 Interface

    Figure 4-4 3-3 RS232 interface Flow control: None- The communication only uses TXD and RXD signals without any hardware or software handshaking protocol. RTS/CTS- If the scanner requests to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
  • Page 20 timeout, the scanner will issue an error indication. By setting (Host idle: Low RTS or Host idle: High RTS), the scanner can be set to match the Serial Host RTS line. ACK/NAK- If Decode data packet format is set to Packeted, after barcode data transmitted, the scanner expects either an ACK (acknowledge) or NAK (not acknowledge) response from the host.
  • Page 21 1200 2400 4800 9600 19200 38400 57600 Baud rate 115200 None Parity SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Even Data bit 8 bits 1 bit Stop bit 2 bits 01-99 Host-character delay 01-99 (10ms)
  • Page 22: Usb Interface

    Decoded data packet format Packeted 3-4 USB interface USB device type: HID keyboard– By setting, the scanner is used as a USB HID keyboard emulation device. USB virtual COM– By setting, the scanner emulates a USB virtual COM device. If a Microsoft Windows PC is connected to the scanner, a driver is required to install on the connected PC.
  • Page 23 HID keyboard for Apple Mac USB virtual COM Turkish F Turkish Q French Italian Spanish Slovak Denmark Japanese German Belgian Keyboard layout Russian 0 ms 5 ms Inter-character delay 10 ms SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value...
  • Page 24 20 ms 40 ms 60 ms Alphabetic key Numeric keypad Numeric key Alt + keypad...
  • Page 25: Scan Trigger Mode & Some Global Settings

    3-5 Scan trigger mode & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed.
  • Page 26 Global Max./Min. code length: These two lengths are defined as the valid range of decoded barcode data length. Make sure that the minimum length setting is no greater than the maximum length setting, otherwise the labels of the symbol will not be readable. In particular, the same value can be set for both minimum and maximum reading length to force the fixed length barcode decoded.
  • Page 27 Alphanumeric character only- If this option is selected, the scanner will output the alphanumeric characters only, i.e. “A”-“Z”, “a”-“z”, “0”-“9”. Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction. This function is not effective for all types of barcodes. Scan angle: If narrow angle (40°) is selected, the decode rate is 1 time/scan;...
  • Page 28 Timeout off Auto-detection 01-99 Standby duration 01-99 (100ms) 00-FF 00-FF (100ms) (00: None) Same barcode delay time 00-09 00-09 Double confirm (00: None) 04-99 Global max. code length 04-99 01-99 Global min. code length 01-99 Global G1-G4 string selection 00-44 00-44 SETUP Multiple-scan setting...
  • Page 29 Disable Printable character only Character output restraint Alphabetic & Numeric only Disable Decoder optimization Enable Wide (56°) Scan angle Narrow (40°) 1 second 5 seconds 10 seconds 30 seconds 1 minute 3 minutes 10 minutes Note 2 Auto-sleep delay 30 minutes SETUP Multiple-scan setting Single-scan setting...
  • Page 30: Indication

    Never Disable “No read” response Enable Disable Deep sleep Enable ASCII UTF-8 Character encoding system Windows-1251 Note 1: This configure will not be changed when the scanner scans load default setting barcode. Note 2: The tolerance is ±20%. 3-6 Indication Power on alert: After power-on or restart, the scanner will generate alert signal (Beeper beeping and LED flashing).
  • Page 31: Upc-A

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Power on alert Enable Disable LED indication Enable Disable Beeper indication Enable 01-09 Beep tone duration 01-09 (25 ms) Middle Volume of beeper High 2.7KHz 2.5KHz Frequency of beeper 2.3KHz 3-7 UPC-A Read: Format...
  • Page 32 System character Data digits (10 digits) Check digit Check digit verification: The check digit verification is optional. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Code ID is a one-or-two-character string used to represent the symbol upon a succeeding reading.
  • Page 33 Option barcode Option Alpha. value Disable Check digit trans. Enable 00-FF 00-FF Code ID setting (ASCII) <A>* 00-44 00-44 Insert group selection (00: None) None 2 digits 5 digits Supplement digits 2 or 5 digits None Truncate leading zeros Expand to EAN-13 Truncate system character Truncation/Expansion Add country code...
  • Page 34 Format System character “0” Data digits (6 digits) Check digits Check digit verification: The check digit verification is optional. Check digit trans.: By setting Enable, check digit will be transmitted. UPC-A Code ID setting: Refer to Code ID setting of Insert group selection: UPC-A Refer to Insert group selection of...
  • Page 35 SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value 00-FF 00-FF Code ID setting (ASCII) <D>* 00-44 00-44 Insert group selection (00: None) None 2 digits 5 digits Supplement digits 2 or 5 digits None Truncate leading zeros Expand to EAN-13 Expand to UPC-A Truncate system character Truncation/Expansion...
  • Page 36 Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A UPC-A Insert group selection: Refer to Insert group selection of Supplement digits: Format System character “1” Data digits (6 digits) Check digit Supplement digits 2 or 5 Truncation/Expansion:...
  • Page 37 Option barcode Option Alpha. value 00-FF 00-FF Code ID setting (ASCII) <D>* 00-44 00-44 Insert group selection (00: None) None 2 digits 5 digits Supplement digits 2 or 5 digits None Expand to EAN-13 Expand to UPC-A Truncate system character Truncation/Expansion Add country code 3-10 EAN-13 (ISBN/ISSN)
  • Page 38 Data digits (12 digits) Check digit Supplement digits 2 or 5 ISBN/ISSN conversion: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for books and magazines. The ISBN is 10 digits with leading “978”...
  • Page 39: Ean-8

    00-FF 00-FF EAN-13 code ID setting (ASCII) <A>* 00-44 00-44 Insert group selection (00: None) None 2 digits 5 digits Supplement digits 2 or 5 digits Disable ISBN/ISSN conversion Enable Disable Ink Spreading Canceling Enable 00-FF 00-FF ISBN/ISSN code ID setting (ASCII) <B>* 3-11 EAN-8...
  • Page 40 Data digits (7 digits) Check digit Supplement Digits 2 or 5 Truncation/Expansion: Refer to Truncation/Expansio n of 3-7 UPC-A...
  • Page 41 SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF 00-FF Code ID setting (ASCII) <C>* 00-44 00-44 Insert group selection (00: None) None 2 digits 5 digits Supplement digits 2 or 5 digits...
  • Page 42: Code 39 (Code 32, Trioptic Code 39)

    3-12 Code 39 (Code 32, Trioptic Code 39) Read: Format Start character(*) Data digits (variable) Check digit (optional) End character(*) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.
  • Page 43 Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <M>* 00-44 00-44 Insert group selection (00: None) Standard Format Full ASCII Disable Start/End transmission Enable SETUP...
  • Page 44: Interleaved 2 Of 5

    Disable “*” as data character Enable Disable Convert Code 39 to Code 32 Enable Disable Code 32 Prefix “A” transmission Enable Disable Trioptic Code 39 read Enable Trioptic Code 39 Start/End Disable transmission Enable Note 1: If Trioptic Code 39 is set Enable, Code 39 is forced Enable. Note 2: If Code 39 is set Disable, Trioptic Code 39 is forced Disable.
  • Page 45: Industrial 2 Of 5

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification OPCC Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <I>* 00-44 00-44 Insert group selection...
  • Page 46: Matrix 2 Of 5

    Format Data digits (variable) Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of 3-12 Code 39 Code ID setting: Refer to Code ID setting of 3-7 UPC-A 3-7 UPC-A Insert group selection: Refer to Insert group selection of SETUP Multiple-scan setting...
  • Page 47 Data digits (variable) Check digit (optional) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. 3-12 Code 39 Max./Min. code length: Refer to Max./Min. code length of 3-7 UPC-A Code ID setting: Refer to Code ID setting of 3-7 UPC-A Insert group selection: Refer to Insert group selection of...
  • Page 48: Codabar

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <X>* 00-44 00-44 Insert group selection...
  • Page 49 Start character Data digits (variable) Check digit (optional) End character Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. 3-12 Code 39 Max./Min. code length: Refer to Max./Min. code length of 3-7 UPC-A Code ID setting: Refer to Code ID setting of 3-7 UPC-A...
  • Page 50: Code 128

    Multiple-scan setting Single-scan setting Option barcode Option Alpha. value 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <N>* 00-44 00-44 Insert group selection (00: None) ABCD/ABCD abcd/abcd ABCD/TN*E Start/End type abcd/tn*e Disable Start/End transmission Enable Disable Start/End character equality Enable 3-17 Code 128 Read:...
  • Page 51 Data digits (variable) Check digit (optional) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. 3-12 Code 39 Max./Min. code length: Refer to Max./Min. code length of Code ID setting: Refer to Code ID setting of 3-7 UPC-A 3-7 UPC-A Insert group selection: Refer to Insert group selection of...
  • Page 52 SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Reserved 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <K>* 00-44 00-44 Insert group selection...
  • Page 53: Ucc/Ean 128 (Gs1-128)

    3-18 UCC/EAN 128 (GS1-128) Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. Max. /Min. code length: Refer to Max. /Min. code length of 3-12 Code 39 3-7 UPC-A Code ID setting: Refer to Code ID setting of...
  • Page 54 SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Reserved 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <K>* 00-44 00-44 Insert group selection...
  • Page 55: Isbt 128

    3-19 ISBT 128 Read: Format Start character(“=” or “&”) Data digits (variable) Check digit (optional) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of 3-12 Code 39 3-7 UPC-A Code ID setting: Refer to Code ID setting of...
  • Page 56: Code 93

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Reserved 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <K>* 00-44 00-44 Insert group selection...
  • Page 57 Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. 3-12 Code 39 Max./Min. code length: Refer to Max./Min. code length of Code ID setting: Refer to Code ID setting of 3-7 UPC-A 3-7 UPC-A Insert group selection: Refer to Insert group selection of...
  • Page 58: Code 11

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <L>* 00-44 00-44 Insert group selection...
  • Page 59 Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, 1 or 2 check digits will be transmitted upon the selected check digit verification method. 3-12 Code 39 Max./Min. code length: Refer to Max./Min. code length of 3-7 UPC-A Code ID setting: Refer to Code ID setting of Insert group selection: Refer to Insert group selection of...
  • Page 60: Msi/Plessey

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable One digit Check digit verification Two digits Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <V>* 00-44...
  • Page 61 Format Data digits (variable) 1 or 2 check digits (optional) Check digit verification: The MSI/Plessey has one or two optional check digits. There are three methods to verify check digits, i.e. Mod10, Mod10/10 and Mod 11/10. 1 or 2 check digits will be calculated as the sum module 10 or 11 of the data digits.
  • Page 62 SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable 1 digit (Mod 2 digits (Mod 10/10) Check digit verification 2 digits (Mod 11/10) Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF...
  • Page 63: Plessey

    3-23 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The UK/Plessey has two optional check digits. The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted.
  • Page 64: China Post

    SETUP Multiple-scan setting Single-scan setting Option barcode Option Alpha. value Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF 00-FF Code ID setting (ASCII) <U>* 00-44 00-44 Insert group selection...
  • Page 65 11 Data digits 3-12 Code 39 Max. /Min. code length: . The code length of Refer to Max. /Min. code length China Post is Code setting: Refer UPC-A Code ID setting of Insert group selection: 3-7 UPC-A Refer to Insert group selection of SETUP Multiple-scan setting Single-scan setting...
  • Page 66: Telepen

    3-25 Telepen Read: Format Start character (_) Data digits (variable) Check digit End character (z) Check digit verification: The check digit verification is optional. Check digit transmission: By setting Enable, check digit will be transmitted. 12 Code 39 Max./Min. code length: Refer to Max./Min.
  • Page 67 SETUP Multiple-scan setting Alpha. Single-scan setting Option barcode Option entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 00-99 Max. code length 00-99 00-99 Min. code length 00-FF 00-FF Code ID setting <P>* 00-66 00-66 Insertion group selection Alphanumeric...
  • Page 68: Gs1 Databar (Gs1 Databar Truncated)

    3-26 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded as the same as the standard GS1 DataBar format, except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater than or equal to 33 modules.
  • Page 70: Gs1 Databar Limited

    3-27 GS1 DataBar Limited Read: Format 16 Data digits 3-7 UPC-A Code ID setting: Refer to Code ID setting of 3-7 UPC-A Insert group selection: Refer to Insert group selection of 3-26 GS1 DataBar (GS1 DataBar Truncated) Conversion: Refer to Conversion of SETUP Multiple-scan setting Single-scan setting...
  • Page 71 Data characters (variable) 3-7 UPC-A Code ID setting: Refer to Code ID setting of 3-7 UPC-A Insert group selection: Refer to Insert group selection of Conversion: UCC/EAN 128- Refer to Code ID transmission of 3-31 String transmission , ]Cm will be identified as AIM ID.
  • Page 72 Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Suffix string setting: The <enter > key is represented in different ASCII when it is applied by different OS. For a Windows/DOS OS, <enter> is represented as <CR><LF> (0x0D 0x0A); for an Apple MAC OS, <enter>...
  • Page 73 FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substituted with a defined string. Example: Set FN1 substitution string to be “ABCD”. “31 1D 32 1D 33 1D 34 1D 35” Original code data (hexadecimal) “31 41 32 42 33 43 34 44 35”...
  • Page 74: G1-G4 & Fn1 Substitution String Setting

    Postamble string setting 0-22 characters 00-FF (Default: None) Insert G1 string setting 0-22 characters 00-FF (Default: None) Insert G2 string setting 0-22 characters 00-FF (Default: None) Insert G3 string setting 0-22 characters 00-FF (Default: None) Insert G4 string setting 0-22 characters 00-FF (Default: None) 0-4 characters...
  • Page 75: String Transmission

    00-99 Insert G3 string position 00-99 00-99 Insert G4 string position 00-99 Before code data Code ID position After code data 3-31 String transmission Format of barcode data transmission: Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Prefix transmission: By setting Enable, prefix will be appended before the data transmitted.
  • Page 76 Multiple-scan setting Single-scan setting Option bar code Option Alpha. value Disable Prefix transmission Enable Disable Suffix transmission Enable Code name Disable transmission Enable Disable Preamble transmission Enable SETUP Multiple-scan setting Single-scan setting Option bar code Option Alpha. value Disable Postamble transmission Enable Disable Proprietary ID...
  • Page 77: Barcode Representing Non-Printable Character

    Disable Upper (data only) Lower (data only) Upper (whole string) Case conversion Lower (whole string) Disable FN1 substitution RS232 transmission USB/RS232 4 Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method of printing following barcode is different. 2.
  • Page 78: Ascii Table

    Delete 5 ASCII table Notes: The 2nd and the 3rd columns above are used for keyboard wedge only.
  • Page 79: Test Chart

    6 Test chart UPC-A UPC-E UPC-E1 EAN-13 ISBN/ISSN EAN-8 Code 39 Code 32 A908765439...
  • Page 80 Trioptic Code 39 Default setting: Disable Interleaved 2 of 5 Industrial 2 of 5 ( Default setting: Disable) Matrix 2 of 5 Codabar Code 128 UCC/EAN 128 ISBT 128...
  • Page 81 Test chart (continue) Code 93 Code 11 ( Default setting: Disable) MSI/Plessey ( Default setting: Disable) UK/Plessey China Post Telepen GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Limited GS1 DataBar Expanded...
  • Page 82: Return Default Parameters & Firmware Version

    7 Return default parameters & firmware version WARNING: Restore factory defaults If you wish to return the scanner to all the factory default settings, scan the barcode above. But Scanning mode remains unchanged. Write to customer defaults Write current parameter settings to the customer default settings. But Scanning mode remains unchanged.
  • Page 83: Configuration Alphanumeric Value Barcode (As Para. Value)

    Enable Auto-detection If you wish to enable Auto-detection, scan the barcode above. Disable Auto-detection If you wish to disable Auto-detection, scan the barcode above. Note: The Scanning mode will switch to momentary. 9 Configuration alphanumeric value barcode (as Para. value)
  • Page 84 To finish parameter setting, please scan the bar code below.

Table of Contents